I If, for whatever reason, the heater has
I Periodic maintenance (at least once a year,
I Since the rising air above the heater is at a
I Never use the heater to dry clothes,
I Never place objects on the heater when it
I The housing of this heater can reach high
I This heater may only be positioned and
re-lighting the appliance.
gone out, wait for at least 5 minutes before
operation of this heater.
advisable in order to ensure effective, safe
season) by an authorised person is
for example at the start of the heating
15 cm.
window ledge above the housing should be
the housing and curtains or a combustible
material. The minimum distance between
window ledge made of combustible
heater. Do not install the heater below a
must not be positioned directly above the
fairly high temperature, curtains or ‘nets’
housing.
high temperatures will develop inside the
towels, etc.; if the housing is covered, very
is working.
or place a guard around the heater.
temperatures. Be careful therefore with
installed by an authorised installer.
I Burnt dust causes an unpleasant smell and
I The heater may only be repaired using
I Use an approved gas tap to connect the
housing and the interior free from dust.
minimised by keeping the room, the
never be entirely prevented, it can be
ceilings. Although such discoloration can
also results in discoloration of walls and
original parts.
heater to the gas main.
to a windowsill (see also ‘safety’).
Do not install the external wall grille too close
periodic maintenance.
capable of being removed from the heater for
positioned in a corner as the burner has to be
The heater should preferably not be
national and local regulations.
authorised installer and in accordance with
The unit may only be installed by an
direct to the outside air.
products of combustion have to be vented
positioned against an external wall as the
This wall-mounted heater may only be
the rear panel of the heater.
building. The identification plate is located on
to the type and voltage of the current in your
the data on the identification plate correspond
to the local gas type and pressure. Check that
the data on the identification plate corresponds
technical data for this information. Check that
The pilot light is set to the correct flow. See the
identification plate, and sealed at the factory.
accordance with the category stated on the
The hearth is set to the nominal load, in
POSITIONING

towards the inside.
and must certainly not slope downwards
To avoid ingress of rain this hole must be level
be drilled.
advisable to drill this hole or arrange for it to
and have an internal diameter of 153 mm. It is
The hole for the wall vent-pipe must be round
fig. 2

the floor to the bottom of the vent-pipe hole).
plate to the floor must be 20 mm (295 mm from
distance from the bottom of this mounting
are for the mounting screws. The minimum
internal mechanism. Holes A, B and C in fig. 2
assembly unit for the wall vent and the
appliance will serve as a template and as an
The mounting plate supplied with this
Length of inlet pipe: as wall thickness.
maximum length 600 mm.
I Push the pipe through the hole in the wall
I Secure the inlet pipe to the flue grille.
I Using a spirit level check that the mounting
I Secure the mounting plate to the wall.
I Place the key bolts in the holes drilled in
I Cut the inlet pipe (largest diameter) to size.
I Drill the holes.
I Draw the holes for the key bolts and the
section on ‘positioning’.
be taken of the conditions indicated in the
appliance is to be installed, account must also
When determining the place at which the
of the wall.
advisable to mount this sheet 2 to 3 mm clear
entire surface behind the mounting plate. It is
diameter hole, must be installed to cover the
incombustible material, containing a 153 mm
wall opening must be 180 mm and a sheet of
from combustible material, the diameter of the
If the heater is installed against a wall made
from the outside.
inlet pipe.
wall grille. Then slide the grille on to the
Screw the tensioning members into the
screws.
plate is horizontal and tighten the mounting
the wall.
level.
mounting plate. Make sure that the plate is
opening for the wall vent pipe using the


I Slide the internal mechanism with the
I Place the internal mechanism with the
I Insert the outlet pipe into the opening
I Now cut the aluminium outlet pipe to size
I Make sure that the stud bolts do not
I Now insert the tensioning members through
mounting plate.
support guides around the lips on the
base resting on the lower supports.
(wall thickness + 70 mm).
top) and secure with the nuts supplied.
mounting plate (the outlet should be at the
the holes provided for this purpose in the
I Avoid straining the regulator tap when
fig. 6
I Place the casing vertically against the wall
I Slide the internal mechanism horizontally
I Slide the outlet from the internal
fig. 5
and explain it to the user.
leaks. Check the operation of the heater
connecting. Check gas connections for
the casing vertically.
projections fit into the slotted holes. Lower
and the mounting plate, so that the
tight at the top.
mechanism by screwing the support guides
horizontal supports. Secure the internal
internal mechanism engage with the
backwards until the pins on the base of the
mechanism on to the flue pipe.

fig. 7
I Replace the low-setting restrictor with the
I Replace the pilot light injection nozzle with
I Replace the main injection nozzle with the
I Replace the pressure regulator for natural
I Close the gas tap.
I Check that the values indicated on the
kit.
low-setting restrictor from the conversion
the nozzle from the conversion kit.
nozzle from the conversion kit.
(or vice versa).
gas with the adjusting screw for propane
the accompanying table.
components correspond with the values in
I Check all connections previously
I Adjust the burner pressure as per the table
I Replace the settings plate with the settings
dismantled for leaks.
appliance’s rated inlet pressure.
the supply pressure corresponds with the
whether, with the appliance turned on full,
regulator pay particular attention to
case of appliances without pressure
supplied with the conversion kit. In the
place from the conversion kit.
I Once the pilot light is lit you can select a
I If the pilot light now goes out again, the
I Press ignition button A. A spark will now
fig. 8
I Turn control knob B to position and
I Open the gas tap.
knob B.
setting between 1 and 7 with thermostat
longer.
ignition button B must be held in for a little
preceding action has to be repeated and
approximately a further 10 seconds.
ignites, then keep knob B pressed in for
ignition pressed in until the pilot light
jump to the pilot light burner. Keep the
light burner.
press it in. Gas will now flow to the pilot
A
I Turn control knob B to position . The
I If you turn the control knob to the position
heater is now completely switched off.
pilot light on during the heating season.
frost-free. You should therefore leave the
ambient temperature to keep the room
will only be switched on at a very low
position, i.e. at this setting the main burner
burn. This is also the frost-protection
between and 1, only the pilot light will
adjusting screw · pressure · pressure

abrasive cleaning agents for the housing.
water and rub dry. Never use aggressive or
After cleaning, rinse thoroughly with clean
by cleaning it regularly with soap and water.
Discoloration of the housing can be prevented
dust.
housing and the internal mechanism free of
to a minimum by keeping the room, the
never be entirely avoided, it can be restricted
ceilings. Although such discoloration can
also results in discoloration of walls and
Burnt dust gives off an unpleasant smell and
the burner can be cleaned.
Once the heater has cooled down sufficiently,
-the flue gas exhaust.
Clean (if necessary):
properly.
function properly and that the burner ignites
-the regulator and the thermocouple circuit
-the gas supply is airtight;
Check that:
annually by an authorised installer.
The heater should be cleaned and checked
- The thermocouple contact does not engage
- The pilot light is dirty.
- Insufficient gas pressure.
- Air in supply pipe (after appliance has been
Causes:
Heater fails to light or extinguish.
> Check the thermocouple circuit.
properly.
> Clean the burner carefully with a vacuum
> Check that the gas tap is open and check
> Vent.
out of operation).
cleaner.
the gas line to see if it is dirty.
local authorities.
discarded appliances can be obtained from the
Information on how to responsibly dispose of
regulations.
responsibly and in conformity with government
These materials should be disposed
- paper.
- CFC-free foam (soft);
materials:
packaging could include the following
The appliance packaging is recyclable. The
9 FAULTS