Gallagher TWR-ϧ Weigh Scale Quick Start Guide

SPECIFICATIONS

OperaƟ ng Temperature -20o to 50oC

-5o to 120oF

Environmental ProtecƟ on RaƟ ng IP67

Input Voltage 12 V DC

EsƟ mated baƩ ery run Ɵ me at 100% brightness at 60% brightness

Weigh only 12 hours 16 hours Weigh/Read 6 hours 8 hours Read only 3 hours 4 hours

CHARGING THE BATTERY

To ensure opƟ mum performance of the TWR-ϧ, the internal baƩ ery may need to be charged for up to 16 hours before fi rst Ɵ me use.

1. Connect the power adapter at the base of the unit and plug the TWRϧ into a power outlet and switch ON . The charging icon will display on the screen. Warning: The power adaptor is intended for indoor use only. Do not expose to rain or dampness. 2. When the charge shows 100% the TWRϧ is ready to use with or without the power adapter.
Gallagher Weigh Scale and Data Controller (TWR-5) — CHARGING THE BATTERY diagram (page 2)
Afb. 1
  • Note:
  • When the TWRϧ is in use, the ba Ʃ ery icon will display and show remaining charge.
  • When using the scale and the charge level falls below 10% the ba Ʃ ery icon will fl ash with a red outline. You will have about 30 minutes to complete the weighing session before the TWRϧ must be charged.
  • When the charge level becomes cri Ɵ cal the unit will shut down.
Gallagher Weigh Scale and Data Controller (TWR-5) — CHARGING THE BATTERY diagram (page 2)
Afb. 2
  • To check remaining run Ɵ me at current se ƫ ngs, from the Home screen, go to Se ƫ ngs

> About > BaƩ ery.

  • The ba Ʃ ery error icon will display if the ba Ʃ ery is too hot (above +45 o C)

or too cold (below 0oC). The Scale will keep operaƟ ng while plugged in but will not charge properly unƟ l at room temperature.

Page 3 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — Connec Ɵ ons
Pagina 3 · klik om te vergroten
Pagina 3

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

UNDERSTANDING THE TWR-5 WEIGHING UNIT

Find animal Look up and add animal to a session

On-screen Help Touch to display informaƟ on about the current screen

Gallagher Weigh Scale and Data Controller (TWR-5) — UNDERSTANDING THE TWR-5 WEIGHING UNIT diagram (page 3)
Afb. 3

Touch Screen Tap the screen icons, fi eld names or buƩ ons to view or enter data.

Weigh buƩ on Records animal weight

Power buƩ on

Zero buƩ on Sets the displayed weight to zero.

Home BuƩ on Return to the Home screen

NavigaƟ on keys These buƩ ons can be used to navigate the funcƟ ons of the scale as an alternaƟ ve to the touch screen.

Footer bar detail

Bluetooth status BaƩ ery charge indicator

Gallagher Weigh Scale and Data Controller (TWR-5) — Footer bar detail diagram (page 3)
Afb. 4 · Footer bar detail

Weighing mode AUTO - AutomaƟ c weight lock MAN - Manual weight lock

Connec Ɵ ons

Gallagher Weigh Scale and Data Controller (TWR-5) — Connec Ɵ ons diagram (page 3)
Afb. 5 · Connec Ɵ ons

Antenna connecƟ on (for panel reader antenna)

BaƩ ery charger

USB port (connect to PC)

USB port (for memory sƟ ck) Serial port (mini adapter supplied to change connector sex)

Loadbar connecƟ ons

Show 9 more labels / short text on this page
Remove animal · Weigh screen · Footer bar · Turn TWR-5 On/Off · Backspace/Delete · Space bar · Qwerty keyboard · Panel reader status · WiFi status
Page 4 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — Installing the Scale bracket
Pagina 4 · klik om te vergroten
Pagina 4

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

INSTALLATION

Gallagher Weigh Scale and Data Controller (TWR-5) — INSTALLATION diagram (page 4)
Afb. 6

Installing the TWRϧ

The TWR-ϧ can be placed on a table top or mounted on the bracket supplied.

Installing the Scale bracket

The bracket can be mounted on a fl at verƟ cal surface, a round post, or a rail.

To mount the bracket on a fl at verƟ cal surface, or a round wooden post, use the 4 x tek screws included with the unit.

Gallagher Weigh Scale and Data Controller (TWR-5) — Installing the Scale bracket diagram (page 4)
Afb. 7 · Installing the Scale bracket
Gallagher Weigh Scale and Data Controller (TWR-5) — Installing the Scale bracket diagram (page 4)
Afb. 8 · Installing the Scale bracket

To mount the bracket on either a verƟ cal or horizontal bar, use the ‘U’ bolts included with the unit.

Gallagher Weigh Scale and Data Controller (TWR-5) — Installing the Scale bracket diagram (page 4)
Afb. 9 · Installing the Scale bracket
Page 5 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — Position the TWRϧ :
Pagina 5 · klik om te vergroten
Pagina 5

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

Installing the loadbars

If using loadbars, follow these steps: 1. Select a weighing site that provides a solid, level and well drained surface. 2. Ensure the loadbars and plaƞ orm are well secured and clear of any obstrucƟ ons. 3. Either bolt the loadbars to the concrete pad or locate them on studs set into the concrete. It is important that the loadbars and plaƞ orm sit fl at without any rocking or twisƟ ng to avoid weighing inaccuracies. Note: It may be necessary to shim the loadbars or plaƞ orm to ensure there are no twisƟ ng pressures within the plaƞ orm. Weights should be evenly distributed over the top of the weigh bars. 4. For Wired Loadbars: Connect the loadbar cables to the TWR-ϣ. For Wireless Loadbars: The TWR-1 must be within 8-10m of the loadbars. Refer to the Gallagher Loadbars InstrucƟ ons for further installaƟ on informaƟ on. A beep will sound indicaƟ ng a successful connecƟ on/disconnecƟ on of the loadbars.

Position the TWRϧ :

Gallagher Weigh Scale and Data Controller (TWR-5) — Position the TWRϧ : diagram (page 5)
Afb. 10 · Position the TWRϧ :
  • clear of the pla ƞ orm to ensure it does not interfere with the fl ow of animals during the weighing cycle
  • within easy reach of the loadbar leads
  • within easy reach of the operator (for manual weighing)
Page 6 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — Attaching the TWR-5 to the Antenna Panel
Pagina 6 · klik om te vergroten
Pagina 6

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

Installing the Antenna Panel

The TWR-5 has an internal reader, that when connected to a Gallagher Antenna panel will capture the Electronic ID tag data.

To weigh animals in a crush, you will need:

  • Gallagher Antenna Panel kit
  • 4m Antenna Extension Cable G05600 or 6m Antenna Extension Cable G05602

To mount your Antenna panel, refer to the instrucƟ ons included with the panel.

Attaching the TWR-5 to the Antenna Panel

1. Ensure the TWR-5 is turned OFF. 2. On the Antenna Panel, unscrew the Amphenol connector locking nut from the Amphenol socket and pull it down to unplug from the Antenna Panel.
Gallagher Weigh Scale and Data Controller (TWR-5) — Attaching the TWR-5 to the Antenna Panel diagram (page 6)
Afb. 11 · Attaching the TWR-5 to the Antenna Panel

MounƟ ng bracket

Amphenol connector (2.)

MounƟ ng holes

MounƟ ng holes

3. Connect the extension cable to the Amphenol connector and Ɵ ghten, then connect the other end of the extension cable to the Antenna connector on the base of the TWR-5. 4. Tighten the locking nut. 5. Refer to Connec Ɵ ng Equipment to the TWR-5 (p. 8) to complete the EID Reader connec Ɵ on on the TWR-5.

Amphenol connector · Antenna Cable

Page 7 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — Auto Shutdown
Pagina 7 · klik om te vergroten
Pagina 7

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

FIRST TIME START-UP

The fi rst Ɵ me the TWR-ϧ is powered on, the First Time Start-Up screen will display. Tap the screen to update the language, Ɵ me, date and weight fi elds as required and then tap Save.

Gallagher Weigh Scale and Data Controller (TWR-5) — FIRST TIME START-UP diagram (page 7)
Afb. 12

To change any of these seƫ ngs later, they can be accessed via Seƫ ngs

on the right of the Home screen.

For more informaƟ on about this screen or any TWR-ϧ screen, tap

displayed in the top right corner of the screen. This will display the On-screen Help with more informaƟ on about what you see on the screen.

Auto Shutdown

When the TWR-ϧ is leŌ idle for more than 30 minutes it will automaƟ cally shutdown to preserve the baƩ ery.

Press the Power buƩ on to turn the unit back on.

Page 8 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — Connecting an EID Reader
Pagina 8 · klik om te vergroten
Pagina 8

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

CONNECTING EQUIPMENT TO THE TWR-5

Connecting to Wireless Loadbars

1. On the TWR-5, tap Seƫ ngs > Equipment ConnecƟ ons > Loadbars > Wireless. 2. The TWR-5 will search for the loadbars. When the loadbars have been located, tap to select them from the list, then tap Connect. Note: As per the Wireless Loadbar InstallaƟ on instrucƟ ons, your loadbars must be switched on and in range to display in the search list. 3. The connecƟ on process will take up to 30 seconds while pairing occurs between the loadbars and the TWR-5. Once completed, tap Done.

4. Create a new session, by tapping New > Quick Start . The current weight will display as 0.0kg. If it’s not 0.0, press the Zero bu Ʃ on. Apply some weight to the bars to confi rm the connec Ɵ on is working.

Connecting an EID Reader

  • The TWR-5 internal reader can be used with or without loadbars connected. To use the internal reader, you must fi rst connect the antenna panel. Refer to A Ʃ aching the TWR-5 to the Antenna panel (p. 6).
  • A Hand-held EID Reader or permanent reader can be connected to the TWRϧ by either a serial cable or via Bluetooth®.
5. If using a hand-held reader or permanent reader, turn On the EID Reader. 6. For all readers, turn On the TWRϧ .
7. On the TWRϧ , tap Se ƫ ngs

> Equipment ConnecƟ ons > EID Reader. 8. Select how the Reader is being connected. This will be by Bluetooth, Serial cable, USB or using the internal reader (Panel). If using the internal reader, a successful connecƟ on will show as

in the footer bar. Note: A mini serial adapter is included with the TWR-ϧ if a female serial connecƟ on is required.

Page 9 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — START A SESSION
Pagina 9 · klik om te vergroten
Pagina 9

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

Refer to Bluetooth – Connect EID Reader in the TWR-5 On-screen Help or your EID Reader User Manual for further informaƟ on on pairing the reader.

Connecting to a Drafter/Sorter To connect the TWR-ϧ to a draŌ er, use the data cables supplied with your draŌ er. Refer to your DraŌ er User Manual for more informaƟ on. 1. Turn On the TWR-ϧ.

2. On the TWRϧ , tap Se ƫ ngs

> Equipment ConnecƟ ons > DraŌ er. 3. Specify the type of draŌ er that is being connected, to complete the setup.

If your draŌ er is not listed, tap Create Custom and follow the confi guraƟ on wizard set up your draŌ er.

START A SESSION

When you gather informaƟ on about an animal, it is recorded in a Session. Each event such as weighing, adds a record to the current session. A template using pre-determined defaults can be set up and used each Ɵ me you start a new session. Note: It is recommended a new session is opened for a new day’s acƟ vity or for a new group of animals. An animal cannot appear within the same session more than once. To start a new weighing session:

1. From the Home screen, tap New . T he New Session screen is displayed.
2. Tap Quick Start to open the Weigh screen with the scale default se ƫ ngs. Note: To set up and use templates, refer to the TWR-5 On-board Help.
Gallagher Weigh Scale and Data Controller (TWR-5) — START A SESSION diagram (page 9)
Afb. 13

To customize the session: click on the OPTIONS buƩ on at the lower leŌ of the screen. Here you can set up the weighing mode, draŌ ing opƟ ons, traits and name for the session. Refer to Session OpƟ ons (p. 11) for more informaƟ on.

3. Load the animal onto the pla ƞ orm.
Page 10 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — START A SESSION
Pagina 10 · klik om te vergroten
Pagina 10

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

4. If using the internal reader, the animal’s Electronic ID will be scanned, or you can scan with a hand-held reader and record the animal’s Visual Tag Number. Note: The internal reader will only read a tag when loadbars are connected and weight is detected on the weighing pla ƞ orm.
5. If weighing in AUTO - Automa Ɵ c weight lock , the scale will lock on to the weight and hold it on the screen un Ɵ l the animal leaves the pla ƞ orm.

If weighing in MAN - Manual weight lock, you must fi rst press Weigh

. When the weight becomes stable, it will lock.

6. Move the animal off the pla ƞ orm.
  • Other informa Ɵ on, for example: Notes, can be entered once the weight has locked or an ID has been entered.
  • In either mode, you can re-weigh an animal by pressing Weigh

aŌ er a successful weight lock.

  • If dra Ō ing is turned on, the gate number and group will display, in top right corner of the screen, indica Ɵ ng the dra Ō ing category. Tap this box to override the dra Ō ing decision.
  • By default the scale will automa Ɵ cally zero any debris le Ō on the pla ƞ orm between 2-5kg depending on the capacity of your loadbars. This can be altered in the connected loadbar se ƫ ngs.
  • If using traits within a session, the selected traits will appear down the right side of the screen. A maximum of 9 traits can be used in any one session. Once an animal is iden Ɵ fi ed, simply tap the trait box to assign a value.

Reading tags with the Internal Reader

When the internal reader is connected it will display as

in the screen footer. • If no loadbars are detected, the internal reader will always be acƟ ve, ready to

read a tag and will display as

  • If loadbars are connected, the footer will display

unƟ l a weight is detected on the plaƞ orm.

Page 11 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — Session Options
Pagina 11 · klik om te vergroten
Pagina 11

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

  • The symbol will then change to

, as it reads the tag. The internal reader will go in and out of acƟ ve mode as it detects weight on the weighing plaƞ orm.

Session Options

Gallagher Weigh Scale and Data Controller (TWR-5) — Session Options diagram (page 11)
Afb. 14 · Session Options

The Session OpƟ ons menu is used to confi gure seƫ ngs for the current session.

From this screen, tap the required opƟ on to change the session name, turn draŌ ing On or Off , add traits to the session, change the weight lock mode and confi gure Advanced seƫ ngs.

Tap Save to keep any changes.

for step by step informaƟ on to set up draŌ ing, add traits to the session or to confi gure the Advanced seƫ ngs. New traits are set up in the Seƫ ngs menu before they can be added to a session.

Page 12 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — VIEW ANIMAL INFORMATION
Pagina 12 · klik om te vergroten
Pagina 12

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

VIEW ANIMAL INFORMATION

The informaƟ on collected during a session can be viewed from the session’s Weigh screen.

Gallagher Weigh Scale and Data Controller (TWR-5) — VIEW ANIMAL INFORMATION diagram (page 12)
Afb. 15

To view informaƟ on about all the animals in the session;

tap All Animals,

Gallagher Weigh Scale and Data Controller (TWR-5) — VIEW ANIMAL INFORMATION diagram (page 12)
Afb. 16

to view weight range of animals.

To view informaƟ on about an individual animal weighed;

Gallagher Weigh Scale and Data Controller (TWR-5) — VIEW ANIMAL INFORMATION diagram (page 12)
Afb. 17

Tap an animal VID to view this animal on the Weigh screen.

Gallagher Weigh Scale and Data Controller (TWR-5) — VIEW ANIMAL INFORMATION diagram (page 12)
Afb. 18

to view the history of weights for the selected animal, from the Weigh screen.

Show 4 more labels / short text on this page
tap · Tap · tap · Tap
Page 13 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — h Ʃ ps://am.app.gallagher.com/amc/dashboard
Pagina 13 · klik om te vergroten
Pagina 13

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

TRANSFER SESSION DATA

Download the Gallagher Animal Performance app from Google Play or the App Store.

If required, follow the prompts and create a Gallagher Account.

  • On the TWR-5, press the Synchronise icon
  • on the Home screen. Note: The fi rst Ɵ me you sync data from the TWR-5 you will be prompted to enter your registra Ɵ on creden Ɵ als on the scale.
  • The Syncing process will automa Ɵ cally begin and any diff erences in session and animal data on the TWR-5 or in Gallagher Animal Performance, will be updated. A Ō er syncing, the same data will be present on the TWR-5 and Animal Performance.
  • To view your animal data, open the Gallagher Animal Performance Mobile App and sync your data or login to the Gallagher Animal Performance Web App: h Ʃ ps://am.app.<a href="http://gallagher.com/amc/dashboard" rel="nofollow noopener" target="_blank">gallagher.com/amc/dashboard</a>

CARE AND MAINTENANCE

The TWR-ϧ is a tough and reliable product designed for use in typical livestock environments. Proper care and maintenance can extend its life.

  • Listed below are guidelines for keeping the TWRϧ in good condi Ɵ on.
  • Do not submerge the TWRϧ in any liquid.
  • Store in a cool, dry place. Avoid storing in direct sunlight.
  • A Ō er use, clean with a damp cloth. Take care not to scratch the display.
  • If storing the TWR-5 for a long Ɵ me, store with the ba Ʃ ery charged. So Ō ware Updates

It is important to update the TWR-ϧ soŌ ware from Ɵ me to Ɵ me to ensure you have the latest enhancements. Updates are regularly released to enhance the features of the scale or to correct issues. These updates can be accessed by signing into Gallagher Animal Performance on your PC:

h Ʃ ps://am.app.gallagher.com/amc/dashboard

1. Select So Ō ware ( ) from the Animal Performance naviga Ɵ on pane. 2. Follow the on-screen instruc Ɵ ons, and select the device to be upgraded. 3. Press Download to begin the so Ō ware update for your selected device.
4. The so Ō ware upgrade fi le will be saved to your Downloads folder. Copy it to a USB fl ash drive. 5. Turn off the TWRϧ and Insert the USB fl ash drive. 6. Turn on the TWRϧ . The USB s Ɵ ck is recognised and the upgrade process begins. 7. Follow the instruc Ɵ ons on the screen to complete the update.
Page 14 of the Gallagher Weigh Scale and Data Controller (TWR-5) user manual — APPROVALS AND STANDARDS
Pagina 14 · klik om te vergroten
Pagina 14

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

APPROVALS AND STANDARDS

This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collecƟ on point for the recycling of waste electrical and electronic equipment. The separate collecƟ on and recycling of your waste equipment at the Ɵ me of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more informaƟ on about where you can drop off your waste equipment for recycling, please contact your local city recycling offi ce or the dealer from whom you purchased the product. FCC

  • This device complies with part 15 of the FCC Rules. Opera Ɵ on is subject to the following two condi Ɵ ons: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired opera Ɵ on. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec Ɵ on against harmful interference in a residen Ɵ al installa Ɵ on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc Ɵ ons, may cause harmful interference to radio communica Ɵ ons. However, there is no guarantee that interference will not occur in a par Ɵ cular installa Ɵ on. If this equipment does cause harmful interference to radio or television recep Ɵ on, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separa Ɵ on between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit diff erent from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. Cau Ɵ on: Changes or modifi ca Ɵ ons not expressly approved by Gallagher Group Limited could void the user’s authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s). OperaƟ on is subject to the following two condiƟ ons: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operaƟ on of the device. Under Industry Canada regulaƟ ons, this radio transmiƩ er may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmiƩ er by Industry Canada. To reduce potenƟ al radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communicaƟ on. This radio transmiƩ er (IC: 7369A-G0260X) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna Types: - BR600 Small Antenna Panel (G03121) - BR1300 Large Antenna Panel (G031424) - Sheep Auto DraŌ er Antenna Panel (G05714)

The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use by Gallagher Group Limited is under license. Other trademarks and trade names are those of their respecƟ ve owners.

Industry Canada

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Gallagher Weigh Scale and Data Controller (TWR-5)

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Gallagher Weigh Scale and Data Controller (TWR-5)

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Gallagher Weigh Scale and Data Controller (TWR-5) handleiding-pdf

120 pagina's·5.2 MB·Weegschaal·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…