to a cold water line.
This appliance is intended for domestic use and the household environment only.
connection to DVGW-tested plastic pipes.
scribed in the text and illustrations. We do not accept liability for damage resulting from failure to heed these instructions.
cable from the supply and shut off the water supply before connecting the appliance!
altitude of 2000 m above sea level.
connect the electrical supply.
stored in a frost-free room (due to residual water).
quired for installation on the rear of the appliance. If the appliance is reinstalled, the unused openings must be provided with watertight sealing.
Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs. Immediately shut off the cold water supply to the appliance should it leak.
installation.
connected and put into operation by a qualified professional.
from the electrical mains supply when working on the water supply. After service work is complete, proceed as during the first-time appliance start-up.
ing drinking water for household use.
necting the power supply beforehand.
aged 8 years and older as well as by per- sons with diminished bodily, sensory or mental perception, or those who lack knowledge or experience, if they are moni- tored or have received instruction concern- ing use and comprehend the possible dan- gers that can result. Children may not play with the appliance. Cleaning and mainte- nance by the user may not be performed by unsupervised children.
country, as well as those of the local electric- ity and water suppliers, must be adhered to.
appliance and must be connected to the protective earth.
connected to installed pipes. The conduc- tor cross-section must comply with the installed appliance power.
appearance of a connected protective earth.
do not play with the appliance.
regulations, an all-pole separator must be fitted during installation. The contact opening must be at least 3 mm.
be hot. Please inform and instruct children appropriately.
for closed (pressurised) operation.
proved for operation with closed (pressur- ised) continuous-flow heater systems.
suitably qualified specialist.

Congratulations on purchasing this Siemens appliance. You have acquired a top-quality product, which will give you a lot of enjoyment.
warm water tap fully and flush out the appliance thorough- ly for 1 minute.
Please read this installation and operating instruction manual carefully, then act accordingly! Store for future reference.
regulating valve.
Installation instructions
bottom. The sheath of the connection cable must extend for at least 40 mm into the appliance.
Install the continuous-flow heater as described in the illustrated section. Observe the instructions in the text.
The illustrations can be found in the centre of the instruction manual.
undertaken by the respective utility operator or by a quali- fied specialist company, who can also assist you when you are requesting the approval of the utility company for installation of the appliance.
The device is compliant to IEC 61000-3-12.
appliance, in an environmentally conscious manner.
switches on even when water is drawn from several cold- water taps simultaneously. If not, remove the flow limiter (refer to additional information A).
tinuous-flow heater.
tion cable) must be disconnected from the power supply. Unscrew the fuse or switch off the circuit breaker.
III. Wall mounting
operate the continuous-flow heater at full power, but re- move the flow limiter (Fig. A, 3.).
the wall. If required, secure the appliance using the lower adjusting screws.
age heaters (Fig. B).
compensate for any unevenness in the wall surface.
the sleeve is damaged during installation, the holes must be sealed water-tight.
Installation note

* Plus any pressure loss at the tap mixer
Special accessories
as an under sink appliance
for operation with the priority circuit

Please read and observe the detailed safety instructions at the start of these instructions!
the fuses in the fusebox).
pipe.
Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs.
The appliance is ready for operation.
ance should it leak.
Use the “e” setting whenever possible. For wash basins: Open the corner valve to such an extent that only the lower heat setting switches on.
The continuous-flow heater heats the water as it flows through the appliance. The appliance only consumes power during this period.
The continuous-flow heater has two heat settings: e Economy setting – two thirds power II Intensive setting – full power
please reduce the water quantity on the tap until the re- quired water temperature is achieved.
The e setting is ideal for:
Simply wipe the appliance with a damp cloth. Do not use acidic or abrasive cleaning materials.
The II setting is used in combination with a thermostatically- controlled premixer, for high temperatures or for large vol- umes of water, e. g. for:
If you call the after-sales service for assistance, please specify the E no. and FD no. of your appliance. These numbers are found on the inside of the swing-out con- trol panel of the continuous-flow heater.
The continuous-flow heater switches on and heats the water when the hot-water tap is turned on (Fig. E, 1.).
It switches off again when the tap is turned off.
Slightly close the hot-water tap (Fig. E, 2.).
Turn on the cold-water tap (Fig. E, 3.).

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service personnel.
If the fault could not be eliminated, please call customer service.
Guarantee
This appliance is labelled in accordance with Euro- pean Directive 2012/19/EU concerning used elec- trical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as appli- cable throughout the EU.
The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold.
Details regarding these conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim un- der the terms of this guarantee.
Please ask your specialist retailer about current disposal facilities.
Subject to change without notice.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| Water flow-rate is too low. The appliance does not switch on. | The filter in either the water tap or the showerhead is clogged. | Remove the filter and either clean it or descale it. | p.5 |
| Water flow-rate is too low. The appliance does not switch on. | The filter in the corner valve is clogged. | Get a servicing expert to clean the filter. | p.5 |
| Water flow-rate is too low. The appliance does not switch on. | The corner valve is clogged. | Turn on the hot-water tap fully and open and close the corner valve several times. Then clean the filter in the water tap. | p.5 |
| The water is not sufficiently warm. | The fuse in the house electrical installation has tripped/blown. | Check the fuse in the fusebox. | p.5 |
| The water is not sufficiently warm. | The appliance‘s automatic circuit breaker has been tripped. | Get the appliance‘s automatic circuit breaker checked by an electrician. Check the permissible supply temperature. | p.5 |
| The water is not sufficiently warm. | The power limit has been reached. Water flow-rate is too high and/or the cold water supply temperature is too low. | Reduce the flow-rate on the tap. | p.5 |
| The water is not sufficiently warm. | By a qualified professional: use the corner valve to regulate the flow-rate. Check the flow-rate limiter or replace it with a smaller one. | p.5 | |
| The water is not sufficiently warm. | The second stage in the appliance does not switch on (the audible “clicking” is missing). | Remove the filter in the tap and either clean it or descale it. | p.5 |
| The water is not sufficiently warm. | Clean the filter in the corner valve (Fig. A, 4.). | p.5 | |
| The continuous-flow heater switches off during the drawing-off of water, result- ing in a reduction in the water temperature: | Swelling seal in the warm water tap | A non-swelling sealing material must be used in the warm water tap. | p.5 |
| Winter operation: The desired water tempera- ture leaving the tap is no longer reached. | The supply temperature has reduced. | Reduce the water flow on the taps until the desired water temperature is reached. | p.5 |
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.