Air intake capacity l/min.
Tank cap. litres
Sound pressure level dB(A)
36514 L 20/95 Silent
0,75/1,0 95 8 20 60 29 40x40x62


5. FIRST USE 1. After having removed the compressor from the packing, check that no parts have been damaged during transport. 2. The packing material has to be disposed of in compliance with the regulation in force in the country where the compressor is being erected or recycled or reused. 3. Install the compressor on a flat surface, in a suitably sized room, well ventilated and not wet, where the temperature is not likely to rise above 34 °C. If there is not enough air ventilation, install a suitably sized exhauster or fan. OIL MUST NEVER BE OVER THE MAX. OIL LEVEL. To guarantee an optimal performance it is suggested to use Airpress compressor oil (article no. 36398) with excellent resistance to alternate thermal conditions and oxidation. DO NOT MIX DIFFERENT TYPES OF OIL. Keep any oil remaining in the bottle for future topping up. Now insert the intake filter on the pipe (or in the hole) with the pressure of your hand. After having added the oil, never overturn or excessively tilt the compressor as this would cause the oil run out. The power supply voltage must be the same as indicated on the data label: 230 V/50 Hz and the socket must be 2 pole+ground type. Fig. 1 (see also page 32)


If all the above indications have been followed, you can start the compressor as follows: - turn the pressure switch knob to position “0” (see fig. 1 and 2). - insert the plug into the socket and start the compressor turning the pressure switch knob to position “1”. The compressors working process is automatic. The pressure switch stops the compressor when the pressure in the tank reaches the maximum value allowed and starts it again when the pressure drops to the minimum value. Adjust the outlet air pressure operating on the reducer-filter knob (see fig. 1 and 3): a) turning the knob clockwise the pressure will rise; b) turning the knob counter clockwise the pressure will decrease; If the pressure switch does not work (overpressure), the safety valve will automatically operate and open when the pressure exceeds the max. setted value. NEVER REMOVE OR REPAIR THIS VALVE. WARNING! The compressor must be connected to an outlet protected by a suitable magneto-thermal switch. The table below shows the absorption data of the compressor: Model 36514 230 V/50 Hz 3,5A 750 W


Avoid the use of extension cables. If you use them, unroll them completely and use cables of sufficient capacity. Use only cables with a diameter of at least 1,5 mm². ATTENTION: while working the motor/air hose unit, reaches high temperature. If working near this unit do not touch (risk of burning). Limits for continuous operation Curve no 1 indicates the length of

continuous running at varying pressures, until the overload protector switches off the motor (at approx. 115 °C oil temperature measured from 20 °C start point). Example: 6 bar = 116 minutes. Curve no 2 indicates the
recommendable proportion of operation and standstill. Example: at 4 bar max. operation is 76% of the time, corresponding to 46 minutes operation/ 14 minutes standstill per hour. The curves represent average values at 230 V/50 Hz operation, with an outside temperature = 20 °C.

disconnected. always use original spare parts. all maintenance jobs must be carried out by skilled personnel.
Once a week check the oil level shown by the glass. When the motor is off,

the oil level must correspond to the one shown by the label. Once a month drain the water collected in the air outlet filter (Fig. 4)
o turn the button clockwise; o pushing the button drain the condensate contained in the bowl: o at the end of this operation turn the button counter clockwise. Remove regularly the condensate that has collected in the air tank. To empty
the tank, put it under pressure and open the tap on the bottom of the tank (Fig. 5). For compressors with a pancake tank, open the drain plug placed on the upper part of the tank and eliminate the water using the apposite little tube. Remove the condensate according the regulations: never let it drain into the sewerage! Fig. 5 Fig. 6


o possible connectors slackening o pressure hose wear o screws tightening o electric circuit efficiency Every 3 months check the air intake filter. Replace if necessary. Every 6 months disassemble the coalescing cartridge contained in the air
outlet filter (Fig. 6). This operation must be done with the tank completely out of pression. 8. TROUBLESHOOTING WARNING! Before carrying out any operation on the compressor, disconnect the
plug from the socket. Empty all the air from the air tank before dismantling any part of
compressor unit’s pressure system. Following operations must be carried out by professionally skilled
personnel. 1. The compressor does not start: a) no power from mains. Check fuses and socket. b) breakage of loose joints in electrical connections. Check with tester for
continuity as per wiring diagram. c) due to a wrong filling up, the oil level is too high. On this condition, the motor
cannot start. It is so necessary to disassemble the oil sight glass, to let the exceeding oil come out from the hole, to assemble again in a correct way the oil sight glass and to restore the correct oil level. d) pressure in air tank too high for activation of pressure switch. The pressure
switch makes circuit only when pressure has dropped to preset start pressure. e) leaky non-return valve. Take off the flexible pressure pipe to see if air leaks
out from the valve. If so, unscrew the valve cap (Fig. 7 ref. 1), clean the rubber disk (Fig. 7 ref. 2) and his place with a dry cloth and assemble the whole with care. If the leakage persists, the whole valve must be replaced.

Fig. 7 2. The compressor works, but pressure does not increase in tank (or increases too slowly): a) the transportation cap has not been removed from the air intake pipe (or

hole). b) air filter is clogged: clean or replace. c) check for air leaks (see point 6). 3. The compressor does not reach the maximum pressure: a) check any air leak (see point 6). b) check the pressure switch efficiency and if necessary adjust it (Fig. 8).
Remove the cover. To adjust the maximum pressure operate on screws “A” and “B”. Turning clockwise the pressure rises, turning counter clockwise the pressure decreases. c) a failure in the non-return-valve is creating a flow restriction. Replace the
valve. 4. The compressor runs but does not load: a) the defect can be due to a valve or a gasket break (Fig. 9); replace the
damaged part immediately. 5. The compressor stops while working:

a) the motor has an automatic resetting thermal protection, that stops the
compressor when the temperature is too high. The compressor will start again automatically after 15/20 minutes. 6. Air leaks: a) can be due to bad seal of any connection, check all connections wetting with
suds. 7. Leak from the valve placed under the pressure switch: a) damaged valve, replace it. b) the defect can be due to an imperfect valve seal (see point 1. e). 8. The compressor starts when no air is being tapped: a) air leak (see point 6). 9. The compressor starts and stops more frequently than usual: a) large amount of condensate in air tank; remove condensate. b) air leak (see point 6). 10. The compressor does not switch on when pressure is under the minimum level and/or does not switch off at max. pressure: a) defective pressure switch, replace. 11. The compressor gets very hot and/or uses a lot of oil: a) oil level incorrect (see point 1. c). b) wrong oil has been filled in the compressor. Use oil recommended by the
manufacturer only. c) air leak (see point 6). d) clogged intake filter: clean or replace. e) too high outside temperature: do not close the unit in a cupboard unless
adequately ventilated. The compressor should be placed in the coolest possible place. f) over-running; ensure the compressor is the correct model for your work load. SCRAPPING THE UNIT If the machine is to be scrapped, it must be dismantled into parts of the same material, to be disposed of according to the local regulations in force. Always respect the regulations in force for disposing of old oil and other polluting materials such as rubber, plastic, etc. SPARES Defective parts must be replaced only by authorized personnel; all possible safety regulations must be observed in order to avoid any damage to people or things.

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.