® Section 61180403L1-5B Issue 2, December 2004 CLEI Code: VAIMZ70J_ _ 61180403L1-5B 1 Trademarks: Any brand names and product name s included in this docum ent are trademarks, regi stered tradem arks, or trade nam es of their respecti ve holders. CONTENT S 1.
2 Issue 2, December 2004 61180403L1-5B •P L A R D 3 •T a n d e m •D P O • FX Ringdown • TO w/Sealing Code Features The basic features of the FXS/DPO include the following: • µ -law encoding and decoding • Supports ground start, lo op start, PLAR, DPO, and Tandem, TR08SP, TR08UVG, TR08AUTO, and FX Ringdown • Supports 900 ohm s (+2.
61180403L1-5B Issue 2, December 2004 3 Instructions for Inst alling the Module To install the FXS/DPO, perform the following steps: 1. If pres ent, remove the Access Module Blank (P/N 1 175099L1) from the appropriate access module slot of the T otal Acce ss chassis.
4 Issue 2, December 2004 61180403L1-5B Hardware Provisioning DIP switches SW1 , SW2 , SW3 , and SW4 are used to provision many of the FXS/DPO options. Ta b l e 4 on page 5 summ arizes the options pro visioned by the DIP switches. Figure 2 o n page 6 provides a grap hic detail of the four switches and the printed circuit board markings.
61180403L1-5B Issue 2, December 2004 5 T able 4. DIP Switches Sw .-Segment Label Function/Desc ription 1-1 D3/D4 D3 or D4 Signaling (PLAR only) 1-2 1-3 MODE 1/OFF MODE 2/OFF SW1-2 SW1-3 Mode Selected .
6 Issue 2, December 2004 61180403L1-5B Figure 2. DIP Switches Detail Sof tware Provisioning The FXS/DPO is provisioned by connecting a VT100 terminal or a computer ru nning a terminal emulation program to the craft interface ADMIN port located on the System Controller Unit (SCU ) front panel.
61180403L1-5B Issue 2, December 2004 7 . T able 5. FXS/DPO General Opti ons Function Optio n Description Mode Loop S tart Ground Start TR08 Single Part y (3) TR08 Universal VG (3) TR08 Auto (3) PLAR D4 PLAR D3 Ta n d e m (3) DPO FX Ringdown (3) TO w /S C (3) This option selects the signaling mode of the FXS/DPO.
8 Issue 2, December 2004 61180403L1-5B T able 6. FXS/DPO Mode Options Mode Description Loop Start This option selects ANSI T1.403 FXS Loop S tart mode of operation. Ground Start This option selects ANSI T1.403 FXS Ground Start mode of operation. TR08 Single Party This option selects GR-08-Core Loop S tart mode of operation.
61180403L1-5B Issue 2, December 2004 9 T able 7. FXS/DPO T andem Options Function Option Description Conversion Mode T andem Inactive Loop Start Ground Start This option sets the conversion from E&M (2-state) signali ng on the PCM interface to loop star t or ground start signaling on the loop.
Figure 3. FXS/DPO Menu Tree 1. Configuration 2. Provisioning 3. Status 4. Test 1. Digital Network Loopback 2. 1004 Hz Tone Test 2. 2-Wire Termination 1. 600 + 2.16 2. 900 + 2.16 Enter Value (-7.0...+9.0) 3. Transmit TLP 1. Loop Start 3. TR08 Single Party 2.
61180403L1-5B Issue 2, December 2004 11 4. T EST FEATURES The FXS/DPO supports the following tests for each port: • Digital Network Loopback • 1004 Hz Tone Generation • Network Hook Test • Customer Ringing Test These test are used to support circuit turn-up and maintenance efforts.
12 Issue 2, December 2004 61180403L1-5B T able 8. Specifications Performance Loop Current: T ransmit TLP: Receive TLP: T erminating Impedance: Return Loss: T ransHybrid Loss: Longitudinal Balance: Frequency Response: Idle Channel Noise: PCM Encoding/Decoding: DC Supervisory Range: 23 mAmp nom inal 20 mAmp minimum –7.
Een belangrijk punt na aankoop van elk apparaat ADTRAN FXS/DPO/PLAR 1109403L2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ADTRAN FXS/DPO/PLAR 1109403L2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ADTRAN FXS/DPO/PLAR 1109403L2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ADTRAN FXS/DPO/PLAR 1109403L2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ADTRAN FXS/DPO/PLAR 1109403L2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ADTRAN FXS/DPO/PLAR 1109403L2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ADTRAN FXS/DPO/PLAR 1109403L2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ADTRAN FXS/DPO/PLAR 1109403L2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.