NL
Metz logo
Officiële handleiding

Metz Mecablitz 26 AF-2

164 pagina's·519 KB·Flitsers·PDF·ENJA
Metz Mecablitz 26 AF-2
Inhoudsopgave 1 secties 12 Technical data Max. guide numbers at ISO 100: TonenVerbergen
Page 1 of the Metz Mecablitz 26 AF-2 user manual
Pagina 1 · klik om te vergroten
Pagina 1
  • Introduction Thank you for choosing a Metz mecatech product. We are delighted to welcome you as a customer. You will of course be impatient to start using the flash unit. However, it is worthwhile reading the operating instructions and learning how to use the unit correctly. The 26AF-2 flash unit comes in different versions and is accordingly suitable for:
  • Digital Canon cameras with E-TTL and E-TTL-II - flash metering.
  • Digital Nikon cameras with i-TTL flash metering.
  • Olympus/Panasonic - Digital cameras with TTL flash control and flash socket system, as well as the compatible digital cameras from Leica.
  • Digital Pentax cameras with P TTL flash metering .
  • Digital Sony reflex cameras with TTL preflash and ADI metering.
  • Digital FUJIFILM system cameras with TTL flash control.

Take a look at the diagrams at the end of the manual.

Proper Use This flash unit is intended solely for taking pictures of motifs in the photographic field. It may be operated only with the accessories described in this instruction manual or the accessories approved by Metz. The flash unit may not be used for any purpose other than that described above.

This flash unit is not suited for other brands of cameras.

Page 2 of the Metz Mecablitz 26 AF-2 user manual
Pagina 2 · klik om te vergroten
Pagina 2

Locking button ON / OFF button Battery compartment LED video light button

Slave sensor Telephoto lens cover Wide angle diffuser disk (recessed)

*dependant on camera model

Press once1/1 performance
Press twice1/2 performance

LED flashes slowly Video light off due to switch to another operating mode. SLAVE button TTL button STATUS LED

Flash-ready indication (green) Exposure control indication (red) USB socket (micro) LED video light/AF auxiliary light

Video light if: Switch video light on by pressing the button or data bus of the camera* for video (dependent on camera model)

LED stays on

Page 3 of the Metz Mecablitz 26 AF-2 user manual
Pagina 3 · klik om te vergroten
Pagina 3

1 Safety instructions The flash unit may in no event be activated in the vicinity of inflammable gases or liquids (petroleum, solvents etc.). RISK OF EXPLOSIONS! Do not flash directly into eyes from a close distance! Direct flashing into the eyes of persons or animals can cause damage to the retina and severe disruption of the vision – up to and including per- manent blindness! Never use a flash unit to photograph car, bus, bicycle, motorbike or train drivers while they are driving. Blinding the driver can lead to an accident! If the housing has been damaged in such a way that internal components are exposed, the flash unit may no longer be used. Remove the batteries! Do not touch any internal components. HIGH VOLTAGE! After repeated flashing, do not touch the diffuser. Risk of burns! Do not dismantle the flash unit! HIGH VOLTAGE! Repairs should only be performed by authorised service personnel.

  • Only use the power sources designated and authorised in the operating manual!
  • Do not open the batteries or short them!
  • In no event the batteries be exposed to high temperatures like direct sunlight, fire or similar!
  • Never throw flat/dead batteries onto a fire!
  • Do not use any toxic batteries or rechargeable batteries!
  • Remove the used batteries immediately from the device! Chemicals can escape from used batteries (so-called “leaks”) resulting in damage to the device!
  • Batteries may not be recharged!
  • Do not expose the flash unit to water drops and splashes!
  • Protect your flash unit from heat and high air humidity! Do not keep it in the glove compartment of your car!
  • Rapid changes in temperature may lead to condensation. If this occurs, allow time for the unit to become acclimatized!
  • When you activate the flash, there should be no opaque material directly in front of or on the reflector cover (flash window). The intense energy emissions can otherwise lead to scorching or spotting of the material and/or the reflector cover.
Page 4 of the Metz Mecablitz 26 AF-2 user manual
Pagina 4 · klik om te vergroten
Pagina 4
  • After a series of flashes with full power and short intervals, a pause of at least 3 minutes must be observed after each series of 20 flashes!
  • When taking a series of flash shots at full light output and with rapid recycling times due to the high level of thermal energy.

2 Dedicated flash functions Dedicated flash functions are flash functions that have been specially adapted to a given camera system. Depending on the type of camera, different flash functions are supported.

  • 26AF-2 Canon
  • Flash-ready indication in camera viewfinder/ camera display
  • Automatic flash sync speed control
  • E-TTL flash mode / E-TTL II flash mode
  • Automatic fill-in flash control
  • Manual flash exposure correction for E-TTL / E-TTL II (set on the camera if possible)
  • Flash exposure storage FE with E-TTL / E-TTL II
  • 1st or 2nd curtain synchronisation (REAR) (must be supported by the camera)
  • AF auxiliary light control (set on the camera if possible)
  • Programmed auto flash mode
  • Wireless remote slave E-TTL/M flash mode (set on the camera if possible)
  • Wake-up function for the flash unit
Page 5 of the Metz Mecablitz 26 AF-2 user manual
Pagina 5 · klik om te vergroten
Pagina 5
  • 26AF-2 Nikon
  • Flash-ready indication in camera viewfinder/ camera display.
  • Correct exposure indicator in camera viewfinder /camera display.
  • Automatic flash sync speed control.
  • i TTL flash mode / i TTL BL flash mode
  • Manual flash i TTL exposure correction (set on the camera if possible)
  • Flash exposure measurement memory for i TTL and i TTL BL 1)
  • 26AF-2 FUJIFILM
  • Flash-ready indication in camera viewfinder/ camera display.
  • Automatic flash sync speed control.
  • TTL with measuring preflash
  • Automatic flash / triggering control
  • Manual flash TTL exposure correction (set on the camera if possible)
  • 1st or 2nd curtain synchronisation (REAR) (set on the camera if possible)
  • AF auxiliary light control (dependant on camera model)
  • Programmed auto flash mode.
  • Preflash function for reducing the red-eye effect (set on the camera if possible)
  • Wake-up function for the flash unit.
  • /1st or 2nd curtain synchronisation (REAR) (set on the camera if possible)
  • AF auxiliary light control (dependant on camera model)
  • Programmed auto flash mode.
  • Wireless remote slave TTL/M flash mode (set on the camera if possible)
  • Preflash function for reducing the red-eye effect (set on the camera if possible)
  • Triggering control/auto-flash
  • Wake-up function for the flash unit.
1. not with Coolpix cameras
Page 6 of the Metz Mecablitz 26 AF-2 user manual
Pagina 6 · klik om te vergroten
Pagina 6
  • 26AF-2 Olympus
  • Flash-ready indication in camera viewfinder/ camera display.
  • Automatic flash sync speed control
  • TTL flash mode (with measurement pre-flash)
  • Micro-FourThirds/FourThirds-System compatible
  • Automatic fill-in flash control
  • Manual flash exposure correction for TTL (set on the camera if possible)
  • Automatic flash / triggering control
  • 1st or 2nd curtain synchronisation (2nd Curtain / SLOW2) (set on the camera if possible)
  • AF auxiliary light control (set on the camera if possible)
  • Programmed auto flash mode
  • Wireless remote slave TTL/M flash mode (set on the camera if possible)
  • Preflash for red-eye reduction
  • Wake-up function for the flash unit
  • 26AF-2 Pentax
  • Flash-ready indication in camera viewfinder/ camera display
  • Automatic fill-in flash control
  • P-TTL flash mode
  • Automatic P-TTL-fill-in flash control
  • Manual flash exposure correction (set on the camera if possible)
  • AF auxiliary light control (set on the camera if possible)
  • Programmed auto flash mode
  • Wireless remote slave P-TTL flash mode (set on the camera if possible)
  • Preflash for red-eye reduction
  • Automatic flash / triggering control
  • Wake-up function for the flash unit
Page 7 of the Metz Mecablitz 26 AF-2 user manual
Pagina 7 · klik om te vergroten
Pagina 7
  • 26AF-2 Sony
  • Flash-ready indication in camera viewfinder/ camera display
  • Automatic fill-in flash control
  • Preflash TTL and ADI metering
  • Automatic fill-in flash control
  • Manual flash exposure correction
  • /1st or 2nd curtain synchronisation (REAR) (set on the camera if possible)
  • AF auxiliary light control (set on the camera if possible)
  • Wireless remote slave TTL/M flash mode (set on the camera if possible)
  • Programmed auto flash mode
  • Wake-up function for the flash unit

It is impossible to describe all camera types and their individual dedicated flash functions within the scope of these instructions. Therefore, please refer to the flash mode description in your camera’s operating instruc- tions to find out which functions are supported and which ones have to be set manually on the camera. Using lenses not equipped with a CPU (i.e., lenses without auto focus mode), results in certain functional limitations! 3 Preparing the flash unit for use 3.1 Mounting the flash unit Mounting the flash unit on the camera

  • Turn off the camera and flash before mounting or removing.
  • Press and Locking button (Remove the protective cap on Sony) and slide the flash unit, together with the connection base, into the camera’s hot shoe as far as possible.
  • Release Locking button – the flash unit is now locked. In camera housings which have no locking hole, the spring-loaded locking pin retracts into the housing of the flash unit to avoid damage to the surface.
Page 8 of the Metz Mecablitz 26 AF-2 user manual
Pagina 8 · klik om te vergroten
Pagina 8

Removing the flash unit from the camera

The disposable / rechargeable batteries are empty or dead if the recycling time (time from triggering a full-power flash, e.g. for TTL through a test flash, to the moment the flash-ready indicator lights up again) exceeds 60 sec. In VIDEO mode, the video light is switched off and the Video button LED flashes quickly.

Turn off the camera and flash before mounting or dismounting. • Press and Locking button and remove the flash unit with the connection base from the camera.

3.2 Power supply Suitable batteries/rechargeable batteries The flash unit can be operated with any of the following batteries:

  • Switch off the flash unit by pressing ON/OFF button until all LED displays turn off.
  • Remove the flash unit from the camera and slide the battery compartment cover outwards.
  • 2 nickel-metal-hydride batteries 1.2V, type IEC HR3 (size AAA).
  • 2 alkaline-manganese dry cell batteries 1.5V, type IEC LR3 (size AAA).
  • 2 lithium batteries 1.5V, type IEC FR3 (size AAA).
  • Insert batteries according to the picture.
  • Depress the inserted batteries with the battery compartment cover and push the battery compartment cover back inside. When inserting batteries, ensure that the polarity is correct and matches the symbols in the battery compartment. Inserting the batteries in the wrong direction can destroy the flash unit! Always replace all batteries simultaneously, and make sure that batteries are the same brand and have the same capacity.

Please only use the power sources given above. If other power sources are used, there is a risk of damaging the flash unit. If your flash unit is not going to be used for an extended period of time, remove the batteries. Replacing batteries

Page 9 of the Metz Mecablitz 26 AF-2 user manual
Pagina 9 · klik om te vergroten
Pagina 9

Flat or dead batteries should not be disposed of with ordinary household waste. Help protect the environ- ment, and dispose of flat/dead batteries at the appro- priate collection points.

. . . switched to stand-by mode, (Auto-OFF) to save energy and to protect the power source from unintentional discharging. The flash-ready indicator goes out. The STATUS LED flashes red in stand-by mode. The most recently used operating setting is retained after automatic shutdown and is immediately restored when the camera is switched on. The flash unit can be turned on again by tapping the shutter release (wake-up function). The flash unit shuts off completely approx. 1 hour after last use (AUTO-OFF).

  • 3.3 Switching the flash unit on and off
  • Press ON/OFF button . The flash unit switches on afterwards with the mode of operation that was used last..
  • To switch it off, press ON/OFF button until all LED displays turn off.

To check the function, press the TTL-button for (approx. 3sec.). A testflash will be released.

If the flash unit will not be used for an extended period of time, we recommend that you switch off the flash unit with the ON/OFF button and remove the power source (disposable/rechargeable batteries).

In slave and Videolicht the automatic cut-off is not activated. The flash unit should always be turned off using the ON/OFF button if it is not going to be used for an extended period.

  • 3.4 Standby / Auto OFF for the flash unit The flash unit is configured so that 10 minutes after -
  • being switched on,
  • a flash is fired
  • the shutter release is actuated
  • the camera’s exposure metering system is switched off. . .
Page 10 of the Metz Mecablitz 26 AF-2 user manual
Pagina 10 · klik om te vergroten
Pagina 10

4 LED displays on the flash unit 4.1 Flash readiness indication When the flash capacitor on the flash unit is charged, the STATUS-LED button lights up in green, thus indicating that the flash unit is ready. This means that flash light can be used for the next shot. Flash readiness is also transmitted to the camera and indicated accordingly in the camera's viewfinder. If a photograph is taken before flash readiness appears, then the flash unit will not be triggered. If the camera has already switched to flash sync speed, the shot may have the wrong exposure.

- reduce the distance to the subject or to the reflection

surface (e.g. for indirect flashes), or - set a higher ISO value on the camera.

4.2 Correct exposure indication If the exposure is correct, then button STATUS-LED lights up in red for around 3 seconds if the photograph has been correctly exposed in flash modes TTL; (see 5.1)! If there is no exposure control indication after the shot in the TTL mode of operation, then the photograph was underexposed. In that case, you must: - set the next smaller f-stop (e.g. use f-stop 8 instead

of 11), or

Page 11 of the Metz Mecablitz 26 AF-2 user manual
Pagina 11 · klik om te vergroten
Pagina 11

5 Flash modes Depending on the camera or flash unit type, various TTL flash modes and the SLAVE flash mode are available. The video light can be switched on for videos. The flash mode is set by using the assigned TTL, SLAVE or LED button.

  • Setting procedure
  • Switch on the flash unit with the ON/OFF button .
  • Press the TTL button on the flash unit to set the TTL mode of operation .
  • Set a suitable mode of operation on the camera, e.g. P, S, A .
  • Tap the shutter release to transfer data between the flash unit and the camera.

5.1 TTL operating modes The TTL flash modes offer a simple method of obtaining very good flash shots. In TTL flash mode, the exposure is measured by a sensor in the camera. It measures the light reflected by the subject through the lens (TTL = "Through The Lens"). Here the camera automati- cally determines the flash performance required for a correct exposure of the shot. The advantage of the TTL flash mode is that all factors influencing exposure (e.g. filters, change of aperture and focal length changes with zoom lens, extensions for close-ups, etc.) are automatically taken into account in adjusting the flash light. If the shot is exposed correctly, the STATUS LED lights up in red for approx. 3 seconds (see 4.2).

5.1.1 E TTL- and E TTL II - flash mode (Canon) E-TTL and E-TTL-II flash modes are digital flash modes.

5.1.2 i-TTL/i-TTL-BL flash mode (Nikon) The i-TTL flash mode is supported by CLS-compatible Nikon cameras. The i-TTL-BL flash mode are only supported by CLS-compatible cameras if lenses are used that transmit distance data to the camera (for example, "D-AF Nikkor lens"). When shooting this data is taken into consideration in addition in adjusting the flash exposure.

Some cameras do not support the BL function in combination with SPOT exposure metering! In these cases, the normal i-TTL flash mode is set.

To define the range of the flash unit, see table (page 160).

Page 12 of the Metz Mecablitz 26 AF-2 user manual
Pagina 12 · klik om te vergroten
Pagina 12

5.1.3 TTL flash mode with measurement pre-flash (Olympus) The TTL flash mode with measuring preflash is a further development of the standard TTL flash mode of analo- gue cameras.

5.1.6 TTL flash mode with measurement pre-flash (FUJIFILM) The TTL flash mode with measuring preflash is a further development of the standard TTL flash mode of analo- gue cameras.

Depending on the camera model, the preflashes precede the main flash by such a short interval that they practically cannot be distinguished from the main flash! The preflashes do not contribute to the lighting of the shot.

5.2 Automatic Fill-in flash mode The automatic fill-in flash mode is activated by most cameras when the automatic programme P is selected and by Vari or subject programmes during daylight (see camera operating manual). Fill-in flash mode overcomes troublesome shadows and produces a more balanced exposure between subject and background with contre-jour shots. The camera’s computer-controlled metering system sets the most suitable combination of shutter speed, aperture and flash output.

5.1.4 P-TTL flash mode (Pentax) The P-TTL flash mode is a digital TTL flash mode that is a further development of the TTL flash mode of analogue cameras.

5.1.5 Preflash TTL and ADI metering (Sony) Preflash TTL and ADI metering are digital TTL flash operating modes and refined versions of the TTL flash operation found in analogue cameras. In the case of ADI metering, additional distance data from the lens is incorporated into the flash exposure process. The selection and/or setting of the preflash TTL and ADI metering operating modes are carried out on the camera (see camera operating instructions).

Ensure that the contre-jour light source does not shine directly into the lens, as this will interfere with the camera’s TTL metering system! There is no setting or display for automatic fill-in flash in the flash unit.

Page 13 of the Metz Mecablitz 26 AF-2 user manual
Pagina 13 · klik om te vergroten
Pagina 13

5.3 Manual flash exposure correction in TTL flash mode This function must be set on the camera, see the camera user manual. The auto flash exposure mode of most cameras is adjusted to a reflection factor of 25% (the average reflection factor of flash subjects). A dark background that absorbs much of the light or a highly reflective bright background (backlit shots, for example) may result in, respectively, underexposure or overexposure of the subject. To offset these effects, the flash exposure can be adjusted manually for the shot with a correction value. The extent of the correction depends on the contrast between the subject and background!

in the display can change and be adjusted to the correction factor (depending on the camera model)! After the shot, remember to cancel the TTL flash exposure correction in the camera!

Strongly reflecting objects in the motif can have a negative impact on the camera’s automatic exposure. The photograph will be underexposed. Remove reflecting objects or set a positive correction value.

5.4 Remote slave flash mode Applicable to all versions: The slave flash units must be able to receive the light from the master or controller flash unit with the integrated slave sensors for the remote mode. Set the group and the remote channel on the camera, the master or the controller flash unit.

5.4.1 26AF-2 Canon The flash unit supports Canon`s wireless E TTL Remote System in slave flash mode (set on the camera if possible). Wireless remote control of one or more slave flash units by one master or controller flash unit on the camera (for example, mecablitz 64AF-1 digital Canon) or by the camera master (depending on the camera type) is thus possible

Exposure correction by means of alteration of the lens aperture setting is impossible, since the camera’s automatic exposure program regards the altered aper- ture setting as the normal working aperture setting. When setting the correction factor, the distance shown

Page 14 of the Metz Mecablitz 26 AF-2 user manual
Pagina 14 · klik om te vergroten
Pagina 14

For slave flash unit 26AF-2 , slave group A as well as all remote channels 1, 2, 3 and 4 are always set.

5.4.4 26AF-2 Pentax The flash unit supports the wireless Pentax PTTL remote system in slave flash mode (set on the camera if possible). Here wireless remote control of one or more slave flash units by a master or controller flash unit on the camera (for example, 64AF-1 digital Pentax) or by the camera’s master is possible. For slave flash unit 26AF-2 , all remote channels 1, 2, 3 and 4 are always set.

5.4.2 26AF-2 Nikon The flash unit supports the wireless Nikon remote system in slave flash mode (set on the camera if possible) and is compatible with the Nikon “Advanced Wireless Lighting” system. Here wireless remote control of one or more slave flash units by a master flash unit (depending on the camera type) on the camera (e.g. mecablitz 64AF-1 digital Nikon) or by the camera’s master is possible. For slave flash unit 26AF-2 , slave group A as well as all remote channels 1, 2, 3 and 4 are always set.

5.4.5 26AF-2 Sony The flash unit supports the wireless Sony remote system (CTRL and CTRL ) in slave flash mode (set on the camera if possible). Wireless remote control of one or more slave flash units by one master or controller flash unit on the camera (for example, mecablitz 64AF-1 digital Sony) or by the camera master (depending on the camera type) is thus possible. For slave flash unit 26AF-2 , slave group RMT as well as all remote channels 1, 2, 3 and 4 are always set.

5.4.3 26AF-2 Olympus As a slave flash unit (set on the camera if possible), the flash unit is compatible with the wireless Olympus RC flash system (RC = remote control). Here wireless remote control of one or more slave flash units by a master flash unit (depending on the camera type) on the camera (e.g. mecablitz 64AF-1 digital Olympus) or by the camera’s master is possible. For slave flash unit 26AF-2 , slave group A as well as all remote channels 1, 2, 3 and 4 are always set.

+

Page 15 of the Metz Mecablitz 26 AF-2 user manual
Pagina 15 · klik om te vergroten
Pagina 15

5.4.6 26AF-2 FUJIFILM The remote slave flash mode is not supported by FUJIFILM cameras at the time of printing this user guide. The 26AF-2 automatically switches to the TTL mode of operation after around 1-2 seconds after pressing the SLAVE button . When remote slave mode is supported by FUJIFILM cameras, the 26AF-2 can be used as a slave flash unit after a software update. Afterwards, wireless remote control of one or more slave flash units by a master flash unit (depending on the camera type) on the camera or by the camera’s master is possible. For slave flash unit 26AF-2 , slave group A as well as all remote channels 1, 2, 3 and 4 are always set.

  • Testing remote flash mode
  • Place the slave flash units in the desired positions for the shot. Use flash unit mounting foot to set up the slave flash unit. Assembly / disassembly of the stand
  • Press and Locking button and slide the flash unit, together with the connection base, into the mounting foot as far as possible.
  • Press and Locking button and remove the flash unit with the connection base from the mounting foot.
  • Wait for the flash readiness of all connected flash units. Once the slave flash units have achieved flash readiness, the STATUS LED lights up in green.
  • Press the manual firing button on the master or controller flash unit to fire a test flash. The slave flash units respond with a test flash, if supported by the camera. If a slave flash unit does not issue a test flash, correct the position of the slave flash unit to enable the slave sensor to receive the light sent by the master/controller flash unit.
  • Depending on the camera model, the camera’s internal flash unit can also function as a master or controller flash unit. Please consult the respective camera operating instructions for further tips on setting the master or controller flash unit. Remote slave flash mode settings
  • Switch on the flash unit with the ON/OFF button .
  • Press the SLAVE button on the flash unit to set the Remote-Slave mode of operation. The setting is immediately effective and automatically saved.
Page 16 of the Metz Mecablitz 26 AF-2 user manual
Pagina 16 · klik om te vergroten
Pagina 16
  • 5.5 Video light Use the video light to illuminate shots of moving images at close range.
  • Press ON/OFF button . The flash unit switches on afterwards with the mode of operation that was used last.
  • Press the LED button on the flash unit to switch on the video light. Each time you press the “LED” button , the light output switches between “full” and “half” If the LED button lights up continuously, you have set the full light output; if it blinks slowly, the light output is set to half . If the batteries are almost empty, the video light switches off and the LED button blinks quickly.

6 Flash techniques 6.1 Bounce flash Bounce flash illuminates the subject more softly and reduces dense shadows. It also reduces the drop in light from foreground to background that occurs for physical reasons. The flash unit can be tilted vertically for indirect flash. To avoid colour cast in your shots, the reflective surface should be colour-neutral or white. The flash unit can be tilted via a hinge in the mounting foot. There are 4 different stop positions: - 0° / “lying" on the camera

First close-up range position, also for transport - 20°

Second close-up range position - 40°

Normal position (unit flashes in the direction of the optical axis) - 90° / main body is vertical

Position for indirect flashes (diagonally upwards)

Page 17 of the Metz Mecablitz 26 AF-2 user manual
Pagina 17 · klik om te vergroten
Pagina 17
  • Please note:
  • The two close-up range positions result in illuminated areas at different distances. In the 0° position, a test photograph, for example, should be taken to check whether there is any shadowing caused by the lens.
  • Indirect flashes with the 90° position illuminate the subject more softly and reduce dense shadows. This also reduces the light loss from the foreground to background that occurs for physical reasons.
  • When tilting the main flash body, make sure that it snaps into place in the 90° position to prevent direct light from falling on the subject from the reflector.
  • To avoid colour casts in your shots, the reflective surface should be colour-neutral or white.

6.2 Using the integrated wide-angle diffuser / telephoto lens cover The wide-angle diffuser and the telephoto lens cover change the beam angle of the flash unit. The wide-angle diffuser enlarges it so that shots with focal lengths up to 24mm1) are also illuminated uniformly. This requires a reduction of the guide number and hen- ce the range as well. By contrast, the telephoto lens cover bundles the light cone for focal lengths of 85mm1) and more, increases the guide number and hence increases the range.

1. Focal length information based on 35 mm format

Wide-angle diffuser When not in use, the integrated wide-angle diffuser is pushed into the body of the flash unit below the reflector cover.

  • Pull the diffuser vertically out of the flash body and allow it to fold onto the reflector cover of the flash unit. The diffuser is held in position by spring force.
  • To remove it, proceed in the reverse order.
Page 18 of the Metz Mecablitz 26 AF-2 user manual
Pagina 18 · klik om te vergroten
Pagina 18
  • Telephoto lens cover
  • Place on the reflector cover of the flash unit so that the lens cover snaps into place.
  • Pull to remove.

The camera uses the reflected light of the test flash to determine the light output required for the subsequent exposure. The actual main subject can then be brought into focus with the camera’s AF sensor/metering window. When the shutter release is pressed, the picture will be exposed with the previously defined light output of the flash unit!

6.3 Flash exposure memory FE Several Nikon, Sony and Canon cameras have a flash exposure memory (FV memory). This is supported by the flash unit in the Nikon i-TTL and i-TTL-BL and in the Canon E-TTL flash modes. It can be used to define and store the exposure level for the subsequent shot before the shot is actually taken. This can be useful when, for example, the flash exposure has to be adjusted to specific details that may not be necessarily be identical with the main subject. This function is activated on the camera. The subject details for the flash exposure are measured and brought into focus by the cameraís AF sensor/metering window. Pressing the camera’s AE-L/AF-L button (Nikon) or FE button (Canon; the description may vary from camera to camera; see the camera operating manual) causes the flash unit to fire a test flash. The stored metering value, for example “EL” or “FEL”, is then displayed in the camera viewfinder.

In Canon cameras, the flash exposure memory FE is not supported during the green fully-automatic programme, the Vari programme and the subject programmes! Further details regarding settings and handling can be found in the camera operating manual!

Page 19 of the Metz Mecablitz 26 AF-2 user manual
Pagina 19 · klik om te vergroten
Pagina 19

7 Automatic flash sync speed control Depending on the camera model and camera mode, the shutter speed is switched to flash sync speed when flash readiness is reached (see the camera’s operating instructions). Shutter speeds cannot be set faster than the flash sync speed, or they are switched automatically to the flash sync speed. Various cameras have a sync speed range, for example from 1/60 sec to 1/250 sec (see the camera’s operating instructions). The sync speed set by the camera depends on the camera mode, the ambient light, and the focal length of the lens used. Shutter speeds slower than the flash sync speed can be set according to the camera mode and the selected flash synchronisation.

8 Automatic AF auxiliary light With system cameras, the AF auxiliary light is possible only if the camera supports it. The automatic AF auxiliary light is activated in the flash unit by the camera when the ambient lighting conditions become inadequate for automatic focusing. The white video LED is activated and the subject on which the camera can focus is illuminated. The range is approx. 6- 9 m (with a standard 1.7/50 mm lens). Parallax error between lens and the AF auxiliary light limits the close-up range with the AF auxiliary light to approx. 0.7 m to 1 m.

If the AF auxiliary light is to be activated by the camera, the “Single AF (S)” or “ONE SHOT” autofocus mode of operation must be set on the camera and the flash unit must indicate flash readiness. Some camera models support only the camera’s internal AF measuring beam. In this case, the automatic AF auxiliary light of the flash unit is not activated (as in the case of compact cameras; see the camera’s operating instructions)! Low-speed zoom lenses can significantly curtail the range of the AF auxiliary light !

In cameras with a between-the-lens shutter, the flash sync speed is not controlled automatically. As a result, the flash can be used at all shutter speeds.

Page 20 of the Metz Mecablitz 26 AF-2 user manual
Pagina 20 · klik om te vergroten
Pagina 20

Some cameras support the AF auxiliary light in the flash unit only with the camera’s central AF sensor.

9 Triggering control (auto-flash) On some cameras, the flash will not be fired when the prevailing light is sufficient for an exposure. When the camera shutter release is depressed, no flash exposure is triggered. In various cameras, the triggering control only works in the full program mode or “P” program or must be activated on the camera (see camera operating instructions).

Page 21 of the Metz Mecablitz 26 AF-2 user manual
Pagina 21 · klik om te vergroten
Pagina 21

10 Care and maintenance Remove any dirt and dust with a soft, dry cloth. Do not use any cleaning agents – plastic components could be damaged.

10.2 Conditioning the flash capacitor The flash capacitor built into the flash unit undergoes a physical change when the device has not been used for a long time. For this reason it is necessary to switch the device every three months for approx. 10 mins. The power supplies must deliver enough power so that flash standby lights up no later than 1 min after switching on.

10.1 Firmware updates The firmware for the flash unit can be updated via the USB socket and can conform to the functions of future cameras (firmware update).

Checking the firmware version • Switch off the flash unit; to do this, press ON/OFF but- ton until all LED displays turn off.

  • Switch on the flash unit while holding down the TTL button , then release the button. The TTL button on the flash unit blinks, followed by the SLAVE button . The number of blink pulses indicates the firmware version; for example, if the TTL button blinks once and the SLAVE button blinks 3 times, firmware version 1.3 is installed.

For more information, visit the Metz homepage at www.metz-mecatech.de

Page 22 of the Metz Mecablitz 26 AF-2 user manual
Pagina 22 · klik om te vergroten
Pagina 22

11 Troubleshooting Should it happen that the flash does not work as specified, switch off the flash unit for about 10 seconds using the ON/OFF button . Check the camera settings and make sure the foot of the flash unit is mounted cor- rectly in the camera’s accessory shoe. Replace the batteries with new or freshly charged batteries. The flash unit should function normally again once it is switched back on. If this is not the case, contact your local dealer. Below is a list of some of the problems that may occur when the flash unit is used. For each item, possible causes and remedies for the problem are listed.

  • Some cameras support the AF measuring beam in the flash unit only with the camera’s central AF sensor. If a peripheral AF sensor is selected, then the AF measuring beam will not be activated in the flash unit. Activate the central AF sensor.
  • Automatic switching to the flash sync speed fails to occur.
  • The camera has a between-the-lens shutter (as do most compact cameras), Switching to sync speed is therefore unnecessary.
  • The camera operates with shutter speeds that are slower than the flash sync speed. Depending on the camera mode, there is no switch to flash sync speed (see the camera’s operating instructions).
  • The AF measuring beam of the flash unit is not activated.
  • The flash unit is not ready for firing.
  • The camera is not in „Single-AF (S)“ or „ONE SHOT“ mode.
  • The camera supports only its own internal AF measuring beam.

The shots have shadows in the bottom of the image. • Because of parallax error between lens and flash unit, close-up shots may not, depending on the focal length at the bottom of the image, be fully illuminated. Turn the wide-angle diffuser in front of the reflector.

Page 23 of the Metz Mecablitz 26 AF-2 user manual
Pagina 23 · klik om te vergroten
Pagina 23
  • The shots are too dark.
  • The subject is beyond the range of the flash unit. Note: Using bounce flash reduces the range of the flash unit.
  • The subject contains very bright or highly reflective areas. The metering system of the camera or flash unit is deceived as a result. Set manually a positive flash exposure correction at the camera, e.g. +1 EV.

The shots are too bright. • Certain minimum lighting distances must be maintained for close-up shots to avoid over-exposure. The minimum distance from the subject should be at least 10% of the maximum range. (Table of flash unit range, see page 160)

Page 24 of the Metz Mecablitz 26 AF-2 user manual — 12 Technical data Max. guide numbers at ISO 100:
Pagina 24 · klik om te vergroten
Pagina 24

12 Technical data Max. guide numbers at ISO 100:

Power supplyTwo micro AAAs (alkaline-manganese batteries, NiMH rechargeable batteries, lithium batteries)

14 with 24mm wide-angle lens 20 with 35 mm standard reflector 26 with 85 mm telephoto diffuser Illumination of the reflector (small picture format 24 x 36): 35mm 24 mm with integrated wide-angle diffuser 85 mm with telephoto diffuser

Colour temperatureCa. 5600 K
Synchronisationlow-voltage ignition
Number of flashesapprox. 100 with high-capacity alkaline-manganese

batteries approx. 110 with NiMH rechargeable batteries approx. 160 with lithium batteries.

Flash modes: Canon: E-TTL, E-TTL II, Remote-Slave mode Nikon: i-TTL, i-TTL-BL, Remote-Slave mode FUJIFILM:. .TTL Olympus:. .TTL, Remote-Slave mode Pentax: P-TTL, Remote-Slave mode Sony: Pre-flash TTL, ADI measurement, Remote-

Recycling time: approx. 0,3 s - 8 s. Vertical swivel ranges and lock-in positions of the reflector head (see fold-out page): 0° First close-up range position / “lying” on the camera for transport 20° 2nd close-up range position 40° Normal position (unit flashes in the direction of the optical axis) 90° Indirect flashing (unit flashes diagonally upwards)

Slave mode Video lightHigh-power LED

(also used for AF auxiliary light), typically 30 lux at 1 m distance, 2 brightness levels

Operating time2-5h
Page 25 of the Metz Mecablitz 26 AF-2 user manual — 12 Technical data Max. guide numbers at ISO 100:
Pagina 25 · klik om te vergroten
Pagina 25

Dimensions in mm (W x H x D) in the normal position: approx. 63 mm x 85 mm (110 mm) x 85 mm Weight: approx. 115g (without power supplies)

Disposal of batteries Do not dispose of spent batteries with domestic rubbish. Please return spent batteries to collecting points should they exist in your country! Please return only fully discharged batteries. Normally, batteries are fully discharged if: - the device they powered switches itself off and

Included: Flash unit with integrated wide-angle diffuser and tele- photo lens cover, mounting foot, brief instructions and case.

indicates "Spent Batteries". - they no longer function properly after prolonged use. To ensure short-circuit safety please cover the battery poles with adhesive tape.

13 Optional accessories • Flash unit mounting foot S60 (order No. 000000607) for Slave mode.

  • TTL-Connecting cable for Canon TCC-10 (order No. 000305118)
  • TTL-Connecting cable for Nikon TCC-20 (order No. 000305126)

We accept no liability for malfunctions of or damage to the flash unit caused by the use of accessories of other manufacturers!

Errors excepted. Subject to changes !

Page 26 of the Metz Mecablitz 26 AF-2 user manual — 12 Technical data Max. guide numbers at ISO 100:
Pagina 26 · klik om te vergroten
Pagina 26
Page 26 of the Metz Mecablitz 26 AF-2 user manual — 12 Technical data Max. guide numbers at ISO 100:
Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Metz Mecablitz 26 AF-2

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Metz Mecablitz 26 AF-2

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Metz Mecablitz 26 AF-2 handleiding-pdf

164 pagina's·519 KB·Flitsers·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…