2 SAFETY

I If, for whatever reason, the heater has

I Periodic maintenance (at least once a year,

I Since the rising air above the heater is at a

I Never use the heater to dry clothes,

I Never place objects on the heater when it

I The housing of this heater can reach high

I This heater may only be positioned and

safety

re-lighting the appliance.

gone out, wait for at least 5 minutes before

operation of this heater.

advisable in order to ensure effective, safe

season) by an authorised person is

for example at the start of the heating

15 cm.

window ledge above the housing should be

the housing and curtains or a combustible

material. The minimum distance between

window ledge made of combustible

heater. Do not install the heater below a

must not be positioned directly above the

fairly high temperature, curtains or ‘nets’

housing.

high temperatures will develop inside the

towels, etc.; if the housing is covered, very

is working.

or place a guard around the heater.

childrenkeep them away from the heater

temperatures. Be careful therefore with

installed by an authorised installer.

I Burnt dust causes an unpleasant smell and

I The heater may only be repaired using

I Use an approved gas tap to connect the

housing and the interior free from dust.

minimised by keeping the room, the

never be entirely prevented, it can be

ceilings. Although such discoloration can

also results in discoloration of walls and

original parts.

heater to the gas main.

to a windowsill (see also ‘safety’).

Do not install the external wall grille too close

periodic maintenance.

capable of being removed from the heater for

positioned in a corner as the burner has to be

The heater should preferably not be

national and local regulations.

authorised installer and in accordance with

The unit may only be installed by an

direct to the outside air.

products of combustion have to be vented

positioned against an external wall as the

This wall-mounted heater may only be

positioning

the rear panel of the heater.

building. The identification plate is located on

to the type and voltage of the current in your

the data on the identification plate correspond

to the local gas type and pressure. Check that

the data on the identification plate corresponds

technical data for this information. Check that

The pilot light is set to the correct flow. See the

identification plate, and sealed at the factory.

accordance with the category stated on the

The hearth is set to the nominal load, in

gas type and pressure

POSITIONING

Page 3 of the Pelgrim GWH 4 user manual — INSTALLATION
Pagina 3 · klik om te vergroten
Pagina 3

4 INSTALLATION

towards the inside.

and must certainly not slope downwards

To avoid ingress of rain this hole must be level

be drilled.

advisable to drill this hole or arrange for it to

and have an internal diameter of 153 mm. It is

The hole for the wall vent-pipe must be round

fig. 2

Pelgrim GWH 4 — 4 INSTALLATION diagram (page 3)
Afb. 1

the floor to the bottom of the vent-pipe hole).

plate to the floor must be 20 mm (295 mm from

distance from the bottom of this mounting

are for the mounting screws. The minimum

internal mechanism. Holes A, B and C in fig. 2

assembly unit for the wall vent and the

appliance will serve as a template and as an

The mounting plate supplied with this

installing the appliance

Length of outlet pipewall thickness + 70 mm,

Length of inlet pipe: as wall thickness.

Wall thicknessminimum 70 mm

length of inlet and outlet pipe

maximum length 600 mm.

I Push the pipe through the hole in the wall

I Secure the inlet pipe to the flue grille.

I Using a spirit level check that the mounting

I Secure the mounting plate to the wall.

I Place the key bolts in the holes drilled in

I Cut the inlet pipe (largest diameter) to size.

I Drill the holes.

I Draw the holes for the key bolts and the

section on ‘positioning’.

be taken of the conditions indicated in the

appliance is to be installed, account must also

When determining the place at which the

of the wall.

advisable to mount this sheet 2 to 3 mm clear

entire surface behind the mounting plate. It is

diameter hole, must be installed to cover the

incombustible material, containing a 153 mm

wall opening must be 180 mm and a sheet of

from combustible material, the diameter of the

If the heater is installed against a wall made

from the outside.

inlet pipe.

wall grille. Then slide the grille on to the

Screw the tensioning members into the

screws.

plate is horizontal and tighten the mounting

the wall.

level.

mounting plate. Make sure that the plate is

opening for the wall vent pipe using the

Pelgrim GWH 4 — length of inlet and outlet pipe diagram (page 3)
Afb. 2 · length of inlet and outlet pipe
Pelgrim GWH 4 — length of inlet and outlet pipe diagram (page 3)
Afb. 3 · length of inlet and outlet pipe

I Slide the internal mechanism with the

I Place the internal mechanism with the

I Insert the outlet pipe into the opening

I Now cut the aluminium outlet pipe to size

I Make sure that the stud bolts do not

I Now insert the tensioning members through

mounting plate.

support guides around the lips on the

base resting on the lower supports.

(wall thickness + 70 mm).

top) and secure with the nuts supplied.

mounting plate (the outlet should be at the

the holes provided for this purpose in the

I Avoid straining the regulator tap when

connection to the gas supply

fig. 6

I Place the casing vertically against the wall

I Slide the internal mechanism horizontally

I Slide the outlet from the internal

fig. 5

and explain it to the user.

leaks. Check the operation of the heater

connecting. Check gas connections for

the casing vertically.

projections fit into the slotted holes. Lower

and the mounting plate, so that the

tight at the top.

mechanism by screwing the support guides

horizontal supports. Secure the internal

internal mechanism engage with the

backwards until the pins on the base of the

mechanism on to the flue pipe.

INSTALLATION

Page 4 of the Pelgrim GWH 4 user manual — USE
Pagina 4 · klik om te vergroten
Pagina 4

CONVERSION

fig. 7

11. Taper ring and coupling nut
10. Injection nozzle
9. Main burner
8. Burner pipe
7. Supply pipe
6. Mounting bracket
5. Pilot light
4. Low-setting restrictor
3. Pressure regulator or
2. Measurement point for supply
1. Measurement point for burner

I Replace the low-setting restrictor with the

I Replace the pilot light injection nozzle with

I Replace the main injection nozzle with the

I Replace the pressure regulator for natural

I Close the gas tap.

I Check that the values indicated on the

converting to a different type of gas

kit.

low-setting restrictor from the conversion

the nozzle from the conversion kit.

nozzle from the conversion kit.

(or vice versa).

gas with the adjusting screw for propane

the accompanying table.

components correspond with the values in

I Check all connections previously

I Adjust the burner pressure as per the table

I Replace the settings plate with the settings

dismantled for leaks.

appliance’s rated inlet pressure.

the supply pressure corresponds with the

whether, with the appliance turned on full,

regulator pay particular attention to

case of appliances without pressure

supplied with the conversion kit. In the

place from the conversion kit.

I Once the pilot light is lit you can select a

I If the pilot light now goes out again, the

I Press ignition button A. A spark will now

fig. 8

I Turn control knob B to position and

I Open the gas tap.

lighting

knob B.

setting between 1 and 7 with thermostat

longer.

ignition button B must be held in for a little

preceding action has to be repeated and

approximately a further 10 seconds.

ignites, then keep knob B pressed in for

ignition pressed in until the pilot light

jump to the pilot light burner. Keep the

light burner.

press it in. Gas will now flow to the pilot

B

A

I Turn control knob B to position . The

I If you turn the control knob to the position

switching off

heater is now completely switched off.

pilot light on during the heating season.

frost-free. You should therefore leave the

ambient temperature to keep the room

will only be switched on at a very low

position, i.e. at this setting the main burner

burn. This is also the frost-protection

between and 1, only the pilot light will

USE

adjusting screw · pressure · pressure

Page 5 of the Pelgrim GWH 4 user manual — disposing of the packaging and appliancel
Pagina 5 · klik om te vergroten
Pagina 5

8 CLEANING

abrasive cleaning agents for the housing.

water and rub dry. Never use aggressive or

After cleaning, rinse thoroughly with clean

by cleaning it regularly with soap and water.

Discoloration of the housing can be prevented

dust.

housing and the internal mechanism free of

to a minimum by keeping the room, the

never be entirely avoided, it can be restricted

ceilings. Although such discoloration can

also results in discoloration of walls and

Burnt dust gives off an unpleasant smell and

the burner can be cleaned.

Once the heater has cooled down sufficiently,

cleaning the burner

-the flue gas exhaust.

Clean (if necessary):

properly.

function properly and that the burner ignites

-the regulator and the thermocouple circuit

-the gas supply is airtight;

Check that:

annually by an authorised installer.

The heater should be cleaned and checked

maintenance and cleaning

- The thermocouple contact does not engage

- The pilot light is dirty.

- Insufficient gas pressure.

- Air in supply pipe (after appliance has been

Causes:

Heater fails to light or extinguish.

faults

> Check the thermocouple circuit.

properly.

> Clean the burner carefully with a vacuum

> Check that the gas tap is open and check

> Vent.

out of operation).

cleaner.

the gas line to see if it is dirty.

local authorities.

discarded appliances can be obtained from the

Information on how to responsibly dispose of

regulations.

responsibly and in conformity with government

These materials should be disposed

- paper.

- CFC-free foam (soft);

materials:

packaging could include the following

The appliance packaging is recyclable. The

disposing of the packaging and appliancel

9 FAULTS

Show 6 more labels / short text on this page
-the combustion chamber; · -the burner; · -the pilot system; · - plastic; · - wood · - card board;

Vraag stellen over de Pelgrim GWH 4

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Pelgrim GWH 4

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Pelgrim GWH 4 handleiding-pdf

21 pagina's·911 KB·Kachel·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…