NL
Quickie logo
Officiële handleiding

Quickie Argon 2

72 pagina's·1.7 MB·Rolstoel·PDF·ENDEITJA
Quickie Argon 2
Inhoudsopgave 49 secties WHEELCHAIR FAUTEUIL ROULANT ROLSTOEL · DIRECTIONS FOR USE NOTICE D’UTILISATION GEBRUIKERSHANDLEIDING · Argon 2 · 000690386.01 · … TonenVerbergen
Page 1 of the Quickie Argon 2 user manual — 000690386.01
Pagina 1 · klik om te vergroten
Pagina 1

WHEELCHAIR FAUTEUIL ROULANT ROLSTOEL

Quickie Argon 2 — WHEELCHAIR FAUTEUIL ROULANT ROLSTOEL diagram (page 1)
Afb. 1

DIRECTIONS FOR USE NOTICE D’UTILISATION GEBRUIKERSHANDLEIDING

Argon 2

Quickie Argon 2 — DIRECTIONS FOR USE NOTICE D’UTILISATION GEBRUIKERSHANDLEIDING diagram (page 1)
Afb. 2

000690386.01

Page 3 of the Quickie Argon 2 user manual — WHEELCHAIR FAUTEUIL ROULANT ROLSTOEL
Pagina 3 · klik om te vergroten
Pagina 3
Page 3 of the Quickie Argon 2 user manual — WHEELCHAIR FAUTEUIL ROULANT ROLSTOEL
Page 4 of the Quickie Argon 2 user manual — mm ° kg
Pagina 4 · klik om te vergroten
Pagina 4

mm ° kg

Quickie Argon 2 — mm ° kg diagram (page 4)
Afb. 3 · mm ° kg
1050 700760 5601120 690500 220 520 440500 300365 230567 540 450 250500 300MAX mm MIN mm 710 510325 275+11 -100MAX mm MIN mm 10° 0°10° 0°10° 0°< MAX < MIN. X°15° 0°X°+15° -31°X°100° 92°< MAX < MIN 10,0 6,915,0 9,0Kg MAX140 ---2,1 KGMAX kg MIN kg
Page 5 of the Quickie Argon 2 user manual — mm ° kg
Pagina 5 · klik om te vergroten
Pagina 5
3 2 1 111 mm× √ 1,0 cmh" 44454647484950 3” 75 mm1√×××√××× 1×××√×××× 2√××××××× 2××√××××× 3×××××××× 4” 98 mm1√×××××√× 1×××××√×× 2√×××√××× 2×××√×××× 3√××××××× 3××√××××× 5” 124 mm1√××××××√ 1×××××√× 2×××××√×× 3××××××××
Quickie Argon 2 — mm ° kg diagram (page 5)
Afb. 4 · mm ° kg
Page 6 of the Quickie Argon 2 user manual — mm ° kg
Pagina 6 · klik om te vergroten
Pagina 6
Quickie Argon 2 — mm ° kg diagram (page 6)
Afb. 5 · mm ° kg
3 2 1 123 mm× √h" 4546474849505152 3” 75mm1√××××√××× 1××××√×××× 2√××√××××× 2××√×××××× 3××××××××× 4” 98mm1√×××××√×× 1×××××√××× 2××××√×××× 3√××√××××× 3××√×××××× 5” 124mm1√××××××√× 1××××××√×× 2×××××√××× 3××××√×××× 6” 140mm1√×××××××√ 1×××××××√× 2××××××√×× 3×××××××××

×

Page 7 of the Quickie Argon 2 user manual — mm ° kg
Pagina 7 · klik om te vergroten
Pagina 7
Quickie Argon 2 — mm ° kg diagram (page 7)
Afb. 6 · mm ° kg
h100mm 100mm 46” 45” 44” 43” 42” h = 40” 39” 37” 36” 35” 34”22” (489)6° - 9°A2 A3 A4 A4 A5 A6 A7 A8 B2 B3 B4 B50° - 3° 49” 48” 47” 45” 44” 43” h = 42” 41” 40” 39” 37” 36”24” (540)6° - 9°A2 A3 A4 A4 A5 A6 A6 A7 A7 A8 A9 B2 B3 B4 B50° - 3° 50” 49” 48” 47” 45” 44” h = 43” 42” 41” 39” 38” 37”25” (559)6° - 9°A2 A3 A4 A5 A6 A7 A7 A8 A9 A8 B2 B3 B4 B50° - 3° 52” 50” 49” 48” 47” 46” h = 45” 43” 42” 41” 40” 39”26” (590)6° - 9°A2 A4 A3 A4 A5 A5 A6 A7 A8 A9 B2 B3 B4 B50° - 3°
Page 8 of the Quickie Argon 2 user manual — mm ° kg
Pagina 8 · klik om te vergroten
Pagina 8
Page 8 of the Quickie Argon 2 user manual — mm ° kg
Page 9 of the Quickie Argon 2 user manual — Area of application
Pagina 9 · klik om te vergroten
Pagina 9

Foreword

Use

Wheelchairs are exclusively for a user who is unable to walk or has limited mobility, for their own personal use in- and outdoor.

We are very pleased that you have decided in favour of a high-quality SUNRISE MEDICAL product.

The maximum weight limit (includes the user and any weight of accessories fitted to the wheelchair) is marked on the serial number label, which is affixed to the Axle Tube below the seat.

This Owner’s manual will provide numerous tips and ideas so that your new wheelchair can become a trustworthy and reliable partner in your life.

For Sunrise Medical, it is very important that we have a good relationship with our customers. We like to keep you up-to-date about new and current developments at our company. Keeping close to our customers means: fast service, as little red tape as possible, working closely with customers. When you need replacement parts or accessories, or if you just have a question abour your wheelchair – we are there for you.

Warranty can only be taken on if the product is used under the specified conditions and for the intended purposes. The expected life of the wheelchair is 5 years. Please DO NOT use or fit any 3rd party components to the wheelchair unless they are officially approved by Sunrise Medical.

We want you to be satisfied with our products and service. At Sunrise Medical we are constantly working to develop our products further. For this reason, changes can occur in our palette of products with regard to form, technology, and equipment. Consequently, no claims can be construed from the data or pictures contained in this Owner’s manual.

Area of application

The management system of SUNRISE MEDICAL is certified to EN ISO 9001, ISO 13485 and ISO 14001.

The variety of fitting variants as well as the modular design mean that it can be used by those who cannot walk or have limited mobility because of:

As the manufacturer, SUNRISE MEDICAL, declares that the lightweight wheelchairs conform to the 93/42/EEC / 2007/47/EEC guideline.

  • Paralysis
  • Loss of extremity (leg amputation)
  • Extremity defect deformity
  • Joint contractures/joint injuries
  • Illnesses such as heart and circulation deficiencies, disturbance of equilibrium or cachexia as well as for elderly people who still have strength in the upper body.

Please contact your local, authorised SUNRISE MEDICAL dealer if you have any questions regarding the use, maintenance or safety of your wheelchair.

In case there is no authorised dealer in your area or you have any questions, contact Sunrise Medical either in writing or by telephone.

When considering provision, please also note the body size, weight, physical and psychological constitution, the age of the person, living conditions and environment.

Sunrise Medical Thorns Road Brierley Hill West Midlands DY5 2LD England Phone: 0845 605 66 88 Fax: 0845 605 66 89 www.SunriseMedical.com

Dear Customer,

Page 10 of the Quickie Argon 2 user manual — DANGER!
Pagina 10 · klik om te vergroten
Pagina 10

1.0 General safety notes and driving limits

  • To avoid falls and dangerous situations, you should first practice using your new wheelchair on level ground with good visibility.
  • When getting on or off the wheelchair, do not use the footboards. These should be flipped up beforehand and swung to the outside as far as possible. Always position yourself as close as possible to the place where you wish to sit.
  • Only use your wheelchair properly. For example, avoid travelling against an obstacle without braking (step, kerb edge) or dropping down gaps.
  • The wheel locks are not intended to brake your wheelchair. They are only there to ensure that your wheelchair does not begin rolling unintentionally. When you stop on uneven ground, you should always use the wheel locks to prevent such rolling. Always apply both wheel locks; otherwise, your wheelchair could tip over.
  • Explore the effects of changing the centre of gravity on the behaviour of the wheelchair, for example on inclines, slopes, all gradients, or when overcoming obstacles. Do this with the secure aid of a helper.
  • With extreme settings (e.g. rear wheels in the most forward position) and less than perfect posture, the wheelchair may tip over even on a level surface.
  • Lean your upper body further forward when going up slopes and steps.
  • Lean your upper body further back when going down slopes and steps. Never try to climb and descend a slope diagonally.
  • Avoid using an escalator which may lead to serious injury in the event of a fall.
  • Do not use the wheelchair on slopes > 10°. The Dynamic safe slope is dependant on the chair configuration, the users abilities and the style of riding. As the users abilities and style of riding cannot be pre-determined then the max safe slope cannot be determined. Therefore this must be determined by the user with the assistance of an attendant to prevent tipping. It is strongly recommended that inexperienced users have Ant-tips fitted.
  • It is possible that potholes or uneven ground could cause this wheelchair to tip over, especially when riding uphill or downhill.
  • Do not use your wheelchair on muddy or icy ground. Do not use your wheelchair where pedestrians are not allowed.
  • To avoid hand injuries do not grab in between the spokes or between the rear wheel and wheel lock when driving the wheelchair.
  • In particular when using lightweight metal handrims, fingers will easily become hot when braking from a high speed or on long inclines.
  • Only attempt stairs with the help of an attendant. There is equipment available to help you, e.g. climbing ramps or lifts, please use them. If there is no such equipment available, then the wheelchair must be tipped and pushed, never carried, over the steps (2 helpers). We recommend that users over 100 kg in weight do not use this stairway manoeuvre!
  • In general, any anti-tip tubes fitted must be set beforehand, so that they cannot touch the steps, as otherwise this could lead to a serious tumble. Afterwards the anti-tip tubes must be set back to their correct position.
  • Make sure that the attendant only holds the wheelchair using securely mounted parts (e.g. not on the footrests or the sideguards).
Quickie Argon 2 — 1.0 General safety notes and driving limits diagram (page 10)
Afb. 7 · 1.0 General safety notes and driving limits

The engineering and construction of this wheelchair has been designed to provide maximum safety. International safety standards currently in force have either been fulfilled or exceeded in parts. Nevertheless, users may put themselves at risk by improperly using their wheelchairs. For your own safety, the following rules must be strictly observed. Unprofessional or erroneous changes or adjustments increase the risk of accident. As a wheelchair user, you are also part of the daily traffic on streets and pavements, just like anyone else. We would like to remind you that you are therefore also subject to any and all traffic laws. Be careful during your first ride in this wheelchair. Get to know your wheelchair. Before each use, the following should be checked:

  • Quick-release axles on the rear wheels
  • Velcro on seats and backrests
  • Tyres, tyre pressure and wheel locks.

Before changing any of the adjustments of this wheelchair, it is important to read the corresponding section of the user’s manual. It is possible that potholes or uneven ground could cause this wheelchair to tip over, especially when riding uphill or downhill. When riding over a step or up an incline frontally, the body should be leaning forward.

DANGER!

  • NEVER exceed the maximum load of 140 kg, (100kg with hand bike axle), for driver plus any items carried on the wheelchair. If you exceed the maximum load, this can lead to damage to the chair, or you may fall or tip over, lose control and may lead to serious injury of the user and other people.
  • When it is dark, please wear light clothing or clothing with reflectors, so that you can be seen more easily. Make sure that the reflectors on the side and back of the wheelchair are clearly visible. We would also recommend that you fit an active light..
Page 11 of the Quickie Argon 2 user manual — WARNING !
Pagina 11 · klik om te vergroten
Pagina 11

WARNING !

  • When using the lifting ramp make sure that the antitip tubes fitted are positioned outside the danger area.
  • Secure your wheelchair on uneven ground or when transferring (e.g. into a car) by using the brakes.
  • If and whenever possible, during a journey in a specially fitted vehicle for disabled people, vehicle occupants should use the seats in the vehicle and the appropriate restraint system. This is the only way to ensure that occupants will have the maximum protection if there is an accident. When using safety elements offered by SUNRISE MEDICAL and using a specially designed safety system, lightweight wheelchairs can be used as a seat when being transported in a specially fitted vehicle. (See the Chapter on “Transportation”).
  • Depending on the diameter and setting of the castors, as well as the centre of gravity setting of the wheelchair, the castors may begin to wobble at high speeds. This can lead to the castors being blocked and the wheelchair may tip over. Therefore, please make sure that the castors are adjusted correctly (see the Chapter “Castors”). In particular, do not travel on an incline without brakes, travel at a reduced speed. We recommend that novice users use anti-tip tubes.
  • Anti-tip tubes should prevent the chair tipping over backwards unintentionally. Under no circumstances should they take the place of transit wheels, and be used to transport a person in a wheelchair with the rear wheels removed.
  • When reaching for objects (which are in front of, to the side or behind the wheelchair) make sure that you do not lean too far out of the wheelchair, as if you change the centre of gravity there is a risk of tipping or rolling over. The hanging of additional load (back pack or similar items) onto your chair backposts can affect the rearward stability of your chair, especially when used in combination with recliner backrests. This can cause the chair to tip backwards causing injury.
  • For thigh amputees you must use anti-tip tubes.
  • Before setting off, check that your tyre pressure is correct. For rear wheels it should be at least 3.5 bar ( 350 kPa). The max. pressure is indicated on the tyre. The knee-lever brakes will only work if there is sufficient tyre pressure and if the correct setting has been made (see the Chapter on “Brakes”).
  • If the seat and back sling are damaged, you must replace them immediately.
  • Be careful with fire, in particular with burning cigarettes. Seat and back slings can be set alight.
  • If the wheelchair is subject to direct sunlight for a long period of time, then parts of the wheelchair (e.g. frame, legrests, brakes and sideguard) may become hot (>41°C).
  • Always make sure that the quick-release axles on the rear wheels are set properly and lock in. If the button on the quick-release axle is not pressed in, the rear wheel cannot be removed.
  • The effect of the knee-lever brake as well as the general driving characteristics are dependant on tyre pressure. The wheelchair is significantly lighter and easier to manoeuvre when the rear wheels are pumped up correctly and both wheels have the same pressure.
  • Make sure that your tyres have sufficient tread! Please note that you are subject to any and all traffic laws when driving in public traffic.
  • Always be careful with your fingers when working or adjusting the wheelchair!
  • Settings on the wheelchair should only be carried out by competent persons.

WARNING !

Choking Hazard – This mobility aid uses small parts which under certain circumstances may present a choking hazard to young children.

The products shown and described in this manual may not be exactly the same in every detail as your own model. However, all instructions are still entirely relevant, irrespective of detail differences.

The manufacturer reserves the right to alter without notice any weights, measurements or other technical data shown in this manual. All figures, measurements and capacities shown in this manual are approximate and do not constitute specifications.

We at SUNRISE MEDICAL have been awarded the ISO 9001 Certificate, which affirms the quality of our products at every stage, from R & D to production. This product complies with the standards set forth in EU directives. Optional equipment and accessories are available at extra charge.

Page 12 of the Quickie Argon 2 user manual — CAUTION !
Pagina 12 · klik om te vergroten
Pagina 12

2.0 Handling

3.0 Transporting the chair

  • Getting Into Your Wheelchair On Your Own
  • Push the wheelchair to a wall or a solid piece of furniture.
  • Apply the brakes;
  • The user can lower themselves into the wheelchair;
  • Then position the feet in front of the heel straps (Fig.2.0).

Transporting The Chair Removing the rear wheels will keep the chair as compact as possible. The backrest can be folded down by pulling the cord (1) (see picture 3) located on the backrest (Fig.3.0-3.1).

  • Getting out of your wheelchair on your own
  • Apply the brakes;
  • With one hand on the wheel or side guard, the person should lean forwards slightly, to transfer the body weight to the front edge of the seat and then push up to an upright position with both feet firmly on the floor and one foot behind the other (Fig.2.1).
Quickie Argon 2 — 2.0 Handling diagram (page 12)
Afb. 8 · 2.0 Handling
Quickie Argon 2 — 2.0 Handling diagram (page 12)
Afb. 9 · 2.0 Handling

CAUTION !

When folding the backrest down, please make sure that your fingers do not get caught.

Quickie Argon 2 — CAUTION ! diagram (page 12)
Afb. 10
Quickie Argon 2 — CAUTION ! diagram (page 12)
Afb. 11

4.0 Options

Quick-Release Axles On Rear Wheel The rear wheels are equipped with quick-release axles. The wheels can, therefore, be installed or removed without using tools. To remove a wheel, simply depress the quick-release button on the axle (1) and pull it out (Fig.2.2).

Step Tubes

Quickie Argon 2 — Step Tubes diagram (page 12)
Afb. 12 · Step Tubes

Step Tubes Step tubes are used by attendants to push a wheelchair over an obstacle. Simply step on the tube to push a wheelchair, for example, over a kerb or step, (Fig.4.0).

WARNING!

Sunrise Medical strongly reccommends the use of a step tube on any model where attendant use is the predominant intended use. Damage to the backposts may occur if you constantly use the backpost without a step tube, as a lever to pull back on to tip the wheelchair.

CAUTION !

Hold the quick-release button on the axle depressed when inserting the axle into the frame to mount the rear wheels. Release the button to lock the wheel in place. The quick- release button should snap back to its original position

Quickie Argon 2 — CAUTION ! diagram (page 12)
Afb. 13
Page 13 of the Quickie Argon 2 user manual — CAUTION !
Pagina 13 · klik om te vergroten
Pagina 13

Wheel Locks (Brakes)

Brake Lever Extension The longer lever helps to minimise the effort needed to set the wheel locks. The brake lever extension is screwed to the brakes. By raising this, it can be flipped forward (Fig. 4.3).

Quickie Argon 2 — Wheel Locks (Brakes) diagram (page 13)
Afb. 14 · Wheel Locks (Brakes)
Quickie Argon 2 — Wheel Locks (Brakes) diagram (page 13)
Afb. 15 · Wheel Locks (Brakes)

CAUTION !

Mounting the wheel lock too close towards the wheel will result in a higher effort to operate. This might cause the brake lever extension to break!

Leaning onto the brake lever extension while transferring will cause the lever to break! Splashing water from tyres might cause the wheel lock to malfunction.

CAUTION !

Braking efficiency can be affected by:

CAUTION !

  • Incorrect fitting of the brake assembly.
  • Incorrect adjustment of the assembly.
  • Incorrect tyre pressures.
  • Worn tyre treads.
  • Wet tyres.

Incorrect mounting of the wheel lock will result in a higher effort to operate. This might cause the wheel lock extension lever to break.

Wheel Locks Your wheelchair is equipped with two wheel locks. They are applied directly against the tyres. To engage, press both brake levers forward against the stops. To release the locks, pull the levers back to their original positions.

Compact Brakes Compact brakes are underneath the seat sling and are operated by pulling the brakes towards the rear, in the direction of the tyre. For the brakes to work properly, this must be pulled until it reaches the stops, (Fig.4.4).

The wheel locks have not been designed to be used as brakes for a moving wheelchair. The wheel locks should therefore never be used to brake a moving wheelchair. Always use the hand-rims for braking. Make sure that the gap between the tyres and wheel locks complies with given specifications. To re-adjust, loosen the screw and set the appropriate gap. Then re-tighten the screw (Fig. 4.1 and 4.2).

Quickie Argon 2 — CAUTION ! diagram (page 13)
Afb. 16
Quickie Argon 2 — CAUTION ! diagram (page 13)
Afb. 17

CAUTION !

After each adjustment of the rear wheels, check the wheel lock gap and re-adjust if necessary.

3 mm

Page 14 of the Quickie Argon 2 user manual — CAUTION!
Pagina 14 · klik om te vergroten
Pagina 14

The One-arm Wheel Lock The one arm wheel lock is underneath the seat sling and is operated by pulling the brake lever, which is located on the left or right side, towards the rear, in the direction of the tyre. For the brakes to work properly, this must be pulled until it reaches the stop, (Fig.4.5)

Hand-Bike Axle Adjustment

It is necessary to adjust the hand-bike axle to bias the centre of gravity rearwards. This allows safe use of a hand-bike accessory, (Fig.4.7).

Adjustment To adjust the brake, loose the screws (1) and mount the wheel lock where it will work in a proper way (Fig.4.6).

DANGER!

Using a hand-bike without the hand-bike axle makes the wheelchair unstable and can lead to serious injury of the user and other people.

CAUTION!

Incorrect mounting of the one arm wheel lock can lead to serious injury of the user and other people.

Quickie Argon 2 — CAUTION! diagram (page 14)
Afb. 18
Quickie Argon 2 — CAUTION! diagram (page 14)
Afb. 19
Quickie Argon 2 — CAUTION! diagram (page 14)
Afb. 20

Hand-Bike-Axle

Page 15 of the Quickie Argon 2 user manual — WARNING!
Pagina 15 · klik om te vergroten
Pagina 15

Footplate Adjustment

Footboard

Quickie Argon 2 — Footplate Adjustment diagram (page 15)
Afb. 21 · Footplate Adjustment

WARNING!

There are several footboards available. These can be flipped up to make it easier to transfer to/ from the chair, (Fig.4.11).

  • Attendant: Do not stand on the footboard! Even if the user is sitting in the chair, there is still a risk of tipping over and injury.
  • User: When transferring, do not stand on the footboard, there is a risk of tipping over and injury.

Releasing the screw (1) will allow you to adjust the footrest to correspond to the length of your lower leg and re-attach the footrest. The angle of the footrest may be individually adjusted by loosening screws (2). The side protection (3) on the footrest prevents the feet slipping off accidentally. Make sure that after any adjustment work, all screws are tightened correctly (see the page on torque) (Fig. 4.8 - 4.9).

Angle-Adjustable Footboard The footboard can be flipped up to make it easier to transfer to and from the chair, (Fig.4.12-4.14). It can be adjusted to alter the angle to the ground. Tighten screw (1) on the outside. By loosening the clips (2) the footboard can be moved to three positions both forwards and backwards. By adjusting the set screw (3) the footboard can be changed to a horizontal position. To do this, the footboard must be flipped up. Make sure that after any adjustment work, all screws are tightened correctly (see the page on torque). Ensure that you maintain the minimum gap to the floor of 2.5 cm (Fig.4.15).

Quickie Argon 2 — WARNING! diagram (page 15)
Afb. 22
Quickie Argon 2 — WARNING! diagram (page 15)
Afb. 23

Footplates: The footplates can be flipped up to make it easier to transfer to/from the chair.

Quickie Argon 2 — WARNING! diagram (page 15)
Afb. 24
Quickie Argon 2 — WARNING! diagram (page 15)
Afb. 25
Quickie Argon 2 — WARNING! diagram (page 15)
Afb. 26
Quickie Argon 2 — WARNING! diagram (page 15)
Afb. 27

>2.5cm

Footrest - Aluminium · Adjusting The Footrest · Footrest - Plastic

Page 16 of the Quickie Argon 2 user manual — Castors
Pagina 16 · klik om te vergroten
Pagina 16

Castors

Seat Seat Sling

Castor, Castor Adapter, Castor Fork

Quickie Argon 2 — Castors diagram (page 16)
Afb. 28 · Castors

Remove the screws on the left side of the sling. Adjust the VELCRO® material to increase the tension of the seat sling. Tighten up the screws again.

  • From time to time the wheelchair may veer slightly to the right or left, or the castors may flutter. This may be caused by the following:
  • The forward or reverse wheel motion has not been set properly.
  • The castor angle has not been adjusted properly.
  • Castor and/or rear wheel air pressure is incorrect; wheels do not turn smoothly.

If the screws are difficult to fit back in place, try and locate the holes with a sharp object. Ensure also that the plastic base is in the correct position before the screws are tightened again, (Fig.4.16).

The optimum adjustment of the castors is required for the wheelchair to run in a straight line. Castors should always be adjusted by an authorized dealer. The castor plates must be re-adjusted, and the wheel locks must be checked any time the rear wheel position has been altered.

Seat height Adjusting the Seat Height (Fig.4.17)

To adjust rear seat height, slacken and remove the 4 screws (1) (2 each side), which secures the clamp (2) Adjust the two clamps to the required height and replace the 4 screws. Before tightening the screws, please follow the instructions for setting the toe-in/toe-out to zero (See Fig.4.19-4.20). Tighten the screws to 7 Nm.

To ensure that both forks are set parallel, simply count the teeth visible on both sides. After setting the castor fork, the teeth will guarantee a secure position, allowing an adjustment of 16° in 2° increments. Use the flat side on the front of the castor fork to check for a right-angled position to the ground (Fig. 4.19). The patented design allows the castor fork to be turned, so that it can be reset at right-angles to the ground when the seat angle is changed.

Quickie Argon 2 — Castors diagram (page 16)
Afb. 29 · Castors

Setting the Directional Stability

Release the Allen screws (1) on the underside of the fork. You can then undo the screw (2). You can now turn the black socket (3) left or right. Left – chair pulls to the left Right – chair pulls to the right Then tighten up the screw (2) again. Please set a 90° angle from the fork to the floor. Now tighten up the screw (1) again. (Fig. 4.20).

Quickie Argon 2 — Castors diagram (page 16)
Afb. 30 · Castors
Quickie Argon 2 — Castors diagram (page 16)
Afb. 31 · Castors

Adjusting the Castor · +8 -8

Page 17 of the Quickie Argon 2 user manual — CAUTION !
Pagina 17 · klik om te vergroten
Pagina 17

Wheel alignment

Quickie Argon 2 — Wheel alignment diagram (page 17)
Afb. 32 · Wheel alignment
Quickie Argon 2 — Wheel alignment diagram (page 17)
Afb. 33 · Wheel alignment

Adjusting The Wheel Alignment

Important: To achieve the very best movement, the rear wheels must be adjusted to their optimum position, which means correctly adjusting the wheel alignment. To do this, measure the distance between both wheels front and rear to ensure that they are parallel to one another. The difference between both measurements should not exceed 5 mm. To adjust the wheels to make them parallel, loosen the screws and turn the axle sleeve accordingly. Make sure that after any adjustment work, all screws are tightened correctly (see the page on torque).

Quickie Argon 2 — Wheel alignment diagram (page 17)
Afb. 34 · Wheel alignment

BALL

Argon2 Tracking Adjustment Setting the toe-in/toe-out to zero.

Backrest

Angle-Adjustable Back The backrest angle is adjusted by altering the position of the pin in the backrest mounting. The pin (1) must be completely clicked into place in the hole pattern on both sides, this gives you an angle adjustment of 8.5°. Fit the red plastic pins into the unused holes. To reach a smaller angle increment (3.5°), you open the allen key screw (2) and re-set the screw into the second hole. Please use the relevant torque force (see matrix) to tighten the screw (2). This gives you 12° change in the back angle. Then move the pin (1) in the opposite direction to the next hole, which gives you 12° - 8°= 3.5° change. (Fig. 4.25)

NOTE: A wheelchair with 0° camber cylinders cannot have toe-in or toe-out. This setting is necessary only with 3°, 6° and 9° camber cylinders. The term "toe-in or toe-out" defines how well the rear wheels of the chair are aligned in relation to the ground. This determines how well the chair will run. Normal resistance or rolling resistance is present when toe-in is set to zero.

To set toe-in/toe-out to zero: loosen the Allen screws (1) (1 on each side), which secure the angle tube clamp. Check the ball in the horizontal (2) plane and turn the angle tube (3) until the ball is in the centre. Toe-in is now zero. Before tightening the screws (1), check that the camber tube is centred left-to-right. The gap should be the same on both sides, or there should be no gap at all. Tighten the screws to 7 Nm. (Fig. 4.21-4.23).

To reduce the play in the backrest, the nut (1) can be released, then the optimal position can be set using the set screw (2). Then re-tighten the nut (1). (Fig. 4.26).

CAUTION !

The screws must be re-tightened. Otherwise the angle adjustment will be lost.

Adjusting the Rear Wheelbase Width: The rear wheelbase is defined as the distance between the upper side of the rear wheels and the backrest tubes, and is represented by factory setting (1.25 cm). This has to be increased if a larger gap between the tyres and the optional height-adjustable armrests has to be created (Fig. 4.24).

Folding Backrest Release the backrest by pulling the cord. At the same time, push it forward to fold it down. To return the backrest to its original position, this must be pulled back as far as possible, until it locks into place on both sides.

NOTE: When adjusting the rear wheelbase, adjust first one wheel then the other. If both sides are loosened at the same time, this will alter the toe-in/toe-out adjustment. To adjust the rear wheelbase, the parts of the camber (4) move telescopically into or out of the camber tube (5), and lock into place when they reach the end. Loosen screw (6) (located closest to the camber tube) on the left side of the chair. Move the quick-release axle inwards or outwards to achieve the desired wheelbase. Tighten the screws to 7 Nm. Repeat this procedure on the right side of the chair and adjust the gap so that it is the same amount as on the left side.

CAUTION !

When folding the backrest down, please make sure that your fingers do not get caught.

Quickie Argon 2 — CAUTION ! diagram (page 17)
Afb. 35
Quickie Argon 2 — CAUTION ! diagram (page 17)
Afb. 36
Page 18 of the Quickie Argon 2 user manual — Sideguard
Pagina 18 · klik om te vergroten
Pagina 18

Adjustable Back Sling The adjustable back sling can be adjusted for tension by using several straps. The back sling upholstery can be accessed from the inside via an opening and can be padded to suit individual tastes (Fig. 4.27).

Armrest Receiver Attachment (Fig.4.29-4.32).

Adjusting Armrest Receiver Fit To tighten or loosen the fit of the outer armpost in the receiver: 1. Loosen the four receiver adjustment bolts (9) on the sides of the receiver. 2. With the armrest in the receiver (7), squeeze the receiver to achieve the desired fit. 3. Tighten the four bolts (9). (144 in-lbs, 16.3 Nm)

Height-Adjustable Backrest The backrest may be set to various back heights, in 2.5 cm steps. The adjustment ranges are 25- 30 cm, 30- 35 cm, 35- 40 cm and 40- 45 cm. Release the screws (1+2) and set the backrest to the desired height. Tighten up the screws again (see the page on torque). (Fig. 4.28).

Position Adjustment 1. Loosen the two clamp bolts (10) until clamp is loose. 2. Slide armrest receiver to desired position. 3. Tighten

Quickie Argon 2 — Sideguard diagram (page 18)
Afb. 37 · Sideguard
Quickie Argon 2 — Sideguard diagram (page 18)
Afb. 38 · Sideguard

Fig.4.29 - 4.30 Parts key

1. Outer armpost 2. Height Release Lever 3. Release lever 4. Armrest pad 5. Transfer bar 6. Side panel 7. Receiver 8. Clamp 9. Receiver adjustment bolts 10. Clamp bolts

Sideguard

Quickie Argon 2 — Sideguard diagram (page 18)
Afb. 39 · Sideguard
Quickie Argon 2 — Sideguard diagram (page 18)
Afb. 40 · Sideguard

Single Post Height-Adjustable Armrests (Fig.4.29-4.32).

1. Installation a. Slide the outer armpost into the receiver mounted to

the wheelchair frame. b. The armrest will automatically lock into place.

2. Height Adjustment a. Rotate height release lever (2) to second stop. b. Slide armrest pad up or down to desired height. c. Return lever to locked position against arm post. d. Push arm pad (4) until upper arm post locks firmly into
Quickie Argon 2 — Sideguard diagram (page 18)
Afb. 41 · Sideguard
Quickie Argon 2 — Sideguard diagram (page 18)
Afb. 42 · Sideguard

place.

3. Removing Armrest a. Pull lever 3 and lift entire arm.
4. Replacing Armrest a. Slide armrest back into receiver until arm latches in

place.

Page 19 of the Quickie Argon 2 user manual — WARNING!
Pagina 19 · klik om te vergroten
Pagina 19

Push Handles

Sideguards

Tool Height Adjustable Armrest

These handles are secured with pins to prevent them from sliding out unintentionally. Opening the quick-release lever (1) makes it possible to adjust the height of the push handles (2) to meet your individual needs. As you move the lever, you will hear a locking mechanism; you can now easily position the push handle as desired. The nut on the tension lever determines how tightly the push handles are clamped into place. If the nut is loose after adjusting the tension lever, the push handle will also be too loose. Turn the push handle from side to side before use to make sure that it is clamped securely enough into place. After adjusting the handle height, always clamp the tension lever (1) securely into place. If the lever is not secure, injuries could result when ascending stairs. (Fig. 4.33).

Installation: Slide the arm post into the receiver, located on the wheelchair frame, until it stops

Height Adjustment: Slide the arm rest post out of the receiver. Adjust the position of the hight adjustment bracket (1) by removing the screw (2) and moving it to the desired posiion. Re-fit the screw and tighten it. Slide the arm rest post back into the receiver, (Fig.4.32.1).

Armpad Position: The armpad position can be adjusted by relesing the screws (3), then moving the arm pad to the desired position. Re-tighten the screws, (Fig.4.32.1).

Adjusting Armrest Receiver The tightness of the armrest receiver can be adjusted (tightened /loosened) by means of the 2 screws (1) - (Fig.4.32.2).

If the push handles are not in use, they can be folded down depressing the button (2). When they are needed again, simply flip them back up until they click into place. (Fig. 4.34).

Quickie Argon 2 — Push Handles diagram (page 19)
Afb. 43 · Push Handles
Quickie Argon 2 — Push Handles diagram (page 19)
Afb. 44 · Push Handles

Tubular Armrest, Tool Height Adjustable, Swing Away, Removable, (Fig.5.22). For easier transfer lift the armrest slightly and swing it away or detach it by pulling it up. The height can be adju- sted by the position of the screw G.

WARNING!

Sideguards, and the armrests are not designed to be used to lift or carry the wheelchair.

Quickie Argon 2 — WARNING! diagram (page 19)
Afb. 45
Quickie Argon 2 — WARNING! diagram (page 19)
Afb. 46
Quickie Argon 2 — WARNING! diagram (page 19)
Afb. 47

Height-Adjustable Push Handles · Fold-Down Push Handles

Page 20 of the Quickie Argon 2 user manual — DANGER !
Pagina 20 · klik om te vergroten
Pagina 20

Anti-Tip Tubes

Active Anti Tip/Flip Up

The active Anti tip is mounted on the left or right side of the axle tube. By pushing it towards the axle tube, it can be flipped downwards for operation, (Fig.4.36).

WARNING !

Sunrise Medical recommends anti-tip tubes for all chairs. When fitting anti-tip tubes, use a torque of 7 Nm.

WARNING!

1. Slotting The Anti-Tip Tubes Into The Clamp: a. Press the rear button on the anti-tip tube on the anti-tip tube adapter, so that both release pins are drawn inwards. b. Slot the anti-tip tubes (1) into the anti-tip tube adapter. c. Turn the anti-tip tubes downwards until the release pin locks into the clamp. d. Fit the second anti-tip tube in the same way.

Make sure that the anti tip will lock in the final position. An unlocked active anti tip can lead to serious injury of the user.

2. Adjusting The Anti-Tip Tubes To achieve the correct ground clearance of approx. 1" to 2" (2.5 cm to 5.0 cm), the anti-tip tubes must be raised or lowered. Press the anti-tip tube release button, so that both release pins are drawn inwards. Move the inner tube up or down to slot into the height holes provided. Release the button. Fit the second anti-tip wheel in the same way. Both wheels should be at the same height. (Fig. 4.35).
Quickie Argon 2 — WARNING! diagram (page 20)
Afb. 48

DANGER !

Sunrise Medical Recommends Use Of Anti-Tip Tubes: If the anti-tip tubes are not fitted, or have been fitted incorrectly, there is a risk of tipping over and of injury.

Active Anti Tip For Sport

To remove the active anti tip for sport, press the button of the quick release pin and pull it out. Now pull out the tube from the anti tip receiver, (4.37-4.38).

Quickie Argon 2 — DANGER ! diagram (page 20)
Afb. 49
Quickie Argon 2 — DANGER ! diagram (page 20)
Afb. 50
Quickie Argon 2 — DANGER ! diagram (page 20)
Afb. 51
Page 21 of the Quickie Argon 2 user manual — Travel Wheels
Pagina 21 · klik om te vergroten
Pagina 21

Crutch holder

Anteria Lateral Support (Lap belt)

Crutch Holder (Fig.4.39) This device permits crutches to be transported directly on the wheelchair. It has a Velcro loop to fasten crutches or other aids.

DANGER !

  • Before using your wheelchair ensure the lap belt is worn.
  • The lap belt must be checked on a daily
  • basis to ensure it is free from any obstruction or adverse wear.
  • Always make sure that the lap belt is correctly secured and adjusted prior to use. If the strap is too loose it could cause the user to slip down and risk suffocation or cause serious injury.

CAUTION!

Never try to use or even remove the crutches or other aids while moving.

The lap belt is fitted to the wheelchair as shown in the illustrations. The seat belt comprises 2 halves. They are fitted using the existing seat stay retaining bolt fitted through the eyelet on the belt. The belt is routed under the rear of the side panel. (Fig. 4.41)

Quickie Argon 2 — CAUTION! diagram (page 21)
Afb. 52

Adjust the belt position so buckles are in the centre of the seat. (Fig. 4.42)

Travel Wheels

Quickie Argon 2 — Travel Wheels diagram (page 21)
Afb. 53 · Travel Wheels
Quickie Argon 2 — Travel Wheels diagram (page 21)
Afb. 54 · Travel Wheels

Travel Wheels (Fig.4.40) Travel wheels should be used wherever your wheelchair would be too wide if the rear wheels were used (e.g., in airplanes, buses, etc.). After the rear wheels have been removed with the aid of the quick-release axles, the transit wheels can immediately be used to continue riding. The transit wheels are mounted so that they are approx. 3 centi meters above the ground when not in use. They are thus out of the way when riding, transporting, or when tipping to pass over obstacles (e.g., kerbs, steps, etc.).

Quickie Argon 2 — Travel Wheels diagram (page 21)
Afb. 55 · Travel Wheels

Adjust Lap Belt To Suit The User’s Needs As Follows:

To reduce the belt

To increase the belt length

Quickie Argon 2 — Travel Wheels diagram (page 21)
Afb. 56 · Travel Wheels
Quickie Argon 2 — Travel Wheels diagram (page 21)
Afb. 57 · Travel Wheels
Quickie Argon 2 — Travel Wheels diagram (page 21)
Afb. 58 · Travel Wheels
Quickie Argon 2 — Travel Wheels diagram (page 21)
Afb. 59 · Travel Wheels

Feed free belt back through male buckle and slide adjusters. Ensure belt is not looped at male buckle.

Feed free belt through slide adjusters and male buckle to provide more belt length.

When fastened check space between the lap belt and user. When correctly adjusted it should not be possible to insert more than the flat of the hand between the lap belt and the user. (Fig. 4.43 overleaf).

length

Page 22 of the Quickie Argon 2 user manual — 6.0 Maintenance and care
Pagina 22 · klik om te vergroten
Pagina 22

Anteria Lateral Support (Lap belt)

Maintenance: Check lap belt, and securing components, at regular intervals for any sign of frays or damage. Replace if necessary.

The lap belt should be fixed so that the belt sits at an angle of 45 degrees across the users pelvis. The user should be upright and be as far back as possible in the seat when correctly adjusted. The lap belt should not allow the user to slip down in the seat. (Fig. 4.44)

WARNING

The lap belt should be adjusted to suit the end user as detailed above. Sunrise Medical recommend that the length and fit of the belt be checked on a regular basis to reduce the risk of the end user inadvertently re-adjusting the belt to an excessive length.

Quickie Argon 2 — WARNING diagram (page 22)
Afb. 60
Quickie Argon 2 — WARNING diagram (page 22)
Afb. 61

5.0 Tyres and Mounting

Solid rubber tyres are standard. With pneumatic tyres always make sure that the tyres have the correct air pressure, as otherwise the performance of the wheelchair may be affected. If the tyre pressure is too low, rolling resistance will increase, requiring more effort to move the chair forward. Low tyre pressure also has a negative impact on manoeuvrability. If the tyre pressure is too high, the tyre could burst. The correct pressure for a given tyre is printed on the surface of the tyre itself.

Quickie Argon 2 — 5.0 Tyres and Mounting diagram (page 22)
Afb. 62 · 5.0 Tyres and Mounting
Quickie Argon 2 — 5.0 Tyres and Mounting diagram (page 22)
Afb. 63 · 5.0 Tyres and Mounting

Tyres are mounted the same way as an ordinary bicycle tyre. Before installing a new inner tube, you should always make sure that the base of the rim and the interior of the tyre are free of foreign objects. Check the pressure after mounting or repairing a tyre. It is critical to your safety and to the wheelchair’s performance that regulation air pressure be maintained and that tyres be in good condition.

To fasten buckle: Firmly push male buckle into female buckle.

To release belt: Press exposed sides of male buckle and push towards centre whilst gently pulling apart.

WARNING !

  • If in doubt about the use and operation of the lap belt then ask your healthcare professional, wheelchair dealer, carer or attendant for assistance.
  • The lap belt must only be fitted by an approved Sunrise Medical dealer / agent.
  • The lap belt should only be adjusted by a professional, or a Sunrise Medical approved dealer / agent.
  • The lap belt must be checked on a daily basis to ensure it is adjusted correctly and free from any obstruction or adverse wear.
  • Sunrise Medical does not encourage the transportation of any person in a vehicle using this lap belt as a method of restraint.

6.0 Maintenance and care

  • Check the tyre pressure every 4 weeks. Check all tyres for wear and damage.
  • Check the brakes approximately every 4 weeks to make sure that they are working properly and are easy to use.
  • Change tyres as you would an ordinary bicycle tyre.
  • All of the joints that are critical to using your wheelchair safely are self-locking nuts. Please check every three months to make sure that all bolts are secure (see the section on torque). Safety nuts should only be used once and should be replaced after use.
  • Please use only mild household cleansers when your wheelchair is dirty. Use only soap and water when cleaning the seat upholstery.

Please see Sunrise Medical transit booklet for further advice on transportation.

Page 23 of the Quickie Argon 2 user manual — 7.0 Disposal / Recycling of materials
Pagina 23 · klik om te vergroten
Pagina 23

Maintenance and care

Particular regulations with regard to disposal or recycling may be in force locally and these must be taken into account when performing disposal. (This can include the cleaning or decontamination of the wheelchair prior to disposal).

  • If your wheelchair should ever get wet, please dry it afterwards.
  • A small amount of sewing-machine oil should be applied to quick-release axles approximately every 8 weeks. Depending on the frequency and type of use, we recommend taking your wheelchair to your authorised dealer every 6 months to have it inspected by trained personnel.
AluminiumCastor forks, wheels, sideguards for the chassis, armrest frame, footrest, push handles

Steel: Fixing points, quick-release axle Plastic: Handles, tube stoppers, castors, footplates, armpads and 12” wheel/tyre Packaging: Plastic bags made of soft polyethylene, cardboard Upholstery: Woven polyester with PVC coatings and expanded combustion modified foam. Disposal or recycling should be carried out by a disposal company or at a public disposal point. You can also return your wheelchair to your dealer for disposal.

CAUTION !

Sand and sea water (or salt in the winter) can damage the bearings of the front and rear wheels. Clean the wheelchair thoroughly after exposure.

  • The following parts can be removed and sent back to the manufacturer/dealer for repair:
  • Rear wheels
  • Armrest
  • Footrest holder
  • Anti-Tip tubes

These components are available as spare parts. For further information, please see the spare parts catalogue.

Hygiene measures when being re-used: Prior to the wheelchair being re-used, it must be carefully prepared. All surfaces which come into contact with the user must be treated with a disinfection spray.

8.0 Trouble-shooting

To do this, you must use a disinfectant from the DGHM list, e.g. Antifect Liquid (Schülke & Mayr) for rapid alcohol- based disinfection for medical products and medical devices, which must be disinfected quickly. Please take into account the manufacturer's instructions for the disinfectant you are using.

  • Wheelchair pulls to one side
  • Check tyre pressure
  • Check to make sure wheel turns easily (bearings, axle)
  • Check the castor angle
  • Check to make sure both castors are making proper contact with the ground

In general, a complete disinfection cannot be guaranteed on seams. We therefore recommend that you dispose of seat and back slings to avoid microbacterial contamination with active agents according to § 6 infection protection law.

  • Castors begin to wobble
  • Check the castor angle
  • Check to make sure all bolts are secure; tighten if necessary (see the section on torque)
  • Check to make sure both castors are making proper contact with the ground
  • Wheelchair squeaks and rattles
  • Check to make sure all bolts are secure; tighten if necessary (see the section on torque)
  • Apply small amount of lubrication to spots where movable parts come into contact with one another
  • Wheelchair begins to wobble
  • Check angle at which castors are set
  • Check tyre pressure
  • Check to see if rear wheels are adjusted differently

7.0 Disposal / Recycling of materials

If the wheelchair has been made available to you free of charge, then it does not belong to you. If it is no longer required, then follow the instructions to return it as given by the organisation that made the wheelchair available to you. In the following section, there is a description of the materials used on the wheelchair, in view of the disposal or recycling of the wheelchair and its packaging.

Page 24 of the Quickie Argon 2 user manual — DANGER !
Pagina 24 · klik om te vergroten
Pagina 24

9.0 Transportability

  • The tie-down restraints should be fitted to the main frame of the wheelchair as indicated in the diagram on the following page, and not to any attachments or accessories, e.g. not around the spokes of wheels, brakes or footrests.
  • The tie–down restraints should be attached as close as possible at an angle of 45 degrees and tightened securely in accordance with the manufacturer’s instructions.
  • Alterations or substitutions must not be made to the wheelchair securement points or to structural and frame or components without consulting the manufacturer. Failure to do so will invalidate the ability of a Sunrise Medical wheelchair to be transported within a vehicle.
  • Both pelvic and upper torso restraint belts must be used to restrain the occupant to reduce the possibility of head and chest impacts with the vehicle components and serious risk of injury to the user and other vehicle occupants. (Fig B) The upper torso restraint belt should be mounted to the vehicle “B” pillar - failure to do so will increase the risk of serious abdominal injuries to the user.
  • A head restraint suitable for transportation (see label on headrest) must be fitted and suitably positioned at all times during transportation.
  • Postural supports (lap straps, lap belts) should not be used or relied on for occupant restraint in a moving vehicle unless they are labelled as meeting the requirements specified in ISO 7176-19:2001 or SAE J2249.
  • The safety of the user during transportation depends upon the diligence of the person securing the tie-down restraints and they should have received appropriate instructions and/or training in their use.
  • Wherever possible remove and stow safely away from the wheelchair all auxiliary equipment, for example:
  • Crutches, Loose cushions and Tray Tables.
  • Articulating/elevating leg rest should not be used in the elevated position when the wheelchair and user are being transported and the wheelchair is restrained using Wheelchair Transport and Occupant Restraints.
  • Reclining backrests should be returned to an upright position.
  • The manual brakes must be firmly applied.
  • Restraints should be mounted to the vehicle “B” pillar and should not be held away from the body by wheelchair components such as armrest or wheels.

DANGER !

There is a risk of serious injury or death if this if this advice is ignored!

Transportation Of Your Wheelchair Within A Vehicle. A wheelchair secured in a vehicle will not provide the equivalent level of safety and security as a vehicle seating system. It is always recommended that the user transfers to the vehicle seating. It is recognised that this is not always practical for the user to be transferred and in these circumstances, where the user must be transported whilst in the wheelchair, the following advice must be followed:

DANGER !

  • Confirm that your chair is crashtest suitable (see nameplate or crashtest bracket at the rear of the chair (Fig.I)
  • Confirm that the vehicle is suitably equipped to transport a passenger in a wheelchair, and ensure the method of access/egress is suitable for your wheelchair type. The vehicle should have the floor strength to take the combined weight of the user, the wheel chair and accessories.
  • Sufficient space should be available around the wheelchair to enable clear access to attach, tighten and release the wheelchair and occupant tie down restraints and safety belts.
  • The occupied wheelchair must be located in a forward facing position and secured by the wheelchair tie down and occupant restraint straps (WTORS tie downs meeting the requirements of ISO 10542 or SAE J2249) in accordance with the WTORS manufacturer’s instructions.
  • The wheelchair’s use in other positions within a vehicle has not been tested e.g. transportation in a side facing position must not be carried out under any circumstances (Fig. A).
  • The wheelchair should be secured by a Tie Down Restraint system, conforming to ISO 10542 or SAE J2249 with non-adjustable front straps and adjustable rear straps, which typically use Karabiner clips/S hooks and tongue and buckle fittings. These restraints generally comprise of 4 individual straps that are attached to each corner of the wheelchair.
Quickie Argon 2 — DANGER ! diagram (page 24)
Afb. 64
Quickie Argon 2 — DANGER ! diagram (page 24)
Afb. 65

Fig.A

Fig.B

Page 25 of the Quickie Argon 2 user manual — PREFERED
Pagina 25 · klik om te vergroten
Pagina 25

Transportability

Occupant Restraints Instruction:

When the user being transported is a child, less than 22Kg mass and the vehicle involved has less than eight (8) seated passengers it is recommended that they be transferred to an UNCE Regulation 44 compliant child restraint system (CRS). This type of restraint system provides a more effective occupant restraint system than the conventional 3 point occupant restraint system and some CRS systems also include additional postural supports to assist in maintaining the position of the child when seated. Parents or care providers may consider the option, in some circumstances, for their child is to remain in their wheelchair whilst in transport due to the level of posture control and comfort provided by the set up in the wheelchair. We would recommend in such circumstances that a risk assessment be carried out by your healthcare professional and relevant competent persons.

1. The pelvic restraint belt must be worn low across the front of the pelvis so that the angle of the pelvic belt is within the preferred zone of 30 to 75 degrees to the horizontal. A steeper (greater) angle within the preferred zone is desirable i.e. closer to, but never exceeding 75degrees. (Fig C)
2. The upper torso restraint belt must fit over the shoulder and across the chest as illustrated Fig d and e Restraint belts must be adjusted as tightly as possible consistent with user comfort. Restraint belt webbing must not be twisted when in use. The upper torso restraint belt must fit over the shoulder and across the shoulder as illustrated in Fig D and E.
3. The attachment points to the chair are the inner front side frame just above the castor, and the rear side frame. The straps are fitted around the side frames at the intersection of the horizontal and vertical frame tubes. (See Figs G-H-I)

Positioning Of Wheelchair Tie Down Restraints On Wheelchair.

1. Location of the front and rear tie down labels (Fig.G - H).
4. The tie down symbol (Fig F) on the wheelchair frame indicates the position of the wheelchair restraint straps. The straps are then tensioned after the front straps have been fitted to secure the wheelchair.
2. Position of the front, (Fig.I) and rear, (Fig.J), wheelchair tie down restraint and the tie down label.
3. Side view of tie down straps, (Fig.K).
Quickie Argon 2 — Transportability diagram (page 25)
Afb. 66 · Transportability

Fig.C

Quickie Argon 2 — Transportability diagram (page 25)
Afb. 67 · Transportability

Fig.F

Fig.I

Quickie Argon 2 — Transportability diagram (page 25)
Afb. 68 · Transportability

PREFERED

ZONE

Quickie Argon 2 — PREFERED diagram (page 25)
Afb. 69

Fig.D

Quickie Argon 2 — PREFERED diagram (page 25)
Afb. 70

Fig.G

Quickie Argon 2 — PREFERED diagram (page 25)
Afb. 71

Fig.J

Fig.E

Quickie Argon 2 — PREFERED diagram (page 25)
Afb. 72

Fig.K

Quickie Argon 2 — PREFERED diagram (page 25)
Afb. 73

Fig.H

Quickie Argon 2 — PREFERED diagram (page 25)
Afb. 74

Minimum User Weight

Page 26 of the Quickie Argon 2 user manual — SAMPLE
Pagina 26 · klik om te vergroten
Pagina 26

10.0 Nameplate

Due to our policy of continuous improvement in the design of our wheelchairs, product specifications may vary slightly from the examples illustrated. All weight/ dimensions and performance data are approximate and provided solely for guidance. Sunrise Medical complies with the EU Medical Devices Directive 93/42/EEC

Nameplate The nameplate is located on either the cross-tube assembly or the transverse frame tube, as well as on a label in the owner’s manual. The nameplate indicates the exact model designation and other technical specifications. Please provide the following pieces of information whenever you have to order replacement parts or to file a claim:

All wheelchairs must be used in accordance with the manufacturer’s guidelines.

Sunrise Medical GmbH & Co.KG Kahlbachring 2-4 69254 Malsch/Heidelberg Germany Tel.: +49 (0) 7253/980-400 Fax: +49 (0) 7253/980-111 www.sunrisemedical.com

SAMPLE

Quickie Argon 2 — SAMPLE diagram (page 26)
Afb. 75

RubiX2 Argon 2

Product Name/SKU Number.

Maximum safe slope with anti-tips fitted, Depends on wheelchair setting, posture and physical capabilities of the user.

Seat Width.

Depth Maximum.

Load Maximum.

CE Mark.

User‘s Guide.

Crash Tested.

Date of Manufacture.

Serial Number.

Show 5 more labels / short text on this page
Argon2 XXXXXX · RubiX2 · Argon2 · Manufacturer Symbol · Argon2 XXXXXX
Page 27 of the Quickie Argon 2 user manual — 11.0 Guarantee
Pagina 27 · klik om te vergroten
Pagina 27

11.0 Guarantee

Guarantee THIS DOES NOT AFFECT YOUR LEGAL RIGHTS IN ANY WAY.

1. Repair or replacement is carried out by the authorised Sunrise Medical dealer.
2. To fulfil the guarantee conditions, should servicing need to be carried out on your wheelchair under this agreement, contact the designated Sunrise Medical authorised dealer immediately, with precise details on the type of difficulty. Should you be using the wheelchair outside the area covered by the designated Sunrise Medical authorised dealer, the work will be carried out under "guarantee conditions" by another dealer as designated by the manufacturer.
3. Should a part or parts of the wheelchair require repair or replacement within 24 months (5 years for frame and crossbrace) after transfer of ownership to the original purchaser, and provided that this person is still the owner of the wheelchair as a result of a specific manufacturing or material defect, the part or parts will be repaired or replaced free of charge, if the wheelchair is returned to the authorised Sunrise Medical dealer.
4. The guarantee also covers all repaired or replaced parts for the remaining period of the guarantee for the wheelchair.
5. For spare parts which are fitted after the start of the original guarantee, we give a further 24-month guarantee.
6. Consumable parts are normally excluded from the guarantee, except in the case that premature wear of the part is the direct result of a manufacturing fault. These parts include, amongst others, upholstery, tyres, inner tubes and similar parts.
7. The guarantee conditions above cover all product parts for models which were purchased at full sales price.
8. Normally we do not accept responsibility if a repair or replacement of the wheelchair is required for one of the following reasons:

a) The product or part has not been maintained or serviced in accordance with the manufacturer's recommendations as shown in the User Instructions and/or the Service Instructions. Accessories have been used which are not specified as original accessories.

b) The wheelchair or a part of the wheelchair was damaged through neglect, accident or improper use.

c) Alterations to the wheelchair or parts, which are not in accordance with the manufacturer's specifications or the carrying out of repairs before informing the authorised dealer.

Guarantee Conditions

Page 28 of the Quickie Argon 2 user manual — 13.0 Torque
Pagina 28 · klik om te vergroten
Pagina 28

12.0 Technical Data

Overall Width: With standard 25" wheels, including handrims with 3° camber: SW + 26 cm Maximum Transported Weight: Less Than 10.0kg Overall Length: 91 cm with SD 48 cm Overall Height: 112 cm with BH 45 cm Weight In Kg: from 9.0 kg

Maximum Load: Argon2 = 140 kg = 125 kg with lightweight wheel. = 100 kg with Proton wheel. = 100 kg with Handbike axle.

Seat heights: The choice of frames, forks and castors, as well as the rear wheel size (24", 25") determines the seat heights which can be achieved.

  • The Wheelchair Conforms To The Following Standards: a) Requirements and tests for static strength, impact resistance and fatigue strength (ISO 7176-8) Yes
  • b) Drive and control systems for power wheelchairs, requirements and test (ISO 7176-14) n.a.
  • c) Environmental test in accordance with ISO 7176-9 n.a.
  • d) Flammability resistance of upholstered parts in accordance with ISO 7176-16 (EN 1021-1/2) Yes

13.0 Torque

Quickie Argon 2 — 13.0 Torque diagram (page 28)
Afb. 76 · 13.0 Torque
Quickie Argon 2 — 13.0 Torque diagram (page 28)
Afb. 77 · 13.0 Torque
Quickie Argon 2 — 13.0 Torque diagram (page 28)
Afb. 78 · 13.0 Torque
Quickie Argon 2 — 13.0 Torque diagram (page 28)
Afb. 79 · 13.0 Torque
Quickie Argon 2 — 13.0 Torque diagram (page 28)
Afb. 80 · 13.0 Torque

Torque.

Show 9 more labels / short text on this page
5Nm · 7Nm · 7Nm · 7Nm 7Nm 7Nm · 5Nm · 5Nm · 25Nm · 5Nm · 5Nm
Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Quickie Argon 2

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Quickie Argon 2

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Quickie Argon 2 handleiding-pdf

72 pagina's·1.7 MB·Rolstoel·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…