Operating Manual XPD 500 Watt Series Programmable DC Power Supply XPD 7.5-67 XPD 18-30 XPD 33-16 XPD 60-9 XPD 120-4.5.
.
Operating Manual for XPD Series Programmable DC Power Supply.
ii Operating Manual for XPD Series Power Supply Limited W arranty What does this warranty cover and how long does it last? This Limited W arranty is provid ed by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your XPD 500 W att Series DC Power Supply .
Release A iii Direct returns may be performed accordi ng to the Xantrex Return Material Authorization Policy described in your pr oduct manu al. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities.
iv Operating Manual for XPD Series Power Supply Disclaimer Product THIS LIMITED W ARRANTY IS THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YO UR XANTREX PRODUCT AND IS, WHERE.
Release A v Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNL ESS SPECIFICALL Y AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO W ARRANTY AS TO THE ACCU RACY , SUFFICIENCY OR SUIT ABILITY OF ANY TECHNICAL OR O THER INFORMA TION PROVIDED IN MANUALS OR OT HER DOCUMENT A TION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT ; AND b.
vi Operating Manual for XPD Series Power Supply W arnings and Cautions W arnings and cautions are defined and fo rmatted in this manual as shown below . Power Supply Safety W ARNING Describes a potential hazard which could result in injury or death, or , a procedure which, if not performed correctly , could result in injury or death.
Release A vii About This Manual This Operat ing Manual conta ins operating information for the XPD Series of high-performance, switching , laboratory powe r supplies, available in several voltage models at 500 watts.
About This Manu al viii Operating Manual for XPD Series Power Supply Power Supply Safety Markings Alternating Current Off (Supply) Earth (Ground) T erminal On (Supply) Protective Conductor T erminal Caution (Check manual for additional information.
Release A ix Content s About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Features and Specifications Description . . . . . . . . . . . . . . . . . . . . . . . . . . .
x Operating Manual for XPD Series Power Supply Section 3. Local Operation Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Standard Operation . . . . . . . . . . . . . . . .
Release A 11 Section 1. Features and S pecifications Description The XPD Series of DC power supplies provides stable, variable output voltage and current for a broad ran ge of development and system requirem ents. The units use high-frequency soft-switching technology to achieve high power density and retain a small package size.
Section 1. Features and Specifications Front Panel Controls 12 Operating Manual for XPD Series Power Supply • This unit may be equipped wi th an optional internal GPIB or RS-232 con trol for remote digital programming and readback. • Remote output sensing provides load cable compensation up to 5 V/line (3 V/line for 7.
Section 1. Features and Specifications Rear Panel Connectors Release A 13 Rear Panel Connectors Figure 1.2 500 W att Power Supply Rear Panel (7.5 V and 18 V) Figure 1.
Section 1. Features and Specifications Rear Panel Connectors 14 Operating Manual for XPD Series Power Supply Output Connectors Low V oltage Models Equipped with po sitive and negative busbars. The busbars are offset to facilitate load cable connections.
Section 1. Features and Specifications Rear Panel Connectors Release A 15 Rear Panel J210 Connector The J210 Analog Interface connector is a 15-pin female DS UB connector lo cated on the rear panel. See Figure 1.6 . Use the J210 pro gramming, monitoring, and shutdown 15 pin DS UB connector for remote programming and monitorin g functions.
Section 1. Features and Specifications Rear Panel Connectors 16 Operating Manual for XPD Series Power Supply T able 1.2 Rear Panel J210 Connector Pins and Fun ctions Pin Reference Name Function J210-1 TTL S/D RTN Shutdown Signal Return ( − ) Return for shutdown signal 1 .
Section 1. Features and Specifications Rear Panel Connectors Release A 17 Making J210 Connections Wiri ng For most connectors and jumpers, use any suitable wire such as 16 to 24 A WG stranded wire. For lowest no ise performance, use shielded pair wiring of 16 to 24 A WG .
Section 1. Features and Specifications Electrical Specifications 18 Operating Manual for XPD Series Power Supply Electrical Specifications These specifications are warranted over a temperature range of 0 °C to 50 °C with local sense. Above 50 °C, derate ou tput linearly to zero at 70 °C.
Section 1. Features and Specifications Additional Specifications Release A 19 Additional Specifications Input Conditions 1. Front output curre nt limited to 30 A m aximum. 2. For input volta ge variation over the AC input volt age range, with constant rated load.
Section 1. Features and Specifications Additional Characteristics 20 Operating Manual for XPD Series Power Supply Additional Characteristics Remote Programming and Monitoring Over T emperature Protection (OTP) Unit latches off whe n T > rated maximum.
Section 1. Features and Specifications Environmental Specifications Release A 21 Environment al S pecifications Mechanical Specifications Operating T emperature Range 0 to 50 °C S torage T emperature.
Section 1. Features and Specifications Mechanical Specifications 22 Operating Manual for XPD Series Power Supply Mounting Optional 19 in. (483 mm) rack mount kit (mounts 4 units). Maximum Dimensions (single output) Free standing: Height: 5.55 in. (140 mm) Width: 4.
Release A 23 Section 2. Inst allation Introduction This section provides recomm endations and procedures for inspecting, installing, and testing the power supply . Basic Setup Procedure See Ta b l e 2 . 1 for a summary of the basic setup procedure and a view of the subsections in this section.
Section 2. Inst allation Inspection, Cleaning, an d Packaging 24 Operating Manual for XPD Series Power Supply Inspection, Cleaning, and Packaging Initial Inspection When you first receive your unit, perform a quick physical check.
Section 2. Inst allation Returning Power Supplies to the Manufactu rer Release A 25 Returning Power Suppli es to the Manufacturer Return Material Authorization Policy Before returning a product di rectly to Xantrex you must obtain a Return Mat erial Authorization (RMA) number and the correct factory “Ship T o” address.
Section 2. Inst allation Returning Power Supplies to the Manufacturer 26 Operating Manual for XPD Series Power Supply Packaging for Shipping or Storage Follow these instructions to prepare the unit for shipping or storage.
Section 2. Inst allation Location, Mounting, and V e ntilation Release A 27 Location, Mounting, and V entilation Y ou may use the 500 watt power supply in rack-mounted or i n benchtop applications. Rack Mounting The power supply is d esigned to fill 1/4 of a stan dard 19 in.
Section 2. Inst allation AC Input Power Connection 28 Operating Manual for XPD Series Power Supply AC Input Power Connection AC Input Connector The AC input connector is a standard IEC 15 A, 250 V male connector located on the power supply’ s rear panel.
Section 2. Inst allation Functional T ests Release A 29 Functional T ests These functional test pro cedures include power -on and front pan el function checks as well as voltage and current mode operation checks.
Section 2. Inst allation Load Connection 30 Operating Manual for XPD Series Power Supply Load Connection This section provides reco mmendations for load wires and covers single and multiple load configurations. Load Wiring Make load connections at the rear of the power supply at the positive ( + ) and negative ( − ) terminals.
Section 2. Inst allation Load Connection Release A 31 Figure 2.2 Maximum Load Wire Length for 1 V Lin e Drop Noise and Impedance Effect s T o minimi ze noise pickup or radiation, use shielded pair wiring of shortest possible le ngth for load wires. Connect the shield to the power supply chassis.
Section 2. Inst allation Load Connection 32 Operating Manual for XPD Series Power Supply Inductive Loads T o prevent damage to the power supply from inductive kickback, connect a diode across the output.
Section 2. Inst allation Remote Sensing Release A 33 Remote Sensing Remote sensing permits you to shift the regulation point of the power supply from the output terminals to the load or other distribution terminals. It compensates for voltage losses of up to a total of 5 V in the power leads supplying the load (3 V on 7.
Section 2. Inst allation Remote Sensing 34 Operating Manual for XPD Series Power Supply T o compe nsate for losses in power leads c onnected to the output , your power supply provides sense connections beside the output terminals.
Release A 35 Section 3. Local Operation Introduction Once you have installed the po wer supply , it is ready to op erate in local control mode (that is, operation at the unit’ s front panel). • See “Standard Operation” for a brief explana tion of Constant V oltag e and Constant Current Mo de operation.
Section 3. Local Operation Standard Operation 36 Operating Manual for XPD Series Power Supply Figure 3.1 Operating Modes Const ant V oltage Mode Operation The power supply will operate in constant voltage mode whenever the load current I L is less the current limit setting I SE T , or: I L < I SET (Note: I L = V SET / R L ).
Section 3. Local Operation Shipped Configuration (Local Control Mode) Release A 37 4. Disconnect the shorting lead from the ou tput terminals. The power supply will now automatically switch into current lim iting mode (current regulation) as soon as the preset current level is reached.
Section 3. Local Operation Using Over V oltage Protection (OVP) 38 Operating Manual for XPD Series Power Supply Using Over V olt age Protection (OVP) The OVP circuit protects the load in the event of a remote programming error , an incorrect voltag e control adjustment, or a power supply failure.
Section 3. Local Operation Using the Shutdown Function Release A 39 Using the Shut down Function Use the shutdown function to dis able or enab le the supply’ s output via a logic level signal so that you can make adjustments to either the load or the power supply without shutting of f the power supply .
Section 3. Local Operation Using Multiple Supplies 40 Operating Manual for XPD Series Power Supply Using Multiple Supplies Y ou can operate power supplies of the SAME MODEL with outputs in series or in parallel to obtain increased load voltage or increase d current.
Section 3. Local Operation Using Multiple Supplies Release A 41 Configuring Multiple Supplies for Seri es Operation (V oltage Mode Only) Connect power supplies in series to obtain a single output supply with higher output voltage. Connect the negative (–) terminal of one supply to the positive (+) terminal of the next supply .
Section 3. Local Operation Using Multiple Supplies 42 Operating Manual for XPD Series Power Supply Configuring Multiple Supplies for Parallel Operation Connect power supplies in parallel to obtain a single output supply with a higher output current limit.
Section 3. Local Operation Using Multiple Supplies Release A 43 Configuring Multiple Supplie s for Split Supply Operation Split supply operating uses two power suppli es to obtain two positive voltages with a common ground, or to obtain a positive-negative supply .
Section 3. Local Operation Using Multiple Supplies 44 Operating Manual for XPD Series Power Supply Positive-negative supply T o obtain a positive-nega tive supply , connect the negative output terminal of one supply to the positive terminal of the second supply .
Section 3. Local Operation User Diagnostics Release A 45 User Diagnostics If your power supply i s not performing as described in this manu al, run through th e procedures and checks in this section before calling your service technician. These procedures are confin ed to operator leve l functions only .
Section 3. Local Operation User Diagnostics 46 Operating Manual for XPD Series Power Supply T able 3.2 User Diagnostics Symptom Check Further Checks and Corrections No output and the display is blank. In input voltage within specified range? Connect to appropriate voltage source.
Section 3. Local Operation User Diagnostics Release A 47 Output voltage fluctuating or regulation poor . Is unit at current limit? Increase current limit setting or reduce load. See “Standard Operation” on page 35 . Is input voltage within specified range? Connect to appropriate AC voltage source.
Section 3. Local Operation User Diagnostics 48 Operating Manual for XPD Series Power Supply.
Release A 49 Section 4. Remote Operation Introduction The switches and connec tor on the rear panel of th e power supply allo w you to program the supply with an analog de vice or to readback analog signals.
Section 4. Remote Operation Readback and Status Indicators 50 Operating Manual for XPD Series Power Supply Remote Programming Options See Ta b l e 4 . 1 for a summary of the options available to you for programming outpu t voltage and current limit usin g an analog source.
Section 4. Remote Operation Status Flags Release A 51 St atus Flags The power supply has 5 status flags to in dicate the operating state. The S/D LED on the front panel, and 4 LEDs visible from the top of the unit. The flags, listed in order from front to rear , are OTP , OVP , SNS-PROT and AC-F AIL.
Section 4. Remote Operation Status Flags 52 Operating Manual for XPD Series Power Supply.
.
Xantrex Technology Inc. 8999 Nelson W ay Burnaby , British Columbia Canada V5A 4B5 604 422 8595 T el 604 421 3056 F ax 800 667 8422 T oll Free North America prg.
Een belangrijk punt na aankoop van elk apparaat Xantrex Technology XPD 120-4.5 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Xantrex Technology XPD 120-4.5 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Xantrex Technology XPD 120-4.5 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Xantrex Technology XPD 120-4.5 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Xantrex Technology XPD 120-4.5 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Xantrex Technology XPD 120-4.5 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Xantrex Technology XPD 120-4.5 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Xantrex Technology XPD 120-4.5 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.