Congratulations with the purchase of your dehumidifier. You have acquired a high quality
product which will give you many years of pleasure, if you use it responsibly. Please read
the user’s manual first in order to ensure the optimum life span of your dehumidifier. On
behalf of the manufacturer, we provide a two-year warranty on material- or manufacturing
defects.
Enjoy your dehumidifier.
PVG Holding B.V.
1 PLEASE READ THE USER’S MANUAL FIRST.
2 IF YOU HAVE ANY DOUBTS, CONSULT YOUR DEALER.
Dear Sir, Madam, · Yours sincerely, · Customer Service Department

A
B

F
G
H

Read this user manual carefully before using the appliance and keep it for future reference. Install this device only when it complies with local/national leg- islation, ordinances and standards. This product is intended to be used as a dehumidifier in residential houses and is only suitable for use in dry locations, in normal household conditions, indoors in living room, kitchen and garage. This unit is only suitable for earthed sockets, connection voltage 220-240 V. / ~50 Hz.

The electricity supply to the device must be checked by a recognised professional if you have any doubts regarding the compatibility.


Specific information regarding appliances with R 290 refrigerant gas.


Respect the required distance of the device to walls and other objects.
humidity will be displayed with the defaults of continuous mode “CO”, and the
compressor will then start immediately for dehumidification with POWER indicator
lamp lit (when the compressor stops,it flashes).
degree, the wind speed is fixed.
(continuous), “30%”, “50”, “35%”, “40%”, “45%”, “50%” “85”, “90”, “AU”
(comfort), “CO” (continuous) cycle. The default mode is “CO”.
humidity, the indicator “Cº” being for temperature and “%” for humidity.
A. In the power-on state, press the TIMER key to set the timer for the scheduled
shutdown. In the off state, press the TIMER key to set the timer and when to start
the dehumidifier.
B. Regular time range: 01~24 hours, timing setting: 000102 232400 cycle.
C. When the timing is set to power on, the timing setting is completed and the timing
is displayed. When the timing is set to off, the timing setting is completed and the
humidity is displayed after 5 seconds.
drainage opening and closing.
After machine turns on, press this key, the louver will swing continuously left and
right; by pressing this button again the movement will stop and the louver remain in
that position.
After child lock is turned on, all button operations except child lock buttons cannot
be operated.
dimmed.
20 cm · 20 cm

A. When “CO” (continuous) operation is set to dehumidify, the dehumidifier will
continue to operate regardless of the humidity level.
B. If the indoor humidity is higher than or equal to 3% or more of the set humidity,
the compressor and fan will run. The indicator light of the compressor will be on.
C. After the humidity in the room is dehumidified, when the humidity drops below
2% of the set humidity, the compressor is turned off and the dehumidification is
stopped. The indicator lamp (OK lamp) that reaches the humidity is on.
D. If the dehumidifier stops dehumidifying and the humidity in the room rises above
or equal to 3% or more of the set humidity, if the compressor has passed the
three-minute protection status, the compressor will start dehumidifying.
E. According to the above cycle operation, the indoor humidity can be maintained
at the set humidity.
A. Below 5°C at room temperature, the dehumidifier stops;
B. 5 °C ≤ room temperature ≤ 20 °C, automatic selection set 60% humidity;
C. 20°C
D. Room temperature> 27 °C, automatic selection set 50% humidity.
A. When this function is enabled, the dehumidifier will continue to operate
(compressor, fan operation) regardless of the humidity level when the “CO”
(continuous) operation dehumidifies.
B. The wind speed is locked at high speed and cannot be adjusted.
A. The compressor does not work.
B. The fan can choose two operating modes: high wind and low wind.
C. Humidity setting button cannot be pressed in fan mode
A. When the full water lasts for 3 seconds , the controller stops working and all
outputs are turned off. The full water indicator is on (FULL, the buzzer sounds 15
rings. Press any key, the bee The alarm will stop immediately.
B. When the full water fault is removed, the original machine’s operating status is
restored (the compressor must be protected by 3 minutes)
A. When it is in defrosting, the compressor is turned off, the fan is defrosted by high
winds, and the defrost indicator lights up (DEF).
B. When the room temperature is less than or equal to 16°C, the temperature of the
coil is not detected. According to the room temperature action, it is as follows:
Room temperature
When 5°C ≤ room temperature ≤ 12°C, the compressor is running for 30 minutes
and the defrost is stopped for 10 minutes.
When 12°C< room temperature ≤ 16°C, the compressor is running for 45 minutes
and the defrost is stopped for 10 minutes
C. When the room temperature is greater than 16°C, the temperature of the coil
is detected, and the operation is performed according to the temperature of

temperature is detected. If the coil temperature is ≤ 1°C, the defrosting is stopped
for 10 minutes.
A. Every time the boot compressor is allowed to start immediately.
B. After the compressor is shut down, start it again, with at least a 3-minute interval.
A. When you press the pump automatic pumping function ON/OFF button (PUMP
button), the automatic pumping function of the pump is turned on, and the
corresponding indicator lamp (PUMP lamp) is on.
When the drainage tank is full, the tank full indicator light will turn on, the operation will
stop automatically and the buzzer will beep 15 times to alert the user, that the water need
to be emptied from the drainage tank.


be able to sense the water level so that it can not operate normally.


detergents, steel velvet, chemical treated dusting cloth, gasoline, benzene, thinner
or other solvents, because it may damage the water tank and cause water leakage.
tank is not placed, the full water sensor will still be activated, and the dehumidi-
fier will not work.

The dehumidifier has a continuous drainage hole, using a plastic tube (diameter 10mm)
inserted in partition drainage hole, then outgoing from the tank side. When the water
tank should be installed in place,and the drainage pipe straightened out, the water can be
drained from the machine through the drainage hole.



A. TO CLEAN THE BODY
1Wipe it with a soft damp cloth.

very dirty, use warm water and gentle detergent. Keep dry.


filter in place.


If the machine will not be used for a long period of time, take the following steps:
the dehumidifier to dry completely.
Check the following before contacting technical support:
Failure Potential causes of failure Solution
Is the power line properly con- nected??
Connect the plug and socket well.
Is the full water indicator light? (water tank full or not put in place)
The machine doesn't work.
Drain the water in the tank and put it in place.
Is the room temperature is above 35 degrees or under 5 degrees? The protection device is started and the machine cannot work.
Clean the filter screen according to the cleaning instructions of dehumidifier.
Is the filter blocked?
Dehumidification func- tion can not start.
Is the air inlet or outlet blocked? Remove the obstruction from the air inlet or outlet.
Clean the filter screen according to the cleaning instructions of dehumidifier.
Without wind Is the filter plugged?
Is the machine tilted? Move the machine to a flat, strong position.
It's noisy at work?
Clean the filter screen according to the cleaning instructions of dehumidifier.
Is the filter blocked?
E1 Code Coil sensor short circuit or open circuit
Check whether the line is loose or replace the coil sensor.
There is a two-year warranty on your dehumidifier from the date of purchase. All material
or manufacturing defects will be repaired free of charge.
The following applies:

in an extension of the warranty period.
have been fitted or if the dehumidifier has been repaired by a third party.
the warranty.
stamped purchase receipt.
described in the user’s manual or by neglect.
dehumidifier or components shall always be for the account of the purchaser.
To prevent unnecessary expenses, we recommend that you always carefully read the user’s
manual first. If this does not provide a solution, take the dehumidifier to your distributor
for repair.

Dehumidifying capacity (moisture removal at 30ºC, 80%RH) L / 24h 30
Dehumidifying capacity (moisture removal at 27ºC, 60%RH) L / 24h 15
For rooms up to * m3 160 - 200
Dimensions (w x d x h) mm 371 x 251 x 595
* To be used as indication
Subject to change without prior notice.

Do not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities. Contact your local government for information regarding the
collection systems available. If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the groundwater and get into the
food chain, damaging your health and well-being. When replacing old appliances
with new once, the retailer is legally obligated to take back your old appliance for
disposal at least for free of charge.
This equipment contains R290 refrigerant in the amount as stated in the table
above. Do not vent R290 into atmosphere: R290, is a fluorinated greenhouse gas
with a Global Warming Potential (GWP) = 3
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.