NL
Qlima logo
Officiële handleiding

Qlima D 630 P

120 pagina's·911 KB·Luchtbevochtiger/-ontvochtiger·PDF·ENJA
Qlima D 630 P
Inhoudsopgave 17 secties IMPORTANT COMPONENTS · SAFETY INSTRUCTIONS · REQUIRED DISTANCE · CONTROL PANEL · … TonenVerbergen
Page 1 of the Qlima D 630 P user manual
Pagina 1 · klik om te vergroten
Pagina 1

Congratulations with the purchase of your dehumidifier. You have acquired a high quality

product which will give you many years of pleasure, if you use it responsibly. Please read

the user’s manual first in order to ensure the optimum life span of your dehumidifier. On

behalf of the manufacturer, we provide a two-year warranty on material- or manufacturing

defects.

Enjoy your dehumidifier.

PVG Holding B.V.

1 PLEASE READ THE USER’S MANUAL FIRST.

2 IF YOU HAVE ANY DOUBTS, CONSULT YOUR DEALER.

Dear Sir, Madam, · Yours sincerely, · Customer Service Department

Page 2 of the Qlima D 630 P user manual — E
Pagina 2 · klik om te vergroten
Pagina 2

IMPORTANT COMPONENTS

A

B

Qlima D 630 P — IMPORTANT COMPONENTS diagram (page 2)
Afb. 1

E

F

G

H

Show 9 more labels / short text on this page
Supply cord · Tank · Continuous drainage · Filter screen · Back shell · Air outlet · Top cover · Front shell · Water indicator
Page 3 of the Qlima D 630 P user manual — SAFETY INSTRUCTIONS
Pagina 3 · klik om te vergroten
Pagina 3

SAFETY INSTRUCTIONS

Read this user manual carefully before using the appliance and keep it for future reference. Install this device only when it complies with local/national leg- islation, ordinances and standards. This product is intended to be used as a dehumidifier in residential houses and is only suitable for use in dry locations, in normal household conditions, indoors in living room, kitchen and garage. This unit is only suitable for earthed sockets, connection voltage 220-240 V. / ~50 Hz.

  • GENERAL
  • To obtain optimum performance from your dehumidifier, do not place it near a radiator or any other heat source.
  • Ensure that all windows are closed in order to achieve maximum efficiency.
  • The capacity of the dehumidifier depends on the temperature and the humidity in the room. At lower temperatures, less moisture will be removed.
  • Ensure that the screen filter is kept clean. This prevents unnecessary power consumption and guarantees optimum efficiency.
  • If the power supply has been interrupted, the dehumidifier will restart after three minutes. The automatic delay protects the compressor.
Page 4 of the Qlima D 630 P user manual — SAFETY INSTRUCTIONS
Pagina 4 · klik om te vergroten
Pagina 4
  • Before connecting the unit, check the following:
  • The voltage supply must correspond with the mains voltage stated on the rating label.
  • The socket and power supply must be suitable for the current stated on the rating label.
  • The plug on the cable of the device must fit into the wall socket.
  • The device must be placed on a flat and stable surface.

The electricity supply to the device must be checked by a recognised professional if you have any doubts regarding the compatibility.

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • This device is manufactured according to CE safety standards. Nevertheless, you must take care, as with any other electrical device.
  • Do not cover the air inlet and outlet grill.
  • Empty the water reservoir before moving the unit.
  • Never allow the device to come into contact with chemicals.
  • Never spray the unit with or submerge in water
  • Do not insert objects into the openings of the unit.
  • Always remove the plug from the electric power supply before cleaning or replacing the unit or components of the unit.
  • Never use an extension cable to connect the device to the electric power supply. If there is no suitable, earthed wall socket available, have one installed by a recognised electrician.
Page 5 of the Qlima D 630 P user manual — SAFETY INSTRUCTIONS
Pagina 5 · klik om te vergroten
Pagina 5
  • Children should be supervised to ensure that they do not play with the appliance.
  • Have any repairs only carried out by a recognised service engineer or your supplier. Follow the instructions for use and maintenance as indicated in the user manual of this device.
  • Always remove the plug of the unit from the wall socket when it is not in use.
  • A damaged power cord or plug must always be replaced by a recognised electrician or your supplier.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • If the mains cord is damaged, you must have it replaced by a service centre authorised by Qlima or similarly qualified persons in order to avoid a hazard. G
  • ATTENTION!
  • Never use the device with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or allow it to come into contact with sharp edges.
  • Failing to follow the instructions may lead to nullification of the guarantee on this device.
  • Do not place the dehumidifier in bathrooms or in other places where it is likely that water could be sprayed on the dehumidifier.
Page 6 of the Qlima D 630 P user manual — SAFETY INSTRUCTIONS
Pagina 6 · klik om te vergroten
Pagina 6

Specific information regarding appliances with R 290 refrigerant gas.

  • Thoroughly read all of the warnings.
  • When defrosting and cleaning the aplliance , do not use any tools other than those recommended by the manufacturing company.
  • The appliance must be placed in an area without any continuously sources of ignition (for example: open flames , gas or electrical appliances in operation).
  • Do not puncture and do not burn.
  • This appliance contains Y g (see rating label back of unit ) of R290 refrigerant gas.
  • R290 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part of the refrigerant circuit. Be aware the refrigerants may not contain an odour.
  • If the appliance is installed, operated or stored in a nonventilated area, the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
  • The appliance must be stored in such a way as to prevent mechanical failure.
  • Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry.
  • Repairs must be performed based on the recommendation from the manufacturing company. Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants.
Page 7 of the Qlima D 630 P user manual — CONTROL PANEL
Pagina 7 · klik om te vergroten
Pagina 7

REQUIRED DISTANCE

Qlima D 630 P — REQUIRED DISTANCE diagram (page 7)
Afb. 2

Respect the required distance of the device to walls and other objects.

CONTROL PANEL

6. 7. 8. 9.
1. 2. 3. 4. 5.
1. POWER (On/Off): The unit can be switched on or off. After boot, the current humidity

humidity will be displayed with the defaults of continuous mode “CO”, and the

compressor will then start immediately for dehumidification with POWER indicator

lamp lit (when the compressor stops,it flashes).

2. SPEED: Fan speed can be switched between high or low.

degree, the wind speed is fixed.

3. UP-DOWN (HUM+ HUM-) Set the required humidity among the follows: “CO”

(continuous), “30%”, “50”, “35%”, “40%”, “45%”, “50%” “85”, “90”, “AU”

(comfort), “CO” (continuous) cycle. The default mode is “CO”.

humidity, the indicator “Cº” being for temperature and “%” for humidity.

4. TIMER: Timing setting.

A. In the power-on state, press the TIMER key to set the timer for the scheduled

shutdown. In the off state, press the TIMER key to set the timer and when to start

the dehumidifier.

B. Regular time range: 01~24 hours, timing setting: 000102 232400 cycle.

C. When the timing is set to power on, the timing setting is completed and the timing

is displayed. When the timing is set to off, the timing setting is completed and the

humidity is displayed after 5 seconds.

5. MODE key: mode conversion: dry clothes, fan, dehumidification.
6. Pump automatic pumping function On/Off button: PUMP indicator, continuous

drainage opening and closing.

7. Swing: On/Off control of the “Swing” function.

After machine turns on, press this key, the louver will swing continuously left and

right; by pressing this button again the movement will stop and the louver remain in

that position.

8. Child lock: Long key This key is 5 seconds for child lock switch selection.

After child lock is turned on, all button operations except child lock buttons cannot

be operated.

9. Hidden display: Dual 8-screen display on synchronous main operation display panel.

dimmed.

20 cm · 20 cm

Page 8 of the Qlima D 630 P user manual — OPERATION
Pagina 8 · klik om te vergroten
Pagina 8

OPERATION

1. Humidity automatic control operation function:

A. When “CO” (continuous) operation is set to dehumidify, the dehumidifier will

continue to operate regardless of the humidity level.

B. If the indoor humidity is higher than or equal to 3% or more of the set humidity,

the compressor and fan will run. The indicator light of the compressor will be on.

C. After the humidity in the room is dehumidified, when the humidity drops below

2% of the set humidity, the compressor is turned off and the dehumidification is

stopped. The indicator lamp (OK lamp) that reaches the humidity is on.

D. If the dehumidifier stops dehumidifying and the humidity in the room rises above

or equal to 3% or more of the set humidity, if the compressor has passed the

three-minute protection status, the compressor will start dehumidifying.

E. According to the above cycle operation, the indoor humidity can be maintained

at the set humidity.

2. Comfort (shows “AU”) function:

A. Below 5°C at room temperature, the dehumidifier stops;

B. 5 °C ≤ room temperature ≤ 20 °C, automatic selection set 60% humidity;

C. 20°C

D. Room temperature> 27 °C, automatic selection set 50% humidity.

3. Drying function: (CLOTH light):

A. When this function is enabled, the dehumidifier will continue to operate

(compressor, fan operation) regardless of the humidity level when the “CO”

(continuous) operation dehumidifies.

B. The wind speed is locked at high speed and cannot be adjusted.

4. Fan:

A. The compressor does not work.

B. The fan can choose two operating modes: high wind and low wind.

C. Humidity setting button cannot be pressed in fan mode

5. Full water protection:

A. When the full water lasts for 3 seconds , the controller stops working and all

outputs are turned off. The full water indicator is on (FULL, the buzzer sounds 15

rings. Press any key, the bee The alarm will stop immediately.

B. When the full water fault is removed, the original machine’s operating status is

restored (the compressor must be protected by 3 minutes)

6. Defrost function:

A. When it is in defrosting, the compressor is turned off, the fan is defrosted by high

winds, and the defrost indicator lights up (DEF).

B. When the room temperature is less than or equal to 16°C, the temperature of the

coil is not detected. According to the room temperature action, it is as follows:

Room temperature

When 5°C ≤ room temperature ≤ 12°C, the compressor is running for 30 minutes

and the defrost is stopped for 10 minutes.

When 12°C< room temperature ≤ 16°C, the compressor is running for 45 minutes

and the defrost is stopped for 10 minutes

C. When the room temperature is greater than 16°C, the temperature of the coil

is detected, and the operation is performed according to the temperature of

the coil, as followsWhen the compressor is running for 30 minutes, the coil
Page 9 of the Qlima D 630 P user manual — CAUTION
Pagina 9 · klik om te vergroten
Pagina 9

temperature is detected. If the coil temperature is ≤ 1°C, the defrosting is stopped

for 10 minutes.

7. Compressor delay protection:

A. Every time the boot compressor is allowed to start immediately.

B. After the compressor is shut down, start it again, with at least a 3-minute interval.

8. Water pump settings:

A. When you press the pump automatic pumping function ON/OFF button (PUMP

button), the automatic pumping function of the pump is turned on, and the

corresponding indicator lamp (PUMP lamp) is on.

WATER DRAINAGE

When the drainage tank is full, the tank full indicator light will turn on, the operation will

stop automatically and the buzzer will beep 15 times to alert the user, that the water need

to be emptied from the drainage tank.

EMPTY TANK

1. Gently press on the sides of the tank and pull the tank out with both hands.
Qlima D 630 P — EMPTY TANK diagram (page 9)
Afb. 3
2. Empty the water in the tank.
Qlima D 630 P — EMPTY TANK diagram (page 9)
Afb. 4

CAUTION

1. Do not remove the floater in the water tank, otherwise, the water sensor will not

be able to sense the water level so that it can not operate normally.

Page 10 of the Qlima D 630 P user manual — CONTINUOUS DRAINAGE
Pagina 10 · klik om te vergroten
Pagina 10
Qlima D 630 P — CONTINUOUS DRAINAGE diagram (page 10)
Afb. 5
2. If the tank is dirty, use cold water or warm water cleaning. It is not possible to use

detergents, steel velvet, chemical treated dusting cloth, gasoline, benzene, thinner

or other solvents, because it may damage the water tank and cause water leakage.

3. When putting into the tank, press the tank tightly with both hands. If the water

tank is not placed, the full water sensor will still be activated, and the dehumidi-

fier will not work.

Qlima D 630 P — CONTINUOUS DRAINAGE diagram (page 10)
Afb. 6

CONTINUOUS DRAINAGE

The dehumidifier has a continuous drainage hole, using a plastic tube (diameter 10mm)

inserted in partition drainage hole, then outgoing from the tank side. When the water

tank should be installed in place,and the drainage pipe straightened out, the water can be

drained from the machine through the drainage hole.

Qlima D 630 P — CONTINUOUS DRAINAGE diagram (page 10)
Afb. 7
Qlima D 630 P — CONTINUOUS DRAINAGE diagram (page 10)
Afb. 8
Page 11 of the Qlima D 630 P user manual — B. TO CLEAN THE AIR FILTER
Pagina 11 · klik om te vergroten
Pagina 11

MAINTENANCE

CLEANING THE DEHUMIDIFIER

A. TO CLEAN THE BODY

1Wipe it with a soft damp cloth.

B. TO CLEAN THE AIR FILTER

1. Pull up the filter.
Qlima D 630 P — B. TO CLEAN THE AIR FILTER diagram (page 11)
Afb. 9
2. Clean Filter: Use a vacuum cleaner to gently absorb dust on filter screen surface. If

very dirty, use warm water and gentle detergent. Keep dry.

Qlima D 630 P — B. TO CLEAN THE AIR FILTER diagram (page 11)
Afb. 10
Qlima D 630 P — B. TO CLEAN THE AIR FILTER diagram (page 11)
Afb. 11
3. Filter Installation: Insert the filter into the machine, and push the two hooks of the

filter in place.

Qlima D 630 P — B. TO CLEAN THE AIR FILTER diagram (page 11)
Afb. 12
Page 12 of the Qlima D 630 P user manual — CONDITIONS OF WARRANTY
Pagina 12 · klik om te vergroten
Pagina 12

STORAGE

If the machine will not be used for a long period of time, take the following steps:

1. Remove the plug from the socket and empty the container. Allow the container and

the dehumidifier to dry completely.

2. Clean the air filter.
3. Store the device in a dust-free location, preferably covered with a sheet of plastic.

TROUBLE SHOOTING

Check the following before contacting technical support:

Failure Potential causes of failure Solution

Is the power line properly con- nected??

Connect the plug and socket well.

Is the full water indicator light? (water tank full or not put in place)

The machine doesn't work.

Drain the water in the tank and put it in place.

Is the room temperature is above 35 degrees or under 5 degrees? The protection device is started and the machine cannot work.

Clean the filter screen according to the cleaning instructions of dehumidifier.

Is the filter blocked?

Dehumidification func- tion can not start.

Is the air inlet or outlet blocked? Remove the obstruction from the air inlet or outlet.

Clean the filter screen according to the cleaning instructions of dehumidifier.

Without wind Is the filter plugged?

Is the machine tilted? Move the machine to a flat, strong position.

It's noisy at work?

Clean the filter screen according to the cleaning instructions of dehumidifier.

Is the filter blocked?

E1 Code Coil sensor short circuit or open circuit

Check whether the line is loose or replace the coil sensor.

CONDITIONS OF WARRANTY

There is a two-year warranty on your dehumidifier from the date of purchase. All material

or manufacturing defects will be repaired free of charge.

The following applies:

Page 13 of the Qlima D 630 P user manual — TECHNICAL SPECIFICATIONS
Pagina 13 · klik om te vergroten
Pagina 13
  • All claims for compensation, including consequential damage, will not be entertained.
  • Any repairs or replacement of components during the warranty period will not result

in an extension of the warranty period.

  • The warranty will expire if any alterations have been made, not genuine components

have been fitted or if the dehumidifier has been repaired by a third party.

  • Components subject to normal wear and tear, such as the air filter, are not covered by

the warranty.

  • The warranty is only valid on presentation of the original, unaltered, and date-

stamped purchase receipt.

  • The warranty does not cover damage caused by actions that deviate from those as

described in the user’s manual or by neglect.

  • Transportation costs and the risks involved during the transportation of the

dehumidifier or components shall always be for the account of the purchaser.

To prevent unnecessary expenses, we recommend that you always carefully read the user’s

manual first. If this does not provide a solution, take the dehumidifier to your distributor

for repair.

TECHNICAL SPECIFICATIONS

Qlima D 630 P — TECHNICAL SPECIFICATIONS diagram (page 13)
Afb. 13

Dehumidifying capacity (moisture removal at 30ºC, 80%RH) L / 24h 30

Dehumidifying capacity (moisture removal at 27ºC, 60%RH) L / 24h 15

For rooms up to * m3 160 - 200

Dimensions (w x d x h) mm 371 x 251 x 595

* To be used as indication

Subject to change without prior notice.

Page 14 of the Qlima D 630 P user manual — TECHNICAL SPECIFICATIONS
Pagina 14 · klik om te vergroten
Pagina 14

Do not dispose of electrical appliances as unsorted municipal waste, use separate

collection facilities. Contact your local government for information regarding the

collection systems available. If electrical appliances are disposed of in landfills or

dumps, hazardous substances can leak into the groundwater and get into the

food chain, damaging your health and well-being. When replacing old appliances

with new once, the retailer is legally obligated to take back your old appliance for

disposal at least for free of charge.

This equipment contains R290 refrigerant in the amount as stated in the table

above. Do not vent R290 into atmosphere: R290, is a fluorinated greenhouse gas

with a Global Warming Potential (GWP) = 3

Vraag stellen over de Qlima D 630 P

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.