label attached at the vacuum cleaner. Before use, please check the vacuum cleaner, the power cable and plug for damage.
Do not use a damaged machine! Do not use extension cords with inadequate current carrying capacity. Do not use outdoors! Keep the machine away from the ovens, stoves, etc. Do not use vacuum cleaner EUROM Force to pick up:

11 Liquids Burning, smoking or hot objects, such as coal and hot ash, glowing cigarettes and
match, etc. to large objects sharp objects like nails, parts of glass etc. volatile liquid, combustible gas, acids, explosive garbage, etc. dangerous materials like asbestos etc. flammable or combustible liquids such as gasoline. Don’t use the cleaner in areas
where they may be present. Do not put any object into openings. Do not use with any opening blocked; keep free
of dust, lint, hair and anything that may reduce the airflow. This vacuum cleaner creates suction and contains revolving brushroll. Keep hair, loose
clothing, fingers, and all parts of body away from openings and moving parts. Use extra care when cleaning on stairs. Do not wrest, tramp or haul the hose. Do not use the hose if it is broken. Do not pull or carry the vacuum cleaner by its cord. Never close the door on the cord,
or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord and don’t walk over it. Keep the cord away from heated surfaces. Do not use without dust bag or filter in place. Turn off the equipment before unplugging. Always switch off and unplug the vacuum cleaner when you stop the work, leave the
room and before emptying the barrel or maintaining/cleaning the equipment. Do not unplug by pulling the cord. To unplug, grasp the plug, not the cord. Do not touch plug and/or cable with wet hands and don’t use the vacuumcleaner
without wearing shoes.. ENSURE you turn the unit off at very minimum every 15 minutes (for 1 minute) to let
the motor cool down – failure to do so may cause motor failure! DO NOT use this unit for more than 4 hours (including rest breaks) on any given day. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Use only as described in this manual. Use only manufacturers’ recommended
attachments. Store your cleaner indoors in a cool, dry area. If the vacuum cleaner, the power cord or the plug becomes damaged or dysfunctions,
do not use the vacuum cleaner anymore, but take it to an authorized service agent to be repaired. Never repair it by yourself, that lets expire the guarantee and the responsibility of supplier.



A. combi floorbrush B. dust brush C. crevice tool OPERATION

Connect the hose to the equipment
Push with a twisting force the curved suction pipe (4) over the connection on the hose. Push, if you wish, a suction pipe (2) on the curved suction tube.



13 Push, if you wish, with a twisting force the second straight suction pipe on the first.

Push the combi floorbrush (1) with a twisting force on the straight suction pipe (2). Insert the plug into the socket


Press the switch on/off to turn on or, after the work, to turn off. . You can adjust the airflow by pushing the sliding block up and down.



14 By turning the capacity-regulator (10A) you adjust the capacity of the motor and so the suction power. After use you can tidy up the attachments as you see on the picture. Place the accessories on the holders X.
It is not allowed to use the the vacuum cleaner without dust bag. If the dust bag is full or broken, replace it as soon as possible. Switch off the equipment and unplug it. Open both the locking blocks (11) en take the up housing from the vacuum cleaner.


Remove the dust bag (Y), clean the barrel if necessary and place a new dust bag. Force the opening (Z) till over the ridge of the exit of the flexible hose, so that the rubber locks up correct! At the end, place back the up housing and close the locking blocks.
MAINTENANCE Never use this machine when the suction power becomes weak. Make sure that the capacity regulator is in the right position and the sliding block is
closed. Check or the dus bag is full; change it if necessary. Check the filter. If this is dirty, clean it. Check at last or the floorbrush, the suction pipe or the flexible hose are blocked by
any object. Remove it if necessary. However, don’t use the vacuum cleaner before the problem is solved!

15 When the filters are obviously covered with dust or the suction decreases considerably, please clean the filters. Do that in time, for this can improve the working efficiency and extend the life time of the vacuum cleaner. Never use the machine without filters.

- Take the dustfilter (1) out of the up
housing by removing the inside cover. - Take the HEPA-filter (2) uit of the machine
by twisting the locking knob anticlockwise.
Clean the filters carefully with clean water Let them dry by airing. When they are totally dry, replace and secure them in the same position as before.



CE - STATEMENT Euromac bv., Genemuiden-NL hereby declares that the EUROM FORCE vacuum cleaner complies with the LVD guideline 2006/95/EC and the EMC guideline 2004/108/EEC and meets the following standards: EN 62233:2008 EN 60335-2-2:2010 EN 60335-2-2:2003/A11:2010 EN 60335-1:2002+A11,A1:04+A12,A2:06+A13:08+A14:10+A15:11
EN 55014-1 :2006/+A1 :2009/+A2 :2011 EN 55014-2 :1997/+A1 :2001/+A2 :2008 EN 61000-3-2 :2006/+A1 :2009/+A2 :2009 EN 61000-3-3 :2008 Genemuiden, 06-05-2013 W.J. Bakker, alg. dir.


EUROMAC BV., Kokosstraat 20, 8281 JC Genemuiden
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.