M5 = 5.0 Nm. M6 = 7.0 Nm. M8 = 10.0 Nm. Nm




Some of the screws used during manufacturing are coated with thread-locking fluid (blue dot on the thread) and can only be adjusted up to 3 times before they need to be replaced by new thread-locking screws. Alternatively, the screws can be re-mounted using Loctite™ 243 threadlocker.
Certaines vis utilisées pour la fabrication sont enduites de frein-filet (point bleu sur le filetage) ; elles ne peuvent être ajustées que 3 fois, après quoi il convient de les remplacer par de nouvelles vis à frein-filet. Les vis peuvent également être réutilisées avec du frein-filet Loctite™ 243.
Sommige schroeven die tijdens de fabricage worden gebruikt, zijn voorzien van een schroefdraadborgingsmiddel (blauwe stip op de draad) en kunnen slechts drie keer worden versteld voordat ze vervangen moeten worden door nieuwe schroeven met schroefdraadborgingsmiddel. Eventueel kunnen de schroeven opnieuw worden gebruikt waarbij het schroefdraadborgingsmiddel Loctite™ 243 wordt gebruikt.

Use
Wheelchairs are exclusively for children and adults who are unable to walk or has limited mobility, for their own personal use, when self-propelling and being moved by a third party (pushed by attendant) within the home and outdoors.
We are very pleased that you have decided in favour of a high-quality SUNRISE MEDICAL product.
This Owner’s manual will provide numerous tips and ideas so that your new wheelchair can become a trustworthy and reliable partner in your life.
The maximum weight limit (includes both the user and any weight of accessories fitted to the wheelchair) is marked on the serial number label, which is affixed to the cross-brace or the stabilising bar under the seat.
Maintaining close ties to our customers means a lot to us at Sunrise Medical. We like to keep you up-to-date about new and current developments at our company. Keeping close to our customers means: fast service, as little red tape as possible, working closely with customers. When you need replacement parts or accessories, or if you just have a question about your wheelchair – we are there for you.
Warranty can only be issued if the product is used under the specified conditions and for the intended purpose. The expected life of the wheelchair is 5 years. NO NON-STANDARD PARTS are to be fitted, other than those officially approved by Sunrise Medical.
We want you to be satisfied with our products and service. At Sunrise Medical we are constantly working to develop our products further. For this reason, changes can occur in our palette of products with regard to form, technology, and equipment. Consequently, no claims can be construed from the data or pictures contained in this owner’s manual.
The variety of options as well as the modular design means that it can be used by those who cannot walk or have limited mobility because of:
The management system of SUNRISE MEDICAL is certified to DIN EN ISO 9001, ISO 13485 and ISO 14001.
As the manufacturer, SUNRISE MEDICAL, declares that the lightweight wheelchairs
conform to the 93/42/EEC 2007/47/EEC guideline.
Please contact your local, authorised SUNRISE MEDICAL dealer if you have any questions regarding the use, maintenance or safety of your wheelchair.
When considering provision, please also note the body size, weight, physical and psychological constitution, the age of the person, living conditions and environment.
In case there is no authorised dealer in your area, or you have any questions, contact Sunrise Medical either in writing or by telephone.
Sunrise Medical Thorns Road Brierley Hill West Midlands DY5 2LD England Phone: 0845 605 66 88 Fax: 0845 605 66 89 www.SunriseMedical.co.uk
Dear Customer,



Before changing any of the adjustments of this wheelchair, it is important to read the corresponding section of the user’s manual.
It is possible that potholes or uneven ground could cause this wheelchair to tip over, especially when riding uphill or downhill. When riding over a step or up an incline frontally, the body should be leaning forward.
The engineering and construction of this wheelchair has been designed to provide maximum safety. International safety standards currently in force have either been fulfilled or exceeded in parts. Nevertheless, users may put themselves at risk by improperly using their wheelchairs. For your own safety, the following rules must be strictly observed.
Unprofessional or erroneous changes or adjustments increase the risk of accident. As a wheelchair user, you are also part of the daily traffic on streets and pavements, just like anyone else. We would like to remind you that you are therefore also subject to any and all traffic laws. Be careful during your first ride in this wheelchair. Get to know your wheelchair.
Fig. A



Lifetime • The expected lifetime of this product is 5 years.
CHOKING HAZARD – This mobility aid uses small parts which under certain circumstances may present a choking hazard to young children.

5. The wheelchair should be secured by a Tie Down Restraint system, conforming to ISO 10542 or SAE J2249 with non-adjustable front straps and adjustable rear straps, which typically use Karabiner clips/S hooks and tongue and buckle fittings. These restraints generally comprise of 4 individual straps that are attached to each corner of the wheelchair. 6. The tie-down restraints should be fitted to the main frame of the wheelchair as indicated in the diagram on the following page, and not to any attachments or accessories, e.g. not around the spokes of wheels, wheel locks or footrests. 7. The tie–down restraints should be attached as close as possible at an angle of 45 degrees and tightened securely in accordance with the manufacturer’s instructions. 8. Alterations or substitutions must not be made to the wheelchair securing points or to structural and frame or components without consulting the manufacturer. Failure to do so will invalidate the ability of a Sunrise Medical wheelchair to be transported within a vehicle. 9. Both pelvic and upper torso restraint belts must be used to restrain the occupant to reduce the possibility of head and chest impacts with the vehicle components and serious risk of injury to the user and other vehicle occupants. (Fig B) The upper torso restraint belt should be mounted to the vehicle “B” pillar - failure to do so will increase the risk of serious abdominal injuries to the user. 10. Where there is a need for a head restraint when the user is being transported, in their wheelchair, as a seat in a vehicle, then a head restraint suitable for transportation must be fitted, and suitably positioned during the transportation of the wheelchair user. 11. Postural supports (lap straps, lap belts) should not be used or relied on for occupant restraint in a moving vehicle unless they are labelled as meeting the requirements specified in ISO 7176-19:2001 or SAE J2249.
DANGER!
There is a risk of serious injury or death if this if this advice is ignored!
Always make sure that your wheelchair is suited to transport the user within a vehicle. The symbols on the product label will help you to identify whether your wheelchair is crash-tested and therefore suited to transport the user within a vehicle:
Transportation of your wheelchair within a vehicle:
A wheelchair secured in a vehicle will not provide the equivalent level of safety and security as a vehicle seating system. It is always recommended that the user transfers to the vehicle seating. It is recognised that this is not always practical for the user to be transferred and in these circumstances, where the user must be transported whilst in the wheelchair, the following advice must be followed:
1. Confirm that the vehicle is suitably equipped to transport a passenger in a wheelchair, and ensure the method of access/egress is suitable for your wheelchair type. The vehicle should have the floor strength to take the combined weight of the user, the wheel chair and accessories. 2. Sufficient space should be available around the wheelchair to enable clear access to attach, tighten and release the wheelchair and occupant tie down restraints and safety belts. 3. The occupied wheelchair must be located in a forward facing position and secured by the wheelchair tie down and occupant restraint straps (WTORS tie downs meeting the requirements of ISO 10542 or SAE J2249) in accordance with the WTORS manufacturer’s instructions. 4. The wheelchair’s use in other positions within a vehicle has not been tested e.g. transportation in a side facing position must not be carried out under any circumstances (Fig. A).

Fig.B

RESTRAINT
BELT
PELVIC RESTRAINT
BELT
Fig.A
Crash Tested · Not Crash Tested

12. The safety of the user during transportation depends upon the diligence of the person securing the tie-down restraints and they should have received appropriate instructions and/or training in their use. 13. Wherever possible remove and stow safely away from the wheelchair all auxiliary equipment, for example: Crutches, Loose cushions and Tray Tables. 14. Articulating/elevating leg rest should not be used in the elevated position when the wheelchair and user are being transported and the wheelchair is restrained using Wheelchair Transport and Occupant Restraints. 15. Reclining backrests should be returned to an upright position. 16. The manual wheel locks must be firmly applied. 17. Restraints should be mounted to the vehicle “B” pillar and should not be held away from the body by wheelchair components such as armrest or wheels.
USER WEIGHT LESS THAN 22 kg (48 lb 8.0 oz) When the user being transported is a child, less than 22Kg mass and the vehicle involved has less than eight (8) seated passengers it is recommended that they be transferred to an UNCE Regulation 44 compliant child restraint system (CRS). This type of restraint system provides a more effective occupant restraint system than the conventional 3 point occupant restraint system and some CRS systems also include additional postural supports to assist in maintaining the position of the child when seated. Parents or care providers may consider the option, in some circumstances, for their child is to remain in their wheelchair whilst in transport due to the level of posture control and comfort provided by the set up in the wheelchair. We would recommend in such circumstances that a risk assessment be carried out by your healthcare professional and relevant competent persons.
Occupant Restraints Instruction:
1. The pelvic restraint belt must be worn low across the front of the pelvis so that the angle of the pelvic belt is within the preferred zone of 30 to 75 degrees to the horizontal. A steeper (greater) angle within the preferred zone is desirable i.e. closer to, but never exceeding 75 degrees. (Fig C). 2. The upper torso restraint belt must fit over the shoulder and across the chest as illustrated Fig d and e Restraint belts must be adjusted as tightly as possible consistent with user comfort. Restraint belt webbing must not be twisted when in use. The upper torso restraint belt must fit over the shoulder and across the shoulder as illustrated in Fig D and E.
Transportability – positioning of wheelchair tie down restraints on wheelchair
The wheelchair secured with front wheelchair tie down restraints. (Fig. G). Position of the rear wheelchair tie down restraint, (Fig H).


Fig.C

Fig.E
Fig. G
ZONE

Fig.D

Fig. H
Fig.F


THIS GUARANTEE DOES NOT AFFECT YOUR LEGAL RIGHTS IN ANY WAY.
Sunrise Medical* provides a guarantee, as set out in the warranty conditions, for wheelchairs to its customers covering the following.
Warranty conditions:
a. Normal wear and tear, which include batteries, armrest pads, upholstery, tyres, brakes shoes, etc. b. Any overloading of the product, please check the EC label for maximum user weight. c. The product or part has not been maintained or serviced in accordance with the manufacturer’s recommendations
as shown in the user instructions and/or the service instructions. d. Accessories have been used which are not specified as original accessories. e. The wheelchair or part having been damaged by neglect, accident or improper use. f. Changes/modifications have been made to the wheelchair or parts, which deviate from the manufacturer’s
specifications. g. Repairs have been carried out, before our Customer Service has been informed of the circumstances.
* Means the Sunrise Medical facility from which the product was purchased.
Additional Notes For Australia Only:
i. For goods provided by Sunrise medical Pty Ltd in Australia, our goods come with a guarantee by Sunrise Medical that cannot be excluded under Australian Consumer Law. ii. You are entitled to a replacement or refund for a major failure and for compensation for any foreseeable loss or damage. iii. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure. iv. The benefits to you given by this warranty are in addition to your other rights and remedies under a law in relation to
the goods to which the warranty relates.


First remove the seat cushion from the wheelchair and flip up the (platform) footplate. Take hold of the sling or the seat tubes (Fig.4.1) in the middle, from the back, and pull it upwards until the folding bracket (Fig.4.2) clicks into place.
To move the mobility aid, the folded wheelchair should be lifted by holding the front part of the cross-brace and the push handles.

Push the release lever of the folding bracket (Fig.4.3) downwards and push both frame halves apart. Then press on the seat tube (see figure). Your wheelchair is then unfolded. Now snap the seat tubing into position in the seat saddle. This can be facilitated by slightly tipping your wheelchair to the side, as this means that the weight is taken off one of the rear wheels. Be careful not to get your fingers caught in the cross-tube assembly. Fit the seat cushion. (Fig.4.4).




Folding up · Transport · Unfolding


Quick-release axles on rear wheel The rear wheels are equipped with quick-release axles. The wheels can then be fitted or removed without using tools. To remove a wheel, simply depress the quick-release button on the axle and pull the wheel off the axle. (Fig.5.1).
Quick release for quads/tetraplegics Please flip up the release lever (1). The take out the quick release axles and/or the wheels. When the wheels/quick release axles have been put on the chair again, please flip the release lever down. Please do always ensure that the release mechanism is closed and fully locked before starting to use the wheel chair (Fig. 5.2).


Step tubes are used by attendants to push a wheelchair over an obstacle. Simply step on the tube to push a wheelchair, for example, over a kerb or step, (Fig.6.1.1).

Braking power can be affected by incorrect fitting and adjustment of the wheel locks, as well as tyre pressure which is too low. Wheel locks
Your wheelchair is equipped with two wheel locks. They are applied directly against the tyres. To engage, press both wheel-lock levers forward against the stops. To release the wheel, pull the levers back to their original positions.

3.0 mm
The wheel locks have not been designed to be used as wheel locks for a moving wheelchair. The wheel locks should therefore never be used to wheel locks a moving wheelchair. Always use the hand rims for braking. Make sure that the interval between the tyres and wheel locks complies with given specifications. To readjust, loosen the screw and set the appropriate gap. Then re-tighten the screw, (Fig.6.2.1 and Fig.6.2.2).
After each adjustment of the rear wheels, check the wheel lock gap and re-adjust if necessary.

Wheel Lock Lever Extension

The longer lever helps to minimise the effort needed to set the wheel locks. The wheel lock lever extension is screwed to the wheel locks. By raising this, it can be flipped forward. (Fig.6.2.3).
Mounting the wheel lock too close toward the wheel will result in a higher effort to operate. This might cause the wheel lock extension lever to break!
Leaning onto the wheel lock lever extension while transferring will cause the lever to break! Splashing water from tyres might cause the wheel lock to malfunction.

Compact wheel locks are underneath the seat sling and are operated by pulling the wheel locks towards the rear, in the direction of the tyre. For the wheel locks to operate correctly, they must be pulled fully against the stops, (Fig.6.2.4).

Drum brakes permit safe and convenient braking for an attendant. They can also be set with the aid of a locking lever (1) to prevent rolling. The lever must snap audibly into place. Drum brakes are not influenced by air pressure inside the tyres (Fig.6.2.5).
Compact Wheel lock · Drum brakes


Various footboards are available on the Xenon. These can flipped up to make it easier to transfer to/from the chair. They are described individually.
By undoing the clamp screw (Fig.6.3.1), you can adjust the lower leg length. Loosen the clamp screw, adjust the tube with the footboard to the desired position. Tighten clamp screws again (see the page on torque). Ensure that the plastic push joint is located under the clamp screw in the correct position.

The footplates can be flipped up to make it easier to transfer to and from the chair. The footplates can also be tilted to six different angles relative to a level surface. Tighten screw (1) firmly on the outer side. By removing the clips (2), the footrest can be adjusted to three different positions toward both the front and rear. Loosen the adjustment screw (3) to change the horizontal position of the footboard. For this purpose, the footboard must be flipped up, (Fig.6.3.2 to Fig.6.3.4). When finished, make sure that all screws have been properly tightened (see the page on torque). A minimum interval of 2.5 centimetres from the ground should always be maintained.


Lower leg length · Platform Footrests

Width adjustment of footrests

If the footrest width needs to be adjusted, please undo the screw (1), set the desired width, by positioning 1, 2 or 3 spacers (2) from outer to the inner side and then refit the screws, (Fig.6.3.5).
The footboard angle can be adjusted by loosening the screws (2). Side protection panels can be fitted to the footboard using the mounting holes (3) These prevent the feet slipping off accidentally, (Fig.6.3.6). Make sure that after any adjustment work, all screws are tightened correctly (see the page on torque).

To adjust the width of the footboard open the screw (2). Then you can slide in and out the tubes in the holder to adjust the width of the footboard (Fig.6.3.6). Please make sure that the screws are tightened with the correct torque .
The footrest angle can be adjusted by loosening the screws (1) and turning the footrest. When tightening, please note the torque measurements, (Fig.6.3.7).

The high-mount footrest is fitted on the inner part of the frame and permits a higher position than a standard footrest (Fig.6.3.8)




The seat sling can be adjusted for tension by using several straps. To adjust the tension of the seat sling all straps have to be open. By pulling the straps the tension of the seat sling will be tightened, (Fig.6.4.1).
Adjusting the seat height:
To change the seat height;


To change the seat height:
Seat Sling · Lightweight adapter · Standard adapter

COG, (Centre of Gravity), Setting

To carry out COG adjustment, there are basically 2 different options. Adjustment can be carried out directly on the axle bracket (Standard adapter only ) by shifting the crescent-shaped spacers from one side to the other. To make an adjustment in larger steps, you must change the position of the axle-stem on the frame.

Changing the position of the axle stem
Using the quick-release axles, take the wheels out of the angle adapter. Undo both screws (1) and remove these completely. Fit the axle stem in the desired position on the frame, put the screws back into the perforated plate and then re-tighten the screws. When moving the axle stem, also move the seat saddle on the frame, (change the axle stem and the seat saddle). Make sure that the left and right sides are fitted in the same positions. Use the given torque of 8 Nm (Fig.6.4.4 to Fig.6.4.5).
COG setting on the standard axle bracket

Adjustment can be carried out directly on the axle bracket (standard axle bracket only) by shifting the crescent-shaped spacers from one side to the other. 3 Positions are possible (Fig.6.4.6 to Fig.6.4.8). Using the quick-release axles, take the wheels out of the axle adapter (4). Release the Allen screws (1) with an Allen key. Take the lid (2) of the axle bracket off and arrange the crescent-shaped spacers (3) according to your desired COG. Put the lid back on. Re-tighten the Allen screws (1), using a two-stage process: a) Tighten both Allen screws to a torque of 5 Nm. b) Tighten both Allen screws for a second time to a torque of 8 Nm.




Setting the Castor, Castor adapter & Castor fork
If the wheelchair veers slightly to the right or left, or the castors flutter, it may be caused by one or more of the following:
The optimum adjustment of the castors is required so that the wheelchair runs in a straight line. Castors should always be adjusted by an authorised dealer. The castor plates must be re-adjusted, and the wheel receiver must be checked every time the rear wheel position has been altered.

To ensure that both forks are set parallel, simply count the teeth visible on both sides. After setting the castor fork, the teeth will guarantee a secure position, allowing an adjustment of 16° in 2° increments, (Fig.6.5.1). Use the flat side on the front of the castor fork to check for a right- angled position to the ground.
The patented design allows the castor fork to be turned, so that it can be reset at right-angles to the ground when the seat angle is changed.
Setting the directional stability
Release the Allen screws (1) on the underside of the fork. You can then remove the screws (2). You can now turn the black socket (3) left or right. Left – chair pulls to the left Right – chair pulls to the right Then re-tighten the screw (2). Please set a 90° angle from the fork to the floor. Then re-tighten the screw (1). (Fig.6.5.2).
Some of the screws used during manufacturing are coated with thread-locking fluid (blue dot on the thread) and can only be adjusted up to 3 times before they need to be replaced by new thread-locking screws. Alternatively, the screws can be re-mounted using Loctite™ 243 thread locker.
Adjusting the castor


To adjust the back angle, please undo the Allen screw (1) and remove it. Set the desired position and then refit the Allen screw in this position and tighten it to the given torque. (Fig.6.6.1).
To make it easier to transport the wheelchair, the top half of the backrest can be folded down. To do this, press both levers (1) and fold the backrest down. When folding the backrest back up, please make sure that both sides are firmly interlocked (Fig.6.6.2 to Fig.6.6.3).

The adjustable back sling can be adjusted for tension by using several straps, (Fig.6.6.4).

The backrest may be set to various back heights, in 25 mm steps (4 adjustment ranges: 250-300 mm, 300-400 mm, 400-450 mm and 450-475 mm). Remove the side pads of the upholstery and if necessary the backrest belt covering the screws. Release the screw (1) and set the backrest to the desired height, then tighten the screws again, (Fig.6.6.5). See the page on torque.

Please take into account the altered centre of gravity when setting the angle of the backrest.
The headrest (Fig. 6.7.1) can be raised and moved horizontally both forwards and backwards. To do this, loosen the screw (1,2 or 3). Now you can adjust to the desired position. Tighten screws again (see the page on torque).




NOTE: To achieve the very best movement, the rear wheels must be adjusted to their optimum position, which means correctly adjusting the wheel alignment. To do this, measure the distance between both wheels front and rear to ensure that they are parallel to one another. The difference between both measurements should not exceed 5 mm. The parallel setting can be adjusted by loosening the screws, (1) and rotating the axle adapter (3). When finished, make sure that all screws have been properly tightened, (Fig.6.8.1 to Fig.6.8.2). Re-tighten the Allen screws to 8 Nm.

Be careful, there is a risk of tipping when adjusting the centre of gravity of the seat!
Adjusting the rear wheelbase width
The rear wheelbase is defined as the distance between the upper side of the rear wheels and the backrest tubes and is factory set, (125 mm). This must be increased if more space is to be created between the tyres and the optional height-adjustable armrests.
When adjusting the rear wheelbase:


mounted on the wheelchair frame. b. The armrest will automatically lock into place.
stop point. b. Push the arm pad up or down to reach the desired height. c. Set the lever back to the interlocked position against the
armrest rails. d. Push the arm pad (4) until the rails click into place securely.

place.
Mounting Components For The Armrest Receiver
Adjusting the armrest receiver To tighten or loosen the fit of the outer armrest rails in the receiver: 1. Loosen the four set screws for the receiver (D) on the sides of the receiver. 2. Leave the armrest in the receiver (E) and push the receiver together, until the desired adjustment is achieved. 3. Tighten the four screws (D). (144 in-lbs, 16.3 Nm)

Position adjustment 1. Loosen the two clamp screws (10) until the clamp is loose. 2. Push the armrest receiver to the desired position. 3. Tighten. (Fig.6.9.1 to 6.9.4).


Side-guard with clothes protector

The clothes protector prevents clothes getting dirty from spray water, (Fig.6.9.5). You can set the position in relation to the rear wheel by moving the side-guard. To do this, remove the screws (1 and 2). After setting to the desired position, re-tighten the screws (see the page on torque).

Neither the side-guards nor the armrests are to be used for lifting or carrying the wheelchair.
These handles are secured with pins to prevent them from sliding out unintentionally. By releasing the tension lever (1) the height of the push handles (2) can be set individually. If the lever is moved, listen to make sure that it clicks into place. The push handle can easily be set to the desired position. The nut on the tension lever determines how tightly the push handles are clamped into place. If the nut is loose after adjusting the tension lever, the push handle will also be too loose. Turn the push handle from side to side before use to make sure that it is clamped into place securely. After adjusting the handle height, always clamp the tension lever (1) securely into place. If the lever is not secure, injuries could result when ascending stairs. (Fig.6.10.1).

If the height-adjustable push handles are not fitted properly, there is a risk that these will develop "play" or that they move out of position. Please make sure that the relevant screws are tightened correctly.
If the folding push handles are not required, they can be flipped downwards by pushing the button (1). When they are required again, flip the push handles up, until they click into place. (Fig.6.10.2).
Height-adjustable push handles · Folding push-handles


This device permits crutches to be transported directly on the wheelchair. It has a Velcro loop to fasten crutches or other aids, (Fig.6.11.1).
Never try to use or remove the crutches or other aids while moving.

Sunrise Medical recommends anti-tip tubes are fitted for all chairs. When fitting anti-tip tubes, use a torque of 7 Nm.
Anti-tip tubes prevent the wheelchair from tipping backwards, providing additional safety for new users and for users familiarising themselves with the operation of the wheelchair.

Slotting the anti-tip tubes into the clamp
Adjusting the anti-tip tubes
To achieve the correct ground clearance of approximately. 1“ to 2“ (25 mm to 50 mm), the anti-tip tubes must be set higher or lower:
Push down on the top of the anti-tip tube, (1), to bring them into position, (Fig.6.12.2). A 30 - 50 mm gap should be maintained between the anti tip wheels and the ground. The anti-tips can also be swung into a forwards position. The anti-tips must always be in the forward position when negotiating large obstacles, (such as kerbs), to prevent them from interfering with the manoeuvre.
If the anti-tip tubes are not fitted, or have been fitted incorrectly, there is a risk of tipping over and of injury.
Crutch holder · Plug in Type · Swing-away Type


This bar is used to stabilise the backrest. To be able to fold the wheelchair, the release lever must be pushed inwards (Fig.6.13.1) or released and the stabilising must be flipped downwards. When unfolding the wheelchair, please make sure that the stabilising bar is locked into position.

Transit wheels should be used whenever your wheelchair would be too wide if the rear wheels were fitted, (Fig.6.14.1). After the rear wheels have been removed with the aid of the quick-release axles, the transit wheels can immediately be used to continue riding, (Fig.6.14.2). The transit wheels are mounted so that they are approximately 30 mm above the ground when not in use. They are therefore, out of the way when riding, transporting, or when tipping to pass over obstacles.

Folding stabilising bar · Transit wheels



If the strap is too loose, this could cause the user of the wheelchair to slip down and risk suffocation or serious injury.
The pelvic restraint belt is fitted to the wheelchair as shown in Fig.6.15.1 to Fig.6.15.10. The seat belt comprises two halves. They are fitted using the existing seat stay retaining bolt fitted through the eyelet on the belt. The belt is routed under the rear of the side panel. (Fig.6.15.1).
Adjust the pelvic restraint belt to suit the user’s needs as follows:

Adjust the belt position so buckles are in the centre of the seat. (Fig.6.15.2).
Feed free belt back through male buckle and slide adjusters. Ensure belt is not looped at male buckle, (Fig.6.15.3).
Feed free belt through slide adjusters and male buckle to provide more belt length, (Fig.6.15.4 to Fig.6.15.6).





When fastened check space between the pelvic restraint belt and user. When correctly adjusted it should not be possible to insert more than the flat of the hand between the pelvic restraint belt and the user, (Fig.6.15.7).
The pelvic restraint belt should be fixed so that the belt sits at an angle of 45 degrees across the user's pelvis. The user should be upright and be as far back as possible in the seat when correctly adjusted. The pelvic restraint belt should not allow the user to slip down in the seat, (Fig.6.15.8).

To fasten buckle: Firmly push male buckle into female buckle, (Fig.6.15.9).
To release buckle: Press the RED button in the centre of the buckle then pull the two halves gently apart, (Fig.6.15.10).

See the transit brochure from Sunrise Medical for further information on transportation.
Maintenance:
Check pelvic restraint belt, and securing components, at regular intervals for any sign of frays or damage. Depending on usage, it may need to be replaced.

The pelvic restraint belt should be adjusted to suit the end user as detailed above Sunrise Medical also recommends that the length and fit of the belt is checked on a regular basis to reduce the risk of the end user inadvertently re-adjusting the belt to an excessive length.


It is necessary to adjust the hand-bike axle to bias the centre of gravity rearwards. This allows safe use of a hand-bike accessory, (Fig.6.16.1).



To assemble the hand-bike reinforcement kit:

B
The tension of both cables must be checked for tightness before and after each use of the hand-bike.
Hand-Bike-Axle · Hand-Bike Reinforcement Kit

As the user, you are the first person to notice any possible defects. We therefore recommend that before each use, you check the items in the following list:
If there is any damage or malfunction, please contact your authorised dealer.
Always make sure that you maintain the correct tyre pres- sure (min. 3.5 bar) as this can have an effect on wheel- chair performance.
If the tyre pressure is too low, rolling resistance will increase, requiring more effort to move the chair forward. Low tyre pressure also has a negative impact on manoeu- vrability.
Sand and sea water (or salt in the winter) can damage the bearings of the front and rear wheels. Clean the wheelchair thoroughly after exposure.
The following parts can be removed and sent back to the
If the tyre pressure is too high, the tyre could burst.
manufacturer/dealer for repair:
The correct tyre pressure for a given tyre is printed on the surface of the tyre (min. 3.5 bar). Tyres can be mounted the same way as an ordinary bicy- cle tyre. Before installing a new inner tube, you should always make sure that the base of the rim and interior of the tyre are free of foreign objects. Check the pressure after mounting or repairing a tyre. It is critical to your safety and to the wheelchair’s performance that regulation air pressure be maintained and that tyres are in good condition.
Rear wheels-Armrest-Footrest holder-Anti-Tip tubes
These components are available as spare parts. For further information, please see the spare parts catalogue.

Hygiene measures when being re-used:
Prior to the wheelchair being re-used, it must be carefully prepared.
All surfaces which come into contact with the user must be treated with a disinfection spray. To do this, you must use a disinfectant from the DGHM list, e.g. Antifect Liquid (Schülke & Mayr) for rapid alcohol- based disinfection for medical products and medical devices, which must be disinfected quickly. Please take into account the manufacturer's instructions for the disinfectant you are using. In general, a complete disinfection cannot be guaranteed on seams. We therefore recommend that you dispose of seat and back slings to avoid micro bacterial contamination with active agents according to § 6 infection protection law.
In the following section, there is a description of the mate- rials used on the wheelchair, in view of the disposal or recycling of the wheelchair and its packaging. There may also be special local regulations in force with regard to disposal or recycling, these must be taken into account when disposing of your wheelchair. (This can include the cleaning or decontamination of the wheelchair prior to disposal).
Aluminium: Castor forks, wheels, chair side guards, armrest frame, footrest, push handle Steel: securing points, quick-release axle Plastic: Handles, tube stoppers, castors, footplates, arm pads and tyres Packaging: Plastic bags made of soft polyethylene, card- board Upholstery: Polyester fabric with PVC coating and high- ly-flammable foam.
Disposal or recycling should be carried out by a disposal company or at a public disposal point. You can also return your wheelchair to your dealer for disposal.


13.0 Technical Specifications
The nameplate is located on either the cross-tube assem- bly or the transverse frame tube, as well as on a label in the owner’s manual. The nameplate indicates the exact model designation and other technical specifications. Please provide the following pieces of information when- ever you have to order replacement parts or to file a claim:

Maximum weight limit: Xenon up to a load of 110 kg or 140kg, depending on frame version.
XXXX.XX.XX Xenon2 XXXXXX
Seat heights: The choice of frames, forks and castors as well as the size of the rear wheel (610mm (24")), (635mm (25")); determines what seat heights are possible.
XXX mm XXX mm Max.XX° XXX kg
Product Name/SKU Number.
The wheelchair conforms to the following standards: 1. Requirements and test methods for static, impact and fatigue strengths (ISO 7176-8) 2. Flammability resistance of upholstered parts in accord- ance with ISO 7176-16 (EN 1021-1/2)
Maximum safe slope with anti-tip tubes fitted, Depends on wheelchair setting, posture and physical capabilities of the user.
Seat width.
Depth (maximum).
Load Maximum.
User's Guide.
Date of manufacture.
Serial number.
Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.