On no account should the device be used to suck up the following:
– liquids or wet substances (e.g. wet carpet shampoo)
– glowing ash, cigarette ends, matches, etc.
– infl ammable or explosive substances
– very fi ne dust (e.g. concrete dust), ash or toner
people with reduced physical, sensory or mental abilities or a lack of experience and/or knowledge if they are supervised or have received instruction on how to use the device safely and have understood the dangers resulting from failure to comply with the relevant safety precautions.
children, unless they are older than 8 years of age and are supervised.
away from the device and the mains cable.
when it is left unattended and before assembling, disassembling or cleaning the device.
or other liquids and ensure that they cannot fall into water or become wet.
for damage each time before you use it. The device may only be used if it has no visible signs of damage! If the device, the mains cable or the mains plug of the device is damaged, it must be replaced by the manufacturer, customer service department

or a similarly qualifi ed person (e.g. specialist workshop) in order to avoid any hazards.



1 Suction hose handle 2 Telescopic tube 3 Dust container lid with handle 4 Dust container release button 5 Floor nozzle 6 Connection piece 7 Cyclone insert with 2 motor fi lters (sits inside the dust container) 8 Dust container 9 Suction hose
10 Auxiliary air vent 11
button for cable retraction 12 Mains cable with plug 13 Floor nozzle holder 14 Exhaust hatch (the HEPA exhaust air fi lter is located behind this hatch) 15 On / Off switch

The fl oor nozzle is suitable both for carpets and smooth fl oors. With the foot switch, you can switch between smooth fl oor and carpet. A brush is deployed on the bottom for smooth fl oors.

Tile / brush nozzle




Floor nozzle

1. If you have not already done so, attach the desired suction nozzle to the telescopic tube or suction hose (see chapter “Assembly”, section “Mounting / removing suction nozzles” and chapter “Product contents and device overview”, section “Suction nozzles”). 2. Pull the mains cable out of the housing, ideally as far as the yellow mark but in any case no further than the red mark on the cable! 3. Insert the mains plug in a properly installed socket that is easily accessible. 4. Press the On / Off switch to turn the vacuum cleaner on. 5. Move the nozzle over the surface you want to clean. You can pull the vacuum cleaner like a sled when vacuum cleaning.
Tipp: There is an auxiliary airfl ow vent on the handle. Open this (by sliding the cover) in order to reduce the suction power when vacuuming upholstery, carpets or lightweight, easily movable objects. The auxiliary airfl ow vent should normally be kept closed so that the suction power is not unnecessarily reduced. 6. After vacuum cleaning, press the On / Off switch again to turn off the device. 7. Remove the mains plug from the mains socket, hold on to the mains cable and press the cable retraction button

with your foot. By holding the mains cable, you prevent it from lashing against body parts such as your legs. 8. For optimum performance, empty the dust container after each use and clean the cyclone insert, motor fi lters and HEPA exhaust air fi lter regularly (see chapter “Cleaning and care”).

Over time the fi lters may become discoloured. This is normal and does not affect the functionality.


Cleaning the cyclone insert and motor fi lters The cyclone insert is situated inside the dust container. The motor fi lters are situated in the fi lter holder on the cyclone insert.


6. You can clean the cyclone insert and dust container with a damp cloth. 7. After drying, place the foam fi lter back into the fi lter holder and replace the holder onto the cyclone insert. Close the lid so that it audibly locks into place. Attention: Never put damp parts back into the dust container! 8. When all parts are dry, replace the cyclone insert in the dust container. 9. Put the lid on the dust container so that the arrow symbol on the dust container points to the symbol on the lid. Close the lid by turning it as far as it will go. The arrow symbol should now be pointing to the symbol. 10. Put the dust container in the device. Make sure that it audibly locks into place.
Cleaning the HEPA exhaust air fi lter The HEPA exhaust air fi lter is situated behind the protective grill on the back of the vacuum cleaner.



If the device should stop working properly, fi rst check whether you are able to correct the problem yourself.
Do not attempt to repair a defective electrical device yourself!
Problem Possible cause / solution
The vacuum cleaner has no suction power.
The suction performance is poor.
The device emits dust when vacuuming.
The mains cable will not completely retract.
again.
An unpleasant odour develops when vacuuming.
Article numbers: 08302 (gold) 08318 (red) 09897 (blue / silver) 04765 (pink / silver) 09096 (zebra design) Model number: C-320-70 / C-320-80 Voltage supply: 220 – 240 V ~ 50 / 60 Hz Power: 700 W Protection class: II
(Calls to German landlines are subject to charges. The cost varies depending on the service provider.)

The packaging material is recyclable. Please dispose of it in an environmentally friendly manner and take it to a recycling centre.
Dispose of the article at a recycling centre for used electrical and electronic devic- es. You can obtain more information from your local authorities.
All rights reserved.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| The vacuum cleaner has no suction power. | • Is the mains plug not correctly connected with a socket? Correct the position of the mains plug. • Is the socket defective? Try another socket. • Check the fuse for your mains connection. | p.10 | |
| The suction performance is poor. | • Is the suction power set too low on the suction power control? Turn the suction power control more towards MAX. • Is the auxiliary air vent on the handle open? Close it. • Is the dust container too full? Empty the container. • Are the fi lters heavily laden with dirt? Clean the cyclone insert, motor fi lters and HEPA exhaust air fi lter. • Is the nozzle, telescopic tube or suction hose clogged? Turn the device off, pull the mains plug out of the socket and remove the obstruction (also see chapter “Assembly”). | p.10 | |
| The device emits dust when vacuuming. | • Has the dust container not been closed properly and/or is it not (properly) inserted in the device? Correct this. • Are the fi lters heavily laden with dirt? Clean the cyclone insert, motor fi lters and HEPA exhaust air fi lter. | p.10 | |
| The mains cable will not completely retract. | • The mains cable has not been correctly retracted into the device. Pull it out a little and press the cable retraction button again. | p.10 | |
| An unpleasant odour develops when vacuuming. | • Are you using the device for the fi rst time? An odour often develops when using new devices for the fi rst time. The odour should disappear once you have used the device a few times. | p.10 |
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.