NLS-FM208 Fixed T ype Industrial level User Guide Latest:20081015.
nlscan.com Page II 目录 About This Reference 1 Introducation 1 Graphic Emphasis 1 Chapter Description 1 Getting Start 2 Introducation 2 Familiar with FM200 3 Unpacking 3 Outline 3 Data Interface 4 C.
nlscan.com Page III USB Interface 22 Introduction 22 USB HID-KBW 23 USB Country Keyboard T ypes 24 USB Country Keyboard T ypes 25 Unknown Characters, Beep 26 Function Key Mapping 28 ASCII Function Key.
nlscan.com Page IV 2 Digits Addenda Code 48 5 Digits Addenda Code 48 UPC-E 49 Load Factory Default 49 Read/Abort UPC-E 49 Check Byte 49 T ransmit First ‘ 0 ’ Selections 51 Extend T o UPC-A Selecti.
nlscan.com Page V Read/Abort UCC/EAN-128 74 PDF417 75 Load Factory Default 75 Read/Abort PDF417 75 Select Message Length 76 QR Code 77 Load Factory Default 77 Read/Abort QR Code 77 Select Message Leng.
nlscan.com Page VI Message Intersect & Pack 98 Introducation 98 Message Intersect 99 introduction 99 1D, Program Intersect Option 100 How to clear a certain 1D barcode Intersection Setting? 100 Me.
nlscan.com Page 1 Introducation This product reference introduces a Newland Auto-ID Image product — NLS- FM208 (ab. " FM208"). Graphic Emphasis TOOL, facilitate use of the manual A TTENTION, be aware & read through E.g., help understand a certain operation.
nlscan.com Page 2 Introducation FM208 is an omnidirectional Imager to capture, decode and transfer 1D & 2D barcode. Newland Auto-ID patented UIMG™ technology ensure its fast and accurate performance, and thus provide the best value. It works at hand-held and hands-free modes in a stand.
Getting Start nlscan.com Page 3 Outline Familiar with FM200 Reading W indow T rigger Indicator Unpacking Unpack FM200 and accessories. Check with the packing list to make sure that there is none damaged or missing. If any , please keep the original package and contact your supplier for services.
nlscan.com Page 4 Getting Start Data Interface Data Interface Familiar with FM200.
Getting Start nlscan.com Page 5 Communication Ports FM200, An imager , Must connect with a Host to perform. A Host can be PC, POS. Or any intelligent terminal with supported communication ports. US 1. B : USB port on host : RS23 2. 2 : RS232 port on host : Please check available ports to order appropriate cable fitted.
nlscan.com Page 6 Getting Start Connect FM200 & Host Install USB Cable Insert USB Cable (RJ45 male head) into cable slot (HR200); 1. Insert USB Cable (USB male head) into USB slot (Host female slot); 2. Switch ON and perform; 3. Y ou may need to install driver into the host to perform; See USB Interface 4.
Getting Start nlscan.com Page 7 Install RS232 Cable Connect FM200 & Host Insert RS232 cable (RJ 45 male head) into cable slot (HR200); 1. Insert RS232 cable (RS232 male head) into RS232 slot (Host female slot); 2. Connect RS232 cable and the mains with power adapter; 3.
nlscan.com Page 8 Getting Start Power On Connect FM200 and Host. FM200 will power on and in "Idle" status (factory default). Communication Programming, Reading and User Preference Programming can be progressed when power ON.
Getting Start nlscan.com Page 9 Programming Outline Introducation There are 3 ways to program user options: Code Programming: special encoded barcodes to work on "read & set options" base; 1. Command Programming: a ASCII string, the Imager received from data cable as commands to set options; 2.
nlscan.com Page 10 Getting Start Programming Outline Command Programming The Programming Command (Pro CMD) pairs a unique Programming Code. Sending commands to the Imager is identical with Code Programming. A full command is formed by [Start Symbol "nls" + Pro CMD = Parameters].
Getting Start nlscan.com Page 1 1 Reading The “ Sensor Mode ” or “ Continuous Mode ” should be selected. See “ Reading Mode ” for details. Because FM208 does not have a manual trigger , and it is a fix mount reader . Mobile phone screen should be facing the scan window for the optimum reading stance.
nlscan.com Page 12 Getting Start Code Programming ON Code Programming OFF T ools Illumination LED lighting up barcodes is used to capture better images.
Getting Start nlscan.com Page 13 Code Programming ON Code Programming OFF T ools Aiming ** Aim W ink 【 Pro CMD : 0201000 】 Smart Aim 【 Pro CMD : 0201030 】 Aim Keep ON 【 Pro CMD : 0201010 】 Aim OFF 【 Pro CMD : 0201020 】 Aiming LED focusing with a cross is used to allocate the Optimum Reading Stance.
nlscan.com Page 14 Getting Start Code Programming ON Code Programming OFF T ools Reading Mode Mode Selection Hand-held Mode: press and keep holding the trigger to read.
Getting Start nlscan.com Page 15 Code Programming ON Code Programming OFF T ools Sensor Mode Sensitivity Sensitivity is the extent to which the engine responds environmental lamination change. Sensitivity value is 0~20(including). The lower the sensitivity value chosen, the higher sensitivity will be.
nlscan.com Page 16 Getting Start mm 52.8 mm 52.8 17.6 17.6 35.2 35.2 0 60 100 140 180 220 27° Reading Stance is defined as the distance between the Imager front and an object (barcode). It af fects image capturing area and image quality , and thus affects reading performance.
Getting Start nlscan.com Page 17 Code Programming ON Code Programming OFF T ools “ Constrain Multi-reading ” is used to avoid mis-reading on the same barcode (the same format and message) in a multi-reading timeout.
nlscan.com Page 18 Getting Start Code Programming ON Code Programming OFF T ools Factory Default Read “ Load All Factory Default ” to reset all user option to factory default. Applicable Circumstance: User options programming error lead to reading malfunction 1.
Getting Start nlscan.com Page 19 Beep Denotation Beep Denotation low-higher-higher -higher Power ON completed 1 beep successful read of an ordinary barcode 2 beeps successful read of an programming ba.
nlscan.com Page 20 Getting Start Code Programming ON Code Programming OFF T ools “ Send Sys Info ” , the engine sends system information to the Host immediately . “ Power ON, Send Sys Info ” , the engine sends system information to the Host right after Power ON.
Getting Start nlscan.com Page 21 Maintenance Keep the scan window clean is the only work needs to do. Improper maintenance will avoid limited warranty . » A void rough object damage or scratch the window . » Use brush to remove the stain. » Use soft cloth (cloth of glasses) to clean.
nlscan.com Page 23 USB Interface Introduction When using a USB connection, the default protocol is USB DataPipe. USB DataPipe is a Newland Auto-ID Co., Ltd. developed protocol. The DataPipe driver should be installed on the Host. It supports data transmission and user preference programming.
USB Interface nlscan.com Page 24 Code Programming ON Code Programming OFF T ools USB connection (no driver needed) supports simulating the Imager transmission to be a USB keyboard input. The Host receives keystrokes of the virtual keyboard. It works in “ Plug and Play ” base.
nlscan.com Page 25 USB Interface Code Programming ON Code Programming OFF T ools USB Country Keyboard T ypes The keyboard arrangements and country codes vary in different countries. Refer country codes to » the table “ USB Country Keyboard T ypes ” .
USB Interface nlscan.com Page 26 USB Country Keyboard T ypes Country/Language Number Country/Language Number U.S. 0 Netherlands(Dutch) 14 Belgium 1 Norway 15 Brazil 2 Poland 16 Canada(French) 3 Portug.
nlscan.com Page 27 USB Interface Code Programming ON Code Programming OFF T ools Unknown Characters, Beep HID-KBW deams an unknown character to be a character is not included in a country keyboard type. It may not be able to allocate and send a keystroke, thus lead to an error beep.
USB Interface nlscan.com Page 28 Code Programming ON Code Programming OFF T ools USB HID-KBW Emulate AL T + keypad When enabled, all characters are sent as ASCII sequences over the numeric keypad: “.
nlscan.com Page 29 USB Interface Code Programming ON Code Programming OFF T ools Function Key Mapping When enabled, function characters (0x00~0x1F) are sent as ASCII sequences over the numeric keypad.
USB Interface nlscan.com Page 30 ASCII Function Key Mapping T able ASCII(HEX) Function key ASCII(HEX) Function Key 00 2 10 P 01 A 1 1 Q 02 B 12 R 03 C 13 S 04 D 14 T 05 E 15 U 06 F 16 V 07 G 17 W 08 H 18 X 09 I 19 Y 0A J 1A Z 0B K 1B [ 0C L 1C 0D M 1D ] 0E N 1E 6 0F O 1F .
nlscan.com Page 31 USB Interface Code Programming ON Code Programming OFF T ools Keystroke Delay This parameter sets the delay , in milliseconds, between emulated keystrokes. Scan programming code below to increase the delay when the Host require a slower transmission of data.
USB Interface nlscan.com Page 32 Code Programming ON Code Programming OFF T ools USB HID-KBW Convert Case The Imager converts all barcode messages to the selected case.
nlscan.com Page 33 USB Interface Code Programming ON Code Programming OFF T ools Emulate Numeric Keypad Read “ Emulate Numeric Keypad ” to enable the function. “ 0~9./*-+ ” of the barcode message will be emulated as keystrokes on numeric keypad.
USB Interface nlscan.com Page 34 Code Programming ON Code Programming OFF T ools USB DataPipe This protocol is defined by Newland Auto-ID. A driver has to be installed before using this protocol to communicate with reader , The advantage of using this protocol is the speedy data transmission.
nlscan.com Page 35 USB Interface Code Programming ON Code Programming OFF T ools USB V isual RS232 When the USB port is connected to host RS232 port in order to receive data from scanner , the model of imitating USB-to-RS232 has to be chosen.
nlscan.com Page 36 RS232 Interface Inteuduction Under RS232 connection, the engine and the Host should use the same communication parameters: baud rate, parity check, data bits select and stop bits select.
RS232 Interface nlscan.com Page 37 Code Programming ON Code Programming OFF T ools Baud Rate Baud rate is the bits transmitted per second (8 bits per bytes).
nlscan.com Page 38 RS232 Interface Code Programming ON Code Programming OFF T ools Parity check options should be the same on the engine and the Host. ** NO Check 【 Pro CMD : 0101000 】 Even Chec.
RS232 Interface nlscan.com Page 39 Code Programming ON Code Programming OFF T ools Data Bits T ransmitted Select data bits transmitted to be 5, 6, 7 and 8.
nlscan.com Page 40 RS232 Interface Code Programming ON Code Programming OFF T ools Stop bit follows every byte to indicate the end of transmission and the start of the next transmission.
nlscan.com Page 41 Symbologies Introduction This chapter describes symbology features and provides the programming barcodes for selecting these features.
Symbologies nlscan.com Page 42 Code Programming ON Code Programming OFF T ools General Options Prohibit Reading All Prohibit Reading All = allow reading programming codes only . Prohibit Reading All 【 Pro CMD : 0001010 】 Allow Reading All Allow Reading All = enable to read all symbologies and programming codes.
Symbologies nlscan.com Page 43 Code Programming ON Code Programming OFF T ools Code 128 Load Factory Default Read to load Code 128 factory default. ** Load Code 128 Factory Default 【 Pro CMD : 040.
Symbologies nlscan.com Page 44 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 45 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load UCC/EAN-8 factory default. ** Load UCC/EAN-8Factory Default 【 Pro CMD : 0401000 】.
Symbologies nlscan.com Page 46 Code Programming ON Code Programming OFF T ools "Read 2 Digits Addenda" — read an ordinary code and 2 digits addenda code "Read 5 Digits Addenda" .
nlscan.com Page 47 Symbologies Code Programming ON Code Programming OFF T ools UCC/EAN-8 EAN-8 expand to EAN-13 Expand EAN-8 to EAN-13, by adding 5 bytes of “ 0 ” to the left, and then transmit.
Symbologies nlscan.com Page 48 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load EAN-13 factory default. ** Load EAN-13 Factory Default 【 Pro CMD : 0402000 】 ** R.
Symbologies nlscan.com Page 49 Code Programming ON Code Programming OFF T ools "Read 2 Digits Addenda" — read an ordinary code and 2 digits addenda code "Read 5 Digits Addenda" .
Symbologies nlscan.com Page 50 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load UPC-E factory default. ** UPC-E Load Code 128 Factory Default 【 Pro CMD : 0403000 .
Symbologies nlscan.com Page 51 Code Programming ON Code Programming OFF T ools 5 Digits Addenda Code Picture bellow shows an ordinary code with a 5 digits addenda code. The left one with blue circle is an ordinary code. The right one with red circle is the 5 digits addenda code.
Symbologies nlscan.com Page 52 Code Programming ON Code Programming OFF T ools T ransmit First ‘ 0 ’ Selections The first character of UPC-E is a system digit.
Symbologies nlscan.com Page 53 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load UPC-A factory default. **Load UPC-A Factory Default 【 Pro CMD : 0404000 】 Read/Ab.
Symbologies nlscan.com Page 54 Code Programming ON Code Programming OFF T ools "Read 2 Digits Addenda" — read an ordinary code and 2 digits addenda code "Read 5 Digits Addenda" .
nlscan.com Page 55 Symbologies Code Programming ON Code Programming OFF T ools UPC-A T ransmit Selections UPC-A the first byte (very left one) is default “ 0 ” ** No T ransmit “ 0 ” 【 Pro CMD : 0404090 】 T ransmit “ 0 ” 【 Pro CMD : 0404100 】 UPC-A has the default “ 0 ” but it is not printed out, not like UPC-E.
Symbologies nlscan.com Page 56 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load Interleaved 2 of 5 factory default. ** Load Interleaved 2 of 5 Factory Default 【 Pro .
Symbologies nlscan.com Page 57 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 58 Code Programming ON Code Programming OFF T ools ** NO Check, T ransmit All 【 Pro CMD : 0405050 】 Check, T ransmit No Check 【 Pro CMD : 0405060 】 Check, T ransmit All 【 Pro CMD : 0405070 】 Check Byte Interleaved 2 of 5 may include Check Byte (not compulsory) following its barcode messages.
nlscan.com Page 59 Symbologies Code Programming ON Code Programming OFF T ools Interleaved 2 of 5 Fixed Length Selection Program the engine to read fixed length or fixed length area Interleaved 2 of 5. Command programming use 3 decimal digits to define length value.
Symbologies nlscan.com Page 60 Code Programming ON Code Programming OFF T ools ITF-14 ITF-14 is a fixed length 14 bytes Interleaved 2 of 5 barcode with parity check. For factory default, the engine deems ITF-14 as ordinary Interleaved 2 of 5. And selections of Interleaved 2 of 5 will affect ITF-14.
nlscan.com Page 61 Symbologies Code Programming ON Code Programming OFF T ools ITF-6 ITF-6 is a fixed length 6 bytes Interleaved 2 of 5 barcode with parity check. As it to user selections, factory default, the engine deems ITF-6 as ordinary Interleaved 2 of 5.
Symbologies nlscan.com Page 62 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load China Post 25 factory default. ** Load China Post25 Factory Default 【 Pro CMD : 040.
Symbologies nlscan.com Page 63 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 64 Code Programming ON Code Programming OFF T ools China Post 25 Check Byte CHINA POST 25 may include Check Byte (not compulsory) following its barcode message.
Symbologies nlscan.com Page 65 Code Programming ON Code Programming OFF T ools Code 39 Load Factory Default Code 39 Read to load Code 39 factory default.
Symbologies nlscan.com Page 66 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 67 Code Programming ON Code Programming OFF T ools Code 39 Check Byte Code 39 may include Check Byte (not compulsory) following its barcode message.
Symbologies nlscan.com Page 68 Code Programming ON Code Programming OFF T ools Code 39 Decode ASCII Code 39 can include full ASCII characters. For factory default, the engine enabled to decode partial of them. Read “ Enable Full ASCII decode ” to select full ASCII functions.
Symbologies nlscan.com Page 69 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load Codabar factory default. ** Load Codabar Factory Default 【 Pro CMD : 0409000 】 Re.
Symbologies nlscan.com Page 70 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 71 Code Programming ON Code Programming OFF T ools Read "Check, T ransmit NO Check", only transmit barcode message. If barcode message length is less than Min Message Length, this will lead to error beep. E.g. : Read a 4 bytes (include Check Byte) Codabar .
Symbologies nlscan.com Page 72 Code Programming ON Code Programming OFF T ools Code 93 Load Factory Default Read to load Code 93 factory default. ** Load Code 93 Factory Default 【 Pro CMD : 041000.
Symbologies nlscan.com Page 73 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 74 Code Programming ON Code Programming OFF T ools Read “ No T ransmit Check ” . If barcode message length is less than Min Message length, this will lead to error beep. E.g.: Read a 4 bytes (include Check Byte) Code 93.
Symbologies nlscan.com Page 75 Code Programming ON Code Programming OFF T ools UCC/EAN-128 Load Factory Default Read to load UCC/EAN-128 factory default.
Symbologies nlscan.com Page 76 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load PDF417 factory default. ** Load PDF417 Factory Default 【 Pro CMD : 0501000 】 Read.
Symbologies nlscan.com Page 77 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 78 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load QR Code factory default. ** Load QR Code Factory Default 【 Pro CMD : 0502000 】 Re.
Symbologies nlscan.com Page 79 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 80 Code Programming ON Code Programming OFF T ools QR T win Code QR twin code is 2 QR barcodes paralleled vertically or horizontally . There are 3 options for reading QR Code: Single QR Only: Select to read only one QR Code, and abort twin code.
Symbologies nlscan.com Page 81 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load Aztec Code factory default. ** Load Aztec Code Factory Default 【 Pro CMD : 0503000 .
Symbologies nlscan.com Page 82 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
nlscan.com Page 83 Symbologies Code Programming ON Code Programming OFF T ools Aztec Code Multi-Barcode Processing feature The Aztec Codes can be lined up horizontal or vertical. The scanner processes multi-Barcodes simultaneously . There are 3 options can be chosen: Model 1: Disable multi-Barcodes feature.
Symbologies nlscan.com Page 84 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load Data Matrix factory default. ** Load Data Matrix Factory Default 【 Pro CMD : 050400.
Symbologies nlscan.com Page 85 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
Symbologies nlscan.com Page 86 Code Programming ON Code Programming OFF T ools Data Matrix T win Code Data Matrix twin code is 2 Data Matrix barcodes paralleled vertically or horizontally . There are 3 options for reading Data Matrix: Single Data Matrix Only: select to read only one Data Matrix, and abort twin code.
Symbologies nlscan.com Page 87 Code Programming ON Code Programming OFF T ools Load Factory Default Read to load Chinese-Sensible Code factory default.
Symbologies nlscan.com Page 88 Code Programming ON Code Programming OFF T ools "Code Programming ON" 1. "Select Min Message Length" 2. Digit code "8", see Digit Code 3. "Save Programming", see Digit Code 4. "Select Max Message Length" 5.
nlscan.com Page 89 OCR Selections Inrtuducation OCR (Optical Character Recognition) is the technology that capture image of printed information, and recognize the image to editable characters. The engine satisfy OCR B standard and support specific typeface.
nlscan.com Page 90 Prefix/Suf fix Intruducation 1D barcode message could contain digits, letters and symbols, etc. 2D barcode message could contain more data such as Chinese characters and other 2 bytes characters. Practically , barcode message is insufficient for usage.
Prefix/Suf fix nlscan.com Page 91 Code Programming ON Code Programming OFF T ools General Programming Prohibit or Allow Prefix/Suf fix Prohibit All Prefix/Suf fix: T ransmit barcode message with no Prefix/Suf fix. Allow All Prefix/Suf fix: Allow appending CodeID prefix, AIM prefix, User prefix, User suffix and Stop suffix to the barcode message.
nlscan.com Page 92 Prefix/Suf fix Code Programming ON Code Programming OFF T ools User Prefix Prohibit or Allow User Prefix User Prefix append to the left of barcode message. For example, program “ AB ” as user prefix, and the barcode message is “ 123 ” .
Prefix/Suf fix nlscan.com Page 93 Code Programming ON Code Programming OFF T ools AIM Prefix AIM (Automatic Identification Manufactures) defines AIM prefix for many standard barcode formats. There are 3 types of AIM prefix. Character Mode: Append AIM prefix.
nlscan.com Page 94 Prefix/Suf fix Code Programming ON Code Programming OFF T ools Code ID Prefix Apart from AIM prefix, Code ID prefix can be used to denote barcode format and can be customized. The Code ID prefix MUST be 1 visible English letter , only .
Prefix/Suf fix nlscan.com Page 95 Code Programming ON Code Programming OFF T ools Code ID Prefix Modify Code ID Modify Code ID steps: 1. “ Code Programming ON ” 2. Read the programming code to enable modifying Code ID for symbologies 3. Read the hex of a visible English letter .
nlscan.com Page 96 Prefix/Suf fix Code Programming ON Code Programming OFF T ools Modify EAN-13 【 Pro CMD : 0004050 】 Modify Interleaved 2 of 5 【 Pro CMD : 0004080 】 Modify Codabar 【 Pro.
Prefix/Suf fix nlscan.com Page 97 Code Programming ON Code Programming OFF T ools 8.4 User Suf fix Prohibit or Allow User Suf fix User suffix append to the right of barcode message. For example, program “ AB ” as user suffix, and the barcode message is “ 123 ” .
nlscan.com Page 98 Prefix/Suf fix Code Programming ON Code Programming OFF T ools Prohibit or Allow Stop Suf fix “ Stop Suffix ” is the termination for a string of barcode messages. It can not be formatted like other suffix and prefix. It is fixed to the right and the very end of a barcode transmission.
nlscan.com Page 99 Message Intersect & Pack Introducation This chapter introduces Message Intersect & Pack. Message intersection only af fects plain barcode message.
Message Intersect & Pack nlscan.com Page 100 Code Programming ON Code Programming OFF T ools introduction Intersection Rule No.1: only affects selected symbologies ’ plain barcode message. Note that » one intersection option affects all barcodes of the barcode format.
nlscan.com Page 101 Message Intersect & Pack 1D, Program Intersect Option A command input consists of 3 decimals. The first input is for barcode format; Refer to “ Symbologies ID Number ” . The second input is for intersecting direction; “ 000 ” denotes ascending (left to right) and “ 001 ” denotes descending.
Message Intersect & Pack nlscan.com Page 102 Message Intersect 2D, Program Intersect Option A command input consists of 3 or 6 decimals. The first input is for barcode format; Refer to “ Symbologies ID Number ” . The second input is for intersecting direction; “ 000 ” denotes ascending and “ 001 ” denotes descending.
nlscan.com Page 103 Message Intersect & Pack Symbologies ID Number : Symbologies ID Number Code 128 002 UCC/EAN128 003 EAN-8 004 EAN-13 005 UPC-E 006 UPC-A 007 Interleaved 2 OF 5 008 China Post2.
Message Intersect & Pack nlscan.com Page 104 Code Programming ON Code Programming OFF T ools Introduction Data Pack is for the special requirements of barcode message. There are 3 types of data pack. Data pack affects all data formats, in that be sure to load the default “ Disable Pack ” if pack is not required.
nlscan.com Page 105 Message Intersect & Pack Code Programming ON Code Programming OFF T ools ESC_Bank Pack ESC_BANK pack format: [STX] + [DA T A] + [ETX] + [BCC] STX : 0x02 。 » DA T A : Barcode message » ETX : 0x03 。 » BCC : Parity byte » The algorithm: 1.
Message Intersect & Pack nlscan.com Page 106 Code Programming ON Code Programming OFF T ools Message Pack ESC_AddLen Pack ESC_AddLen pack format: [STX] +[LEN] + [DA T A] + [ETX] + [BCC] STX : 0x02 。 LEN : Barcode message length is expressed by 4 bytes.
nlscan.com Page 107 Batch Programming Itruducation Batch Programming can integrate a programming sequence into one barcode. Batch Programming Rules: 1. Sub-command is in this format: Programming Command + Parameters 2. Sub-commands are terminated by semicolons.
nlscan.com Page 108 Appendix Digit Code It is must to be read save after read digit code. 0 【 Pro CMD : 0000000 】 3 【 Pro CMD : 0000030 】 6 【 Pro CMD : 0000060 】 9 【 Pro CMD : 00.
nlscan.com Page 109 Appendix Code Programming ON Code Programming OFF T ools Save and Abort In order to save the data received “ Save ” has to be read after data transition completed. If error occurs when reading data, the wrong data can be deleted and the setting up can be done again.
Een belangrijk punt na aankoop van elk apparaat Newland FM208 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Newland FM208 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Newland FM208 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Newland FM208 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Newland FM208 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Newland FM208 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Newland FM208 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Newland FM208 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.