Thank you for selecting our product. We hope that you will enjoy use of the appliance.
Symbols in these Instructions for Use Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid accidents and prevent damage to the machine:
Read the operating instructions carefully before putting the appliance into operation and keep the instructions including the warranty, the receipt and, if possible, the box with the internal packing. If you give this device to other people, please also pass on the operating instructions.

1 Suction hose 2 Air control 3 Telescopic suction tube 4 Connection head of the vacuum hose 5 Hose connection 6 Dust collector with HEPA filter 7 Carrying handle 8 Dust collector release button 9 Cable-winding button 10 On/off switch 11 Positioning aid 12 Lever for opening the ventilation grille (with output filter) 13 Dust collector base plate 14 Lever for extending and retracting the brushes 15 Floor nozzle (with hook (not shown))
Best use of the appliance depends on the texture of the floor covering. We recommend the following use:
Crevice and jointed nozzle For vacuuming upholstery, curtains and in corners and crevices etc.
To detach the nozzle attachments from the suction pipe, pull them off by turning them slightly.
Nozzle Attachment Floor nozzle (15)
The floor nozzle is fitted with rollers for easier guiding. You can clean smooth surfaces and carpets with the floor nozzle.
• · •

Filter Your appliance features 4 filters. The common dust bag system has been replaced by a transparent dust collector. The higher flow speed of the collector allows for heavy dirt and smallest floating particles to be separated from the “sucked-in air”.
It is thus not necessary to buy dust bags.
HEPA filter Clean the filter element twice a year.
Air Slide (2) Open the air slide on the hose handle in order to regulate the airflow or to clear any particles sticking to the nozzle.
Switching off and Winding up the Mains Lead 1. Turn the vacuum cleaner off by the on/off switch and remove the plug from the socket. 2. Keep the plug in your hand. 3. Press the cable winding button and guide the cable. Hold the cable to avoid wrapping.
Proceed as follows to remove, clean and reinstall the filter ele- ment:
marking on the lid towards the
symbol. Pull the filter element from the dust collector. 3. Remove the filter element from the lid by turning the filter element towards
Emptying the dust collector Empty the dust collector once the collected dirt reaches the MAX marking.
. 4. Pull the nylon filter from the HEPA. 5. Use a brush to clean the filters. In case of heavy staining, clean the filters under running water. 6. Let the filters air-dry completely before refitting them! 7. Wipe the dust collector with a damp cloth and then wipe it dry. 8. Once the filters are completely dry, attach the nylon filter to the HEPA filter (see the figure on page 3). 9. Reinsert the filter element into the lid of the dust collector, using the notches in the lid. Turn the filter element towards the

symbol until it clicks into place. 10. Reinsert the lid including the filter element into the dust collector. Close the lid until the

marking is aligned with the
symbol. 11. Fit the dust collector in the appliance.
Outlet filter The appliance is also equipped with an outlet filter. It is located on the rear of the device under the parking aid. 1. Push down the lever (12) and remove the ventilation grille. 2. Remove the filter insert and clean it as described above. 3. Place the completely dry filter back into the ventilation grille. 4. Put the ventilation grille back on the appliance. Observe the guide lugs. The ventilation grid must engage audibly.

Model: BS 1304 Power supply: 220-240 V~, 50/60 Hz Protection class: II Net weight: 4.50 kg
Clean the housing with a soft, dry cloth without additives.
The right to make technical and design modifications in the course of continuous product development remains reserved.
Technical Data for vacuum cleaners COMMISSION DELEGATED REGULATION (EU) Nr. 665/2013

Remedy: Check the connection to the mains. Check the position of the switch.
Possible Cause: The dust collector is full.
Remedy: Empty the dust collector.
Possible Cause: The filters are dirty.
Remedy: Clean the components.
Possible Cause: There is a foreign body in the suction tube or the nozzle.
Remedy: Check the accessories for foreign bodies.
or · or

Meaning of the “Dustbin” Symbol Protect our environment: do not dispose of electrical equipment in the domestic waste.
Please return any electrical equipment that you will no longer use to the collection points provided for their disposal.
This helps avoid the potential effects of incorrect disposal on the environment and human health.
This will contribute to the recycling and other forms of reutilisa- tion of electrical and electronic equipment.
Information concerning where the equipment can be disposed of can be obtained from your local authority.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.