

Gallagher W-Ϣ Weigh Scale User Manual
To ensure opƟ mum performance of the W-0, it is recommended that the internal baƩ ery is charged for a minimum of 10 hours before fi rst Ɵ me use.


Gallagher W-Ϣ Weigh Scale User Manual
BaƩ ery charge indicator Bluetooth

Weighing mode Shows AUTO when AutomaƟ c weight lock is turned on
Weigh buƩ on Records animal weight
Power buƩ on Turn W-0 On/Off
Mode BuƩ on Changes weighing mode and weighing units.
Zero buƩ on Sets the displayed weight to zero.

Loadbar connectors Either one or two loadbars can be connected to weigh.
Power Input External power connecƟ on 9 -15V
Fully Charged 25 - 50% charge Less than 25% charge 5% or less charge remaining
When the baƩ ery level drops to 0%, three beeps will sound and the red weight lock LED will fl ash three Ɵ mes. The scale will rapidly sound 4 beeps then shut down.
Weigh screen · Weight Unit

Gallagher W-Ϣ Weigh Scale User Manual
Turn on the W-0 scale.
To change the weight unit, press and hold down the Mode buƩ on for 3 seconds. A beep will sound when the weight unit changes between kgs and lbs.
Press the Mode buƩ on to turn Auto weight lock on or off . When AUTO is not displayed the scale is in Manual mode.
Weighing Modes

Gallagher W-Ϣ Weigh Scale User Manual

The W-0 can be placed on a table top or mounted on the bracket supplied.
The bracket can be mounted on a fl at verƟ cal surface, a round post, or a rail.
To mount the bracket on a fl at verƟ cal surface, or a round wooden post, use the 3 x tek screws included with the unit.



To mount the bracket on either a verƟ cal or horizontal bar, use the ‘U’ bolts included with the unit.

Gallagher W-Ϣ Weigh Scale User Manual
It is recommended that you use Gallagher Loadbars with the W-0 Scale. The W-0 recognises other most commonly available Loadbar sets. If you are not using Gallagher Loadbars. Steps to install loadbars 1. Select a weighing site that provides a solid, level and well drained surface. 2. Ensure the loadbars and plaƞ orm are well secured and clear of any obstrucƟ ons. 3. Either bolt the loadbars to the concrete pad or locate them on studs set into the concrete. It is important that the loadbars and plaƞ orm sit fl at without any rocking or twisƟ ng to avoid weighing inaccuracies. Note: It may be necessary to shim the loadbars or plaƞ orm to ensure there are no twisƟ ng pressures within the plaƞ orm. Weights should be evenly distributed over the top of the weigh bars. 4. Connect the loadbar cables to the W-0. A beep will sound indicaƟ ng a successful connecƟ on/ disconnecƟ on of the loadbars.


Gallagher W-Ϣ Weigh Scale User Manual
There are 2 ways to use the W-0 scale. It can be used on its own or used in conjuncƟ on with the Gallagher Animal Perfomance mobile app. Use the app if you want to record your session.
Before you begin weighing: 1. Check loadbars are connected to the W-0.
Open the Animal Performance app and if required, follow the prompts to create a Gallagher Account.

Gallagher W-Ϣ Weigh Scale User Manual



Ϥ
ϥ
Open the Gallagher Animal Performance app on your mobile device. From the Home screen, tap New Session, type in a session name and tap Done.
The app will begin searching for the W-0 and any other devices within range. Select the W-0 from the devices list and tap Connect.
The weigh screen will open and you are ready to begin weighing. Refer to Weighing Animals (p. 9)
Animal Count Session Name

Session Summary Animal VID
Heaviest Animal Lightest Animal
Lock Weight Zero Weight

Gallagher W-Ϣ Weigh Scale User Manual
If you are weighing animals without the Animal Performance app, once the scale is turned on and weight displayed is zero, you can start weighing your animals. Refer to Weighing Animals (below).

Gallagher W-Ϣ Weigh Scale User Manual
When a weighing session is completed (i.e. all animals weighed), the recorded session on the mobile app can be synced to the Animal Performance cloud soŌ ware.
From the Home screen, tap the Menu buƩ on, then tap Sync.


AŌ er syncing, the same data will be present on the W0 and in Animal Performance.

Gallagher W-Ϣ Weigh Scale User Manual
The W-0 is a tough and reliable product designed for use in typical livestock environments. Proper care and maintenance can extend its life.
It is important to update the W-0 soŌ ware from Ɵ me to Ɵ me to ensure you have the latest enhancements.
Updates are regularly released to enhance the features of the scale or to correct issues.
(top right of screen).

Gallagher W-Ϣ Weigh Scale User Manual
This device complies with Industry Canada licence-exempt RSS standard(s). OperaƟ on is subject to the following two condiƟ ons: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operaƟ on of the device.
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use by Gallagher Group Limited is under license. Other trademarks and trade names are those of their respecƟ ve owners.
Industry Canada

DECLARATION OF CONFORMITY We, Gallagher Group Ltd Kahikatea Drive Hamilton New Zealand www.gallagher.com Declare that the product:

G02500 W-0 WEIGHSCALE conforms to the Radio Equipment Regulations 2017 conforms to the RoHS Regulations 2012 Compliance has been demonstrated by testing the products to the following standards: ETSI EN 301489-1 V2.2.3 (2019-11) Report ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility
ETSI EN 301489-3 V2.1.1 (2019-03) Report ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU
This declaration is issued under the sole responsibility of the manufacturer, Gallagher Group Ltd. I hereby declare that the product defined above complies with the above standards and all products supplied under this Declaration will be identical to the sample tested.
Authorized Representative:
Position in Organisation:
Regional Manager Europe Gallagher Security (Europe) Ltd www.gallagher.com
Richard Huison · 23/12/2020



DECLARATION OF CONFORMITY We, Gallagher Group Ltd Kahikatea Drive Hamilton New Zealand www.gallagher.com Declare that the product:

G02500 W-0 WEIGHSCALE conforms to the Radio Equipment Directive: 2014/53/EU conforms to the RoHS Directive: 2011/65/EU Compliance has been demonstrated by testing the products to the following standards, either published in the Official Journal of the European Communities or referenced by the Radio Equipment Directive: ETSI EN 301489-1 V2.2.3 (2019-11) Report ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility
ETSI EN 301489-3 V2.1.1 (2019-03) Report ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU
This declaration is issued under the sole responsibility of the manufacturer, Gallagher Group Ltd. I hereby declare that the product defined above complies with the above standards and all products supplied under this Declaration will be identical to the sample tested.
Authorized Representative:
Position in Organisation:
Operations Manager Gallagher Europe B.V. www.gallagher.eu
Ronald Wassink · 23/12/2020

3E5318 03/21 Ed. 2
Gallagher Private Bag 3026, Hamilton, New Zealand
Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.