NL
NEC logo
Officiële handleiding

NEC ND-70895 (E)

106 pagina's·1.4 MB·Seniorentelefoon·PDF·EN
NEC ND-70895 (E)
Inhoudsopgave 93 secties Table of Contents · List of Figures · List of Tables · CHAPTER 1 INTRODUCTION · … TonenVerbergen
Table of Contentsp.5List of Figuresp.8List of Tablesp.9CHAPTER 1 INTRODUCTIONp.111. Generalp.112. How to Follow the Manualp.112.1 Configuration of This Manualp.112.2 Related Reference Manualp.12CHAPTER 2 SYSTEM OUTLINEp.131. Generalp.132. System Outlinep.142.1 OAI (Open Application Interface) Systemp.142.2 Software Structure in the OAI Systemp.142.2.1 Facilitiesp.162.2.2 Join of Facilities and Applicationp.232.2.3 Cope of Application in changeover of CPU Systemp.233. System Configurationp.244. Interface with External Computerp.274.1 Conditions for Interface with External Computerp.27CHAPTER 3 INSTALLATION PROCEDUREp.291. Generalp.292. Cable Connections with External Computerp.302.1 Cable Connections between OAI System and External Computerp.303. OAI Software Installationp.314. Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMXp.334.1 Up Grading Procedurep.33CHAPTER 4 COMMANDSp.351. Generalp.352. Configuration of Commands for OAI Systemp.362.1 Configuration of Commandsp.363. Commandsp.373.1 List of Commandsp.373.2 Outline of Commands for OAI Systemp.383.3 Items to Be Explained by Each Commandp.38AADTp.39ACNOp.41AKYDp.43AMNOp.44AOACp.46AOKCp.48ASPAp.52ASYDp.53DFLNp.63ASYDNp.64ASYDLp.66CHAPTER 5 OFFICE DATA DESIGNp.691. Generalp.692. Procedure for Setting Basic Office Data for OAI Systemp.702.1 Data for OAI Systemp.702.2 Data for OAI Terminalp.713. Procedure for Setting Office Data for OAI Servicesp.723.1 Switch Control Facility (SCF)p.723.1.1 Functional Outlinep.723.1.2 Using Conditionsp.733.1.3 Data Programmingp.753.2 Call ID Notification (SMFN for ISDN)p.763.2.1 Functional Outlinep.763.2.2 Using Conditionsp.763.2.3 Data Programmingp.773.3 MWL Control (SSF) STEP-1p.783.3.1 Functional Outlinep.783.3.2 Using Conditionsp.793.3.3 Data Programmingp.813.4 TCP/IP Address (Assignment from MAT)p.823.4.1 Functional Outlinep.823.4.2 Using Conditionsp.823.4.3 Data Programmingp.833.5 Name Displayp.843.5.1 Functional Outlinep.843.5.2 Using Conditionsp.843.5.3 Data Programming (Set up from User’s Application)p.853.6 Inter Node Name Displayp.863.6.1 Functional Outlinep.863.6.2 Using Conditionsp.863.6.3 Data Programming (Set up from User’s Application)p.883.7 OAI Fusionp.893.7.1 OAI Terminal Anywherep.893.7.2 Multiple IPsp.913.7.3 Example of Use of Facility on Fusion Networkp.95CHAPTER 6 MAINTENANCEp.971. Generalp.972. Maintenancep.982.1 Routine Maintenancep.982.1.1 System Messages and Lamp Indications on TOPUp.983. System Messagesp.993.1 Outlinep.993.2 Message Detail Datap.1003.2.1 Message Detail Data of System Message “4-R”p.1003.2.2 Message Detail Data of System Message “26-V”p.1014. Fault Diagnosisp.1024.1 Generalp.1024.2 Diagnosis from System Messagesp.1034.2.1 TCP/IP Link Failurep.104
Page 1 of the NEC ND-70895 (E) user manual
Pagina 1 · klik om te vergroten
Pagina 1
NEC ND-70895 (E) diagram (page 1)
Afb. 1
Page 2 of the NEC ND-70895 (E) user manual — LIABILITY DISCLAIMER
Pagina 2 · klik om te vergroten
Pagina 2

LIABILITY DISCLAIMER

NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice.

NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc.

NEAX and Dterm are registered trademarks of NEC Corporation.

All other brand or product names are or may be trademarks or registered trademarks of, and are used to identify products or services of, their respective owners.

MS-DOS and Microsoft are registered trademarks of Microsoft Corporation. Microsoft Windows 95 and Windows NT are trademarks of Microsoft Corporation.

NEC America, Inc.

Printed in the U.S.A

Copyright 2000

Page 3 of the NEC ND-70895 (E) user manual
Pagina 3 · klik om te vergroten
Pagina 3
NEC ND-70895 (E) diagram (page 3)
Afb. 2
ISSUE 1ISSUE 2ISSUE 3ISSUE 4 DATESEPTEMBER, 2000DATEDATEDATE ISSUE 5ISSUE 6ISSUE 7ISSUE 8 DATEDATEDATEDATE NEAX2400 IMX OAI System Manual Issue Revision Sheet 1/2 ND-70895 (E) ISSUE 1
Page 4 of the NEC ND-70895 (E) user manual
Pagina 4 · klik om te vergroten
Pagina 4
NEC ND-70895 (E) diagram (page 4)
Afb. 3

1 2 3 4 5 6 7 8 PAGE No.

ISSUE 1ISSUE 2ISSUE 3ISSUE 4 DATESEPTEMBER, 2000DATEDATEDATE ISSUE 5ISSUE 6ISSUE 7ISSUE 8 DATEDATEDATEDATE NEAX2400 IMX OAI System Manual Issue Revision Sheet 2/2 ND-70895 (E) ISSUE 1
Page 5 of the NEC ND-70895 (E) user manual — Inhoudsopgave
Pagina 5 · Inhoud
Inhoud

Inhoud

Table of Contentsp.5List of Figuresp.8List of Tablesp.9CHAPTER 1 INTRODUCTIONp.111. Generalp.112. How to Follow the Manualp.112.1 Configuration of This Manualp.112.2 Related Reference Manualp.12CHAPTER 2 SYSTEM OUTLINEp.131. Generalp.132. System Outlinep.142.1 OAI (Open Application Interface) Systemp.142.2 Software Structure in the OAI Systemp.142.2.1 Facilitiesp.162.2.2 Join of Facilities and Applicationp.232.2.3 Cope of Application in changeover of CPU Systemp.233. System Configurationp.244. Interface with External Computerp.274.1 Conditions for Interface with External Computerp.27CHAPTER 3 INSTALLATION PROCEDUREp.291. Generalp.292. Cable Connections with External Computerp.302.1 Cable Connections between OAI System and External Computerp.303. OAI Software Installationp.314. Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMXp.334.1 Up Grading Procedurep.33CHAPTER 4 COMMANDSp.351. Generalp.352. Configuration of Commands for OAI Systemp.362.1 Configuration of Commandsp.363. Commandsp.373.1 List of Commandsp.373.2 Outline of Commands for OAI Systemp.383.3 Items to Be Explained by Each Commandp.38AADTp.39ACNOp.41AKYDp.43AMNOp.44AOACp.46AOKCp.48ASPAp.52ASYDp.53DFLNp.63ASYDNp.64ASYDLp.66CHAPTER 5 OFFICE DATA DESIGNp.691. Generalp.692. Procedure for Setting Basic Office Data for OAI Systemp.702.1 Data for OAI Systemp.702.2 Data for OAI Terminalp.713. Procedure for Setting Office Data for OAI Servicesp.723.1 Switch Control Facility (SCF)p.723.1.1 Functional Outlinep.723.1.2 Using Conditionsp.733.1.3 Data Programmingp.753.2 Call ID Notification (SMFN for ISDN)p.763.2.1 Functional Outlinep.763.2.2 Using Conditionsp.763.2.3 Data Programmingp.773.3 MWL Control (SSF) STEP-1p.783.3.1 Functional Outlinep.783.3.2 Using Conditionsp.793.3.3 Data Programmingp.813.4 TCP/IP Address (Assignment from MAT)p.823.4.1 Functional Outlinep.823.4.2 Using Conditionsp.823.4.3 Data Programmingp.833.5 Name Displayp.843.5.1 Functional Outlinep.843.5.2 Using Conditionsp.843.5.3 Data Programming (Set up from User’s Application)p.853.6 Inter Node Name Displayp.863.6.1 Functional Outlinep.863.6.2 Using Conditionsp.863.6.3 Data Programming (Set up from User’s Application)p.883.7 OAI Fusionp.893.7.1 OAI Terminal Anywherep.893.7.2 Multiple IPsp.913.7.3 Example of Use of Facility on Fusion Networkp.95CHAPTER 6 MAINTENANCEp.971. Generalp.972. Maintenancep.982.1 Routine Maintenancep.982.1.1 System Messages and Lamp Indications on TOPUp.983. System Messagesp.993.1 Outlinep.993.2 Message Detail Datap.1003.2.1 Message Detail Data of System Message “4-R”p.1003.2.2 Message Detail Data of System Message “26-V”p.1014. Fault Diagnosisp.1024.1 Generalp.1024.2 Diagnosis from System Messagesp.1034.2.1 TCP/IP Link Failurep.104
Page 8 of the NEC ND-70895 (E) user manual — ND-70895 (E) LIST OF FIGURES
Pagina 8 · klik om te vergroten
Pagina 8

LIST OF FIGURES

Figure 2-1 Software Structure in the OAI System 5 Figure 2-2 Concept of MSF 6 Figure 2-3 Concept of TMF 7 Figure 2-4 Concept of ETF 7 Figure 2-5 Concept of ACF 8 Figure 2-6 Concept of FLF 8 Figure 2-7 Concept of TCF 9 Figure 2-8 Concept of KTF 9 Figure 2-9 Concept of NTF 10 Figure 2-10 Concept of SCF 10 Figure 2-11 Concept of RCF 11 Figure 2-12 Concept of MRF 11 Figure 2-13 Concept of ATF 12 Figure 2-14 IP Single System Configuration 15 Figure 2-15 IP Dual System Configuration 16 Figure 3-1 Cable Connections Between OAI System and External Computer 20 Figure 4-1 Configuration of Commands of the NEAX2400 IMX OAI System 26 Figure 4-2 Interrelation among OAI System Commands 28 Figure 5-1 Network Configuration of OAI systems 82 Figure 6-1 Flow of Maintenance Works 87 Figure 6-2 Flow of Fault Repair 92 Figure 6-3 Flow of Diagnosis out of System Messages 93

ND-70895 (E) LIST OF FIGURES

Page iv Revision 1.0

Figure Title Page

Page 9 of the NEC ND-70895 (E) user manual — ND-70895 (E) LIST OF TABLES
Pagina 9 · klik om te vergroten
Pagina 9

LIST OF TABLES

Table 1-1 Configuration of This Manual 1 Table 1-2 Related Reference Manual 2 Table 2-1 Interface Conditions of the Circuit Card 17 Table 4-1 OAI System Command Table List 27 Table 4-2 Supplementary Service Codes 42 Table 5-1 OAI Software and System Data 83 Table 6-1 Relationship between System Messages and Alarm Lamps on TOPU 88 Table 6-2 System Messages of OAI System 89 Table 6-3 Error Code 90 Table 6-4 Repairing Procedure for TCP/IP Link Failure (Message “4-R”) 94 Table 6-5 Repairing Procedure for TCP/IP Link Failure (Message “26-V”) 94

ND-70895 (E) LIST OF TABLES

Page v Revision 1.0

Table Title Page

Page 10 of the NEC ND-70895 (E) user manual — List of Tables
Pagina 10 · klik om te vergroten
Pagina 10

This page is for your notes.

LIST OF TABLES ND-70895 (E) Page vi Revision 1.0

Page 11 of the NEC ND-70895 (E) user manual — 2. How to Follow the Manual
Pagina 11 · klik om te vergroten
Pagina 11

CHAPTER 1 INTRODUCTION

1. General

This manual describes the outline, installation procedure/installation tests, and various phases of maintenance work of an OAI (Open Application Interface) system which realizes the NEAX2400 IMX and a computer system.

2. How to Follow the Manual

2.1 Configuration of This Manual

Configuration of this manual is shown in Table 1-1.

Table 1-1 Configuration of This Manual

CHAPTERTITLECONTENTS 2SYSTEM OUTLINEThis chapter describes the concept, function and configuration of the NEAX2400 IMX OAI System 3INSTALLATION PROCEDUREThis chapter describes the installation procedure for NEAX2400 IMX OAI System 4COMMANDSThis chapter describes the commands that are used in NEAX2400 IMX OAI System 5OFFICE DATA DESIGNThis chapter describes the procedure for setting the office data required in NEAX2400 IMX OAI System 6MAINTENANCEThis chapter describes the maintenance, fault diagnosis and fault repair procedure of NEAX2400 IMX OAI System
Page 12 of the NEC ND-70895 (E) user manual — 2.2 Related Reference Manual
Pagina 12 · klik om te vergroten
Pagina 12

INTRODUCTION How to Follow the Manual

2.2 Related Reference Manual

The installation tasks for the NEAX2400 IMX OAI System consist of those related to the NEAX2400 IMX system and those related to the OAI functions. Since this manual describes the tasks pertaining to the OAI functions, it must be used together with the following manuals that describe tasks pertaining to the NEAX2400 IMX itself when performing tasks pertaining to the NEAX2400 IMX OAI System.

Table 1-2 Related Reference Manual

MANUALS FOR NEAX2400 IMXRELATIONSHIP WITH THIS MANUAL Installation ManualWhen performing installation and installation tests of the NEAX2400 IMX OAI System, these manuals are to be used together with Chapter 3, "INSTALLATION PROCEDURE" and also with “Circuit Card Manual”. Feature Programming Manual System Operations and Maintenance ManualWhen performing maintenance jobs on the NEAX2400 IMX OAI System, this manual is to be used together with Chapter 6, "MAINTENANCE" of this manual. Office Data SpecificationWhen performing installation tests and maintenance jobs on the NEAX2400 IMX OAI System, this manual is to be used together with Chapter 4, "COMMANDS" of this manual.
Page 13 of the NEC ND-70895 (E) user manual — CHAPTER 2 SYSTEM OUTLINE
Pagina 13 · klik om te vergroten
Pagina 13

CHAPTER 2 SYSTEM OUTLINE

1. General

This chapter describes the concept, functions, and configuration of the NEAX2400 IMX OAI System. Before performing installation and/or maintenance of the NEAX2400 IMX OAI System, read this chapter carefully.

The contents of Chapter 2 are outlined below.

  • System Outline

Explains the outline of the OAI system

  • System Configuration

Explains the configuration of the OAI system

  • Interface with External Computer (General-Purpose Information Processing Equipment)

Explains the conditions for interface with external computer, and use of the related circuit cards

Page 14 of the NEC ND-70895 (E) user manual — 2. System Outline
Pagina 14 · klik om te vergroten
Pagina 14

SYSTEM OUTLINE System Outline

2. System Outline

2.1 OAI (Open Application Interface) System

1. The OAI system is the interface that joins a variety of facilities of the NEAX2400 IMX to the application programs of the external computer (general-purpose information processing equipment) of the user.
2. The NEAX2400 IMX can be controlled by the external computer through the OAI system.
3. The OAI system diversifies the information processing functions of the NEAX2400 IMX, thus offering users’ unique added values.
4. For implementing the OAI system, an Interface Processor (IP) is provided to the NEAX2400 IMX.
5. The IP controls the communication protocol between the NEAX2400 IMX and the UAP (User’s Application Processor of the external computer) in accordance with the basic reference model of the Open Systems Interconnection (OSI) standardized by the ISO ( Note ).

2.2 Software Structure in the OAI System

The software structure in the OAI system is shown in Figure 2-1. So far, the software structure of the NEAX2400 IMX is generally categorized into three major blocks: Input Processing Block, Internal Processing Block, and Output Processing Block. When the Input Processing Block detects a call, the Internal Processing Block analyzes and identifies the call. In accordance with the result of this processing, the Output Processing Block executes required switching operations, controlling of lamps/keys, etc. To meet these processing requirements, a conventional arrangement is made every time a request for the application software arises. The modules of the Input Processing Block and the Output Processing Block are replaced with those corresponding to such a request. However, in the case of the OAI system, each unit function to be made available for the computer in the Input Processing Block and the Output Processing Block is defined as a facility (each slant lined portion in Figure 2-1) in advance, so that each of these facilities may be directly controlled by the external computer through the OAI interface. For example, the key information input by processing of key receiving is not processed within NEAX2400 IMX, but is analyzed by the external computer. As a result of this processing by the external computer, all the related messages are shown on a digital display and a lamp display at corresponding terminals. In other words, the OAI interface has released the function of the conventional internal processing to the external computers.

Page 15 of the NEC ND-70895 (E) user manual — 2. System Outline
Pagina 15 · klik om te vergroten
Pagina 15
NEC ND-70895 (E) — 2. System Outline diagram (page 15)
Afb. 4 · 2. System Outline

Processing by External Computer portion is the unit function (partial) to be released by the OAI system.

Equivalent to the internal processing of the NEAX2400 IMX

Figure 2-1 Software Structure in the OAI System

Page 16 of the NEC ND-70895 (E) user manual — 2.2.1 Facilities
Pagina 16 · klik om te vergroten
Pagina 16

SYSTEM OUTLINE System Outline

2.2.1 Facilities

Each of the unit functions of the NEAX2400 IMX, such as switch control function, terminal control function, etc., that can be controlled by the application of the computer is referred to as “facility”. The facilities can be categorized in two kinds as per the operating pattern; one is “Provider Facility” and the other is “Performer Facility”.

  • Provider Facility A facility of this kind is capable of communicating with one Application Program (AP) on the computer, and executes start-up, etc. of an AP on the computer.
  • Performer Facility A facility of this kind is capable of communicating with plural application programs (AP) on the computer. It is activated from each AP as the common facility and executes required processing in accordance with the control information given from the AP.

Each of the main facilities is outlined in the following.

1. Provider Facilities

(a) Terminal Mode Set Facility (MSF) With a specific key depressed on a terminal, this facility sets terminal mode. When terminal mode is set by this facility, a communication path is set up between the terminal and the AP on the computer. (Figure 2-2)

NEC ND-70895 (E) — 2.2.1 Facilities diagram (page 16)
Afb. 5 · 2.2.1 Facilities

Figure 2-2 Concept of MSF

Page 17 of the NEC ND-70895 (E) user manual — SYSTEM OUTLINE
Pagina 17 · klik om te vergroten
Pagina 17

SYSTEM OUTLINE

(b) Terminal Multiple Information Transfer Facility (TMF) This facility executes batch transfer of dial number information entered from a terminal, card information provided from the card reader, etc. to the AP. (Figure 2-3)

NEC ND-70895 (E) — SYSTEM OUTLINE diagram (page 17)
Afb. 6

Figure 2-3 Concept of TMF

(c) Call Event Transfer Facility (ETF) This facility edits the detailed data (call duration, etc.) pertaining to calls at terminals accommodated in the NEAX2400 IMX, and provides the edited information to the computer. (Figure 2-4)

NEC ND-70895 (E) — SYSTEM OUTLINE diagram (page 17)
Afb. 7

Figure 2-4 Concept of ETF

System Outline

Page 18 of the NEC ND-70895 (E) user manual — 2.2.1 Facilities
Pagina 18 · klik om te vergroten
Pagina 18

SYSTEM OUTLINE System Outline

(d) Authorization Code Facility (ACF) Upon accepting a connection request and/or a service request from a terminal, this facility transfers the ID code of that specific terminal to the AP and also executes either connection processing or connection restricting processing in accordance with the restriction class information returned from the computer. (Figure 2-5)

NEC ND-70895 (E) — 2.2.1 Facilities diagram (page 18)
Afb. 8 · 2.2.1 Facilities

Figure 2-5 Concept of ACF

(e) Free Location Facility (FLF) This facility establishes the correspondence between the extension number allocated to a terminal and the user’s unique ID code in accordance with the number conversion information provided from the AP. (Figure 2-6)

NEC ND-70895 (E) — 2.2.1 Facilities diagram (page 18)
Afb. 9 · 2.2.1 Facilities

Figure 2-6 Concept of FLF

Page 19 of the NEC ND-70895 (E) user manual — SYSTEM OUTLINE
Pagina 19 · klik om te vergroten
Pagina 19

SYSTEM OUTLINE

2. Performer Facilities

(a) Terminal Control Facility (TCF) This facility controls the LCD, LED, etc. on a terminal concerned as per a control order provided by the AP. It also activates the KTF, NTF, and CRF upon receiving a data read request provided from the AP. (Figure 2-7)

NEC ND-70895 (E) — SYSTEM OUTLINE diagram (page 19)
Afb. 10

Figure 2-7 Concept of TCF

(b) Key Code Transfer Facility (KTF) When a terminal concerned is on the terminal mode, this facility transfers the key code information from that specific terminal to the AP. (Figure 2-8)

NEC ND-70895 (E) — SYSTEM OUTLINE diagram (page 19)
Afb. 11

Figure 2-8 Concept of KTF

System Outline

Page 20 of the NEC ND-70895 (E) user manual — 2.2.1 Facilities
Pagina 20 · klik om te vergroten
Pagina 20

SYSTEM OUTLINE System Outline

(c) Dial Number Transfer Facility (NTF) When a terminal concerned is on the terminal mode, this facility transfers the dialed number information from that specific terminal to the AP. (Figure 2-9)

NEC ND-70895 (E) — 2.2.1 Facilities diagram (page 20)
Afb. 12 · 2.2.1 Facilities

Figure 2-9 Concept of NTF

(d) Switch Control Facility (SCF) This facility executes the processing of an outgoing connection or of releasing the connection between a terminal and another in accordance with the connection control information provided from the AP. (Figure 2-10)

NEC ND-70895 (E) — 2.2.1 Facilities diagram (page 20)
Afb. 13 · 2.2.1 Facilities

Figure 2-10 Concept of SCF

Page 21 of the NEC ND-70895 (E) user manual — SYSTEM OUTLINE
Pagina 21 · klik om te vergroten
Pagina 21

SYSTEM OUTLINE

(e) Restriction Control Facility (RCF) This facility changes the restriction class of a terminal concerned in accordance with a directive given by the AP. The restriction class changing can be made on the basis of each terminal, each group, or each system. (Figure 2-11)

NEC ND-70895 (E) — SYSTEM OUTLINE diagram (page 21)
Afb. 14

Figure 2-11 Concept of RCF

(f) Terminal Mode Reset Facility (MRF) With a direction received from the AP or a specific key depressed on a terminal, this facility resets terminal mode. When terminal mode is reset by this facility, the current communication path (terminal mode status) is released. (Figure 2-12)

NEC ND-70895 (E) — SYSTEM OUTLINE diagram (page 21)
Afb. 15

Figure 2-12 Concept of MRF

System Outline

Page 22 of the NEC ND-70895 (E) user manual — 2.2.1 Facilities
Pagina 22 · klik om te vergroten
Pagina 22

SYSTEM OUTLINE System Outline

(g) Application Language Transfer Facility (ATF) With a direction received from the AP or a specific key depressed on a terminal, this facility sends out the APL information input from an OAI terminal to the AP. (Figure 2-13) The system does not care the contents of the APL information at all.

NEC ND-70895 (E) — 2.2.1 Facilities diagram (page 22)
Afb. 16 · 2.2.1 Facilities

Figure 2-13 Concept of ATF

Page 23 of the NEC ND-70895 (E) user manual — SYSTEM OUTLINE
Pagina 23 · klik om te vergroten
Pagina 23

SYSTEM OUTLINE

2.2.2 Join of Facilities and Application

1. When a facility of the NEAX2400 IMX is controlled by the Application Program (AP) on the UAP computer, the AP and that facility must be connected first. The following is the procedure of this connection.

(a) Set-up of Association A communication path is to be opened so that the AP can communicate with the facility.

(b) Opening of Facility The facility that the AP uses is to be declared to the NEAX2400 IMX, and then the AP and the declared facility are joined.

2. Set-up of Association and Opening of Facility Association is set up by activation from the AP first, and then the association is released along with the stop of the AP. Without this association, the AP cannot communicate with the facility and cannot control the facility, either. Then, the facility must be opened so as to allow the AP to communicate with the facility through the communication path opened by setting up of the association. Opening of facility is executed on each facility basis. As a result of the above procedure, the AP becomes able to freely control each of the facilities of the NEAX2400 IMX, and a variety of applications can be programmed on the computer.

2.2.3 Cope of Application in changeover of CPU System

Associations established between NEAX2400 IMX and External computer are released when changeover of CPU system executes. Therefore each application program cap must set up Association again after changeover of CPU system.

System Outline

Page 24 of the NEC ND-70895 (E) user manual — IP
Pagina 24 · klik om te vergroten
Pagina 24

SYSTEM OUTLINE System Configuration

3. System Configuration

The OAI System can be implemented in the Built-in Type configuration, with which the IP is built in the CPU of the NEAX2400 IMX. The configuration of the NEAX2400 IMX OAI System is as follows.

Single CPU configuration (Figure 2-14)

Dual CPU configuration (Figure 2-15)

IP

External Computer Interface Circuit

Provided with External LAN cable connected from the PBX

EtherTCP/IP

OAI System · Built-in CPU

Page 25 of the NEC ND-70895 (E) user manual — 3. System Configuration
Pagina 25 · klik om te vergroten
Pagina 25

SYSTEM OUTLINE System Configuration

1. The configuration of the NEAX2400 IMX OAI System is as follows.
NEC ND-70895 (E) — 3. System Configuration diagram (page 25)
Afb. 17 · 3. System Configuration

CPU Central Processing Unit (NEAX2400 IMX) CPR RAM: Built in Data Memory

Dterm Digital Multifunction Terminal Dterm Series E

ETHER Ethernet Controller PZ-PC19 Ethernet + TCP/IP protocol con- trol

Page 26 of the NEC ND-70895 (E) user manual — 3. System Configuration
Pagina 26 · klik om te vergroten
Pagina 26

SYSTEM OUTLINE System Configuration

NEC ND-70895 (E) — 3. System Configuration diagram (page 26)
Afb. 18 · 3. System Configuration

CPU Central Processing Unit (NEAX2400 IMX) CPR RAM: Built in Data Memory

Dterm Digital Multifunction Terminal Dterm Series E

ETHER Ethernet Controller PZ-PC19 Ethernet + TCP/IP protocol con- trol

Page 27 of the NEC ND-70895 (E) user manual — (PZ-PC19)
Pagina 27 · klik om te vergroten
Pagina 27

SYSTEM OUTLINE Interface with External Computer

4. Interface with External Computer

4.1 Conditions for Interface with External Computer

The circuit card for interface with the external computer (general-purpose information processing equip- ment), and the interface conditions are shown in Table 2-1.

Table 2-1 Interface Conditions of the Circuit Card

CIRCUIT CARD INTERFACE CONDITIONS

ETHER

(Class A, B, C is available Note)

(PZ-PC19)

Data Transfer Speed 10 Mbps

Number of Interface Ports 1 port/card (16 logical channels/port)

Show 6 more labels / short text on this page
Physical Interface 10BASE-T · Communication Protocol TCP/IP · 1 address/system · Internet Address · 1 Port/Internet Address · TCP port
Page 28 of the NEC ND-70895 (E) user manual — 4. Interface with External Computer
Pagina 28 · klik om te vergroten
Pagina 28

This page is for your notes.

Page 29 of the NEC ND-70895 (E) user manual — CHAPTER 3 INSTALLATION PROCEDURE
Pagina 29 · klik om te vergroten
Pagina 29

CHAPTER 3 INSTALLATION PROCEDURE

1. General

This chapter explains the installation procedure for OAI System of NEAX2400 IMX.

  • Cable Connections with External Computer
  • OAI Software Installation
  • Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX
Page 30 of the NEC ND-70895 (E) user manual — 2. Cable Connections with External Computer
Pagina 30 · klik om te vergroten
Pagina 30

INSTALLATION PROCEDURE Cable Connections with External Computer

2. Cable Connections with External Computer

This section explains cable connections between the NEAX2400 IMX OAI System and the external computer.

2.1 Cable Connections between OAI System and External Computer

The cable connections between the OAI system and the external computer are shown in Figure 3-1.

[PZ-PC19 card (LANI) is used]

  • When the OAI system and the external computer are connected using Ethernet + TCP/IP interface
NEC ND-70895 (E) — 2. Cable Connections with External Computer diagram (page 30)
Afb. 19 · 2. Cable Connections with External Computer

00 01 02 03 04 05 06 07 08 09 10 11

12 13 14 15 16 17 18 19 20 21 22 23

00 01 02 03 04 05 06 07 08 09 10 11

Figure 3-1 Cable Connections Between OAI System and External Computer

(a) Connection diagram

Page 31 of the NEC ND-70895 (E) user manual — INSTALLATION PROCEDURE
Pagina 31 · klik om te vergroten
Pagina 31

INSTALLATION PROCEDURE

3. OAI Software Installation

This section explains the installation procedure for adding the OAI software to the PBX in off-line operation. For more detailed information of program install procedure before the OAI application software install, see “Installation Manual”.

1. By using MEM_HDD command, save all data to the both HDDs.
2. Make the Standard Service Software FD link with the OAI Option Service Software FD, and install it into the HDD.

When OAI system is used in the Fusion Network (OAI Terminal Anywhere), link the ACD Option Service Software for “Agent Anywhere” with the above software FD and install it into all the nodes. (valid since the PBX software R8)

3. Initialize the system (perform IPL, DM loading). PROGRAM=“LOAD” SYSTEM DATA=“OVERRIDE/LOAD”
4. Change system data written in DM.

ASYD SYS1 INDEX31 - b0~b3: CM mounting capacity Normally assign “04”. Note 1 Note 2 Note 3 INDEX79 - b6=0 (OAI service is in service) Note 1 INDEX207 - b0 (IP in system0), b1 (IP in system1) Assign “1” to the corresponding bit for the IP accommodation. INDEX241- b2=1 (Call Processing Event Notification) Note 1 INDEX241- b3=1 (Details of SCF Error Notification) Note 1

OAI service) to 04H.

5. Assign the system data written in NDM.

This data below are necessary when OAI system is used through the Fusion Network.

ASYDN SYS1 INDEX514- NDM usage INDEX533- FPC of the node that provides VNDM (Normally, assign the FPC of the node that has the IP)

OAI Software Installation · [Operation Procedure]

Page 32 of the NEC ND-70895 (E) user manual — 3. OAI Software Installation
Pagina 32 · klik om te vergroten
Pagina 32

INSTALLATION PROCEDURE OAI Software Installation

6. Assign the system data written in LDM.

ASYDL SYS1 INDEX512: FPC of the self-node When OAI system is used through the Fusion Network, this data setting is necessary at each node in the network. INDEX513: 01 Hex (LDM usage) INDEX515~518 b0~b7: IP address (Hex) for PBX over external LAN Note 4 INDEX519~522 b0~b7: Subnet Mask (Hex) for PBX over external LAN Note 4 INDEX523~526 b0~b7: Default Gateway Address for External LAN Note 4 (This data is required when the Host is connected via gateway) INDEX864 - b0=1 (Built-in IP is provided) When OAI system is used in the Fusion Network (OAI Terminal Anywhere) [available since the Series 7400 (Release 8) software], assign “1” at the node that has the IP. INDEX864 b1 :Output the system message (4-R) when TCP-IP is normally disconnected. 0/1=Effective/Ineffective

7. Check the station-to-station connection and confirm no fault status occurs or system messages are output (such as cable connection fault, LCD display fault, memory alarm fault, abnormal interrupt etc.).
8. Program the OAI office data. Also, program the Fusion data to make ACD service effective through Fusion network, if necessary.
9. Save the DM into the HDD by using MEM_HDD.
Page 33 of the NEC ND-70895 (E) user manual — 4. Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX
Pagina 33 · klik om te vergroten
Pagina 33

INSTALLATION PROCEDURE Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX

4. Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX

The procedure for upgrading OAI System NEAX2400 ICS to NEAX2400 IMX is shown below.

4.1 Up Grading Procedure

1. Stop the operation of the external computer by the appropriate procedure.
2. Upgrade the PBX hardware following by the Upgrade Manual for the PBX.
3. Upgrade the PBX software to install the software below.
  • Assortment of software for NEAX2400 IMX Note 1
  • OAI Optional software
4. Program the following OAI commands data again.
  • ASYDL Note 2
5. Start Up the external computer Note 3
  • hardware and software of the external computer
6. Perform the installation test.

“Cable Connections with External Computer”. The TCP Port number of the external computer has to be changed to “60030” for NEAX2400 IMX.

Page 34 of the NEC ND-70895 (E) user manual — 4. Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX
Pagina 34 · klik om te vergroten
Pagina 34

This page is for your notes.

Page 35 of the NEC ND-70895 (E) user manual — CHAPTER 4 COMMANDS
Pagina 35 · klik om te vergroten
Pagina 35

CHAPTER 4 COMMANDS

1. General

This chapter explains the commands that are used in the NEAX2400 IMX OAI System. The contents of this Chapter are outlined below.

  • Configuration of Commands for OAI System

This section explains the construction of each command.

  • Commands

This section explains the functions, parameters, and operating procedure of each command.

Page 36 of the NEC ND-70895 (E) user manual — AADT ACNO AMNO AOAC AOKC LADT LCNO
Pagina 36 · klik om te vergroten
Pagina 36

COMMANDS Configuration of Commands for OAI System

2. Configuration of Commands for OAI System

2.1 Configuration of Commands

The configuration of the commands in use in the NEAX2400 IMX OAI System is shown in Figure 4-1.

OAI System Operating Commands

Commands for OAI System

AADT ACNO AMNO AOAC AOKC LADT LCNO

LMNO LOAC LOKC DFLN

ASYDL

ASYD

AKYD ARNP ASPA

ASYDN

Figure 4-1 Configuration of Commands of the NEAX2400 IMX OAI System

Commands for Business · Commands

Page 37 of the NEC ND-70895 (E) user manual — ASYDL
Pagina 37 · klik om te vergroten
Pagina 37

COMMANDS

3. Commands

This section explains the commands in used in the OAI System.

3.1 List of Commands

Table 4-1 shows a list of commands in use in the OAI system. As for any command other than those in the list, refer to the Feature Programming Manual and Office Data Specification of the NEAX2400 IMX.

Table 4-1 OAI System Command Table List

ABBREV. COMMAND COMMAND

AADT Assignment of Announcement/Dictation Trunks

ACNO Assignment of Conversion Number Data

AKYD Assignment of Key Data for Dterm

AMNO Assignment of Monitored Number

AOAC Assignment of OAI Access Code

AOKC Assignment of OAI Key Code

ARNP Note 2 Assignment of Reverse Numbering Plan Data

ASPA Assignment of Specific Attendant Number

ASYD

ASYDN

Assignment of System Data

ASYDL

DFLN Display of Location Free Numbering

LADT Note 1 List Up of Announcement/Dictation Trunks

LCNO Note 1 List Up of Conversion Number Data

LMNO Note 1 List Up of Monitored Number

LOAC Note 1 List Up of OAI Access Code

LOKC Note 1 List Up of OAI Key Code

omitted.

NEAX2400 IMX.

Commands

Page 38 of the NEC ND-70895 (E) user manual — 3.2 Outline of Commands for OAI System
Pagina 38 · klik om te vergroten
Pagina 38

3.2 Outline of Commands for OAI System

The interrelation among the commands to be used in the OAI System is illustrated in Figure 4-2.

NEC ND-70895 (E) — 3.2 Outline of Commands for OAI System diagram (page 38)
Afb. 20 · 3.2 Outline of Commands for OAI System

: Assignment of System Data : Assignment of Reverse Numbering Plan Data : Assignment of Station Data

Figure 4-2 Interrelation among OAI System Commands

AKYD: This command is used to assign the function key codes (For OAI: 34 ~ 47) to the function key

positions of the Dterm.

AOKC : This command is used to assign the meaning of OAI key code assigned by AKYD command.

AOAC : This command is used to assign the access code/operation code for the designated facility.

This command is used only when the Facility Kind (F-KIND) has been set to “3” (Open Appli- cation Interface) by AOKC command.

determined by the application software to be used at each office.

3.3 Items to Be Explained by Each Command

Each command is described by the following items.

Command : The name implies the command and its functions. (1) Functions : This item outlines the command functions. (2) Precaution : This item explains precaution for use of the command. (3) Parameters : This item explains the meaning of the information (parameters) of the data of

the command. (4) Related CommandsThis item specifies other command or commands pertaining to the same data,

assignment/deletion/change/display/list up of the details of that specific data.

COMMANDS Commands

Page 39 of the NEC ND-70895 (E) user manual — COMMANDS
Pagina 39 · klik om te vergroten
Pagina 39

COMMANDS

AADT

AADT: Assignment of Announcement/Dictation Trunks

1. Functions

This command is used to assign/delete Announcement Trunks or Dictation Trunks.

2. Precaution

When changing the LENS of the currently assigned Announcement/Dictation Trunks, delete the assigned data first by this command, and then change the LENS by Assignment of Trunk Data (ATRK) command. It must be remembered that, if the LENS data are deleted first by ATRK command by mistake, the data currently assigned by this AADT command are automatically deleted.

3. Parameters

TYPE : Announcement Trunk (ANT), Dictation Trunk (DCT) NO. : Message Number D : Disconnect Timer (0/1); Valid when TYPE = ANT 0: Impossible (Repeat) 1: Possible (Disconnect by MSGT) MSGT : Message Timer (2 ~ 120 sec., 2-sec. interval when shorter than 30 sec., 8-sec. interval

when longer than 30 sec.) CP : Connection Pattern Note 0: Multiple Connection 1: Single Connection WAIT : Waiting Timer (0~30 sec., 2-sec. interval) Note

CNT : Number of ANT/DCT Trunks assigned or to be assigned (1 ~ 8) RT : Route Number TK : Trunk Number

4. Related Commands
List UpLADT
Page 40 of the NEC ND-70895 (E) user manual — (D) 0/1
Pagina 40 · klik om te vergroten
Pagina 40

COMMANDS AADT

Announcement/Dictation Trunk Data Assignment Table

MESSAGE NO.

ANT/DCT ASSIGNED

DISCON-

CONNEC-

TRUNK

(NO) MESSAGE

WAITING

NECT TIMER

TION PATTERN

ROUTE NUMBER

TRUNK NUMBER

TYPE (TYPE) ANT/DCT

TIMER (MSGT)

TIMER (WAIT)

NO. OF TRUNKS

(TK) ANT 1 ~ 58 DCT 1 ~ 5

(D) 0/1

(CP)

(CNT)

(RT)

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Disconnect Timer 0 = Impossible 1 = Possible

Show 4 more labels / short text on this page
2 ~ 120 · 0 ~ 30 · 0/1 · 1 ~ 8
Page 41 of the NEC ND-70895 (E) user manual — COMMANDS
Pagina 41 · klik om te vergroten
Pagina 41

COMMANDS

ACNO

ACNO: Assignment of Conversion Number Data

5. Functions

This command is used to assign/delete the conversion number required for selecting a route on a each route basis.

6. Precaution

(a) The data should be assigned to ring-down trunks.

(b) As a conversion number, a monitor number assigned by AMNO command should be set.

7. Parameters

RT : External Route Number TN : Tenant Number of Monitored Number MNO : Monitored Number (Max. 5 digits) Note

8. Related Commands

Monitored Number Assignment: AMNO – Parameter RT – Monitored Number Deletion : AMNO Assignment: ARTD List Up : LCNO Display : ARTD List Up : LRTD

Page 42 of the NEC ND-70895 (E) user manual — (RT)
Pagina 42 · klik om te vergroten
Pagina 42

COMMANDS ACNO

Conversion Number Data Assignment Table

TENANT NUMBER OF MONITORED NUMBER

MONITORED NUMBER

EXTERNAL ROUTE NUMBER

(MNO) MAX. 5 DIGITS (Note)

(RT)

(TN)

Page 43 of the NEC ND-70895 (E) user manual — COMMANDS
Pagina 43 · klik om te vergroten
Pagina 43

COMMANDS

AKYD

AKYD: Assignment of Key Data for D term

9. Functions

This command is used to assign/delete/display the function key data, multi-line data or intercom data corresponding to each key on such multi-function telephone terminal as Dterm Series E.

10. Precaution

For the details of Dterm data, refer to the description of AKYD command in the Feature Programming Manual and Office Data Specification for the NEAX2400 IMX. Explanations here will be limited only to the items pertaining to the OAI System.

11. Parameters

FKY: Function Key (valid for KYI=1) 34= OAI Key 1 35= OAI Key 2 36= OAI Key 3 37= OAI Key 4 38= OAI Key 5 39= OAI Key 6 40= OAI Key 7 41= OAI Key 8 42= OAI Key 9 43= OAI Key 10 44= OAI Key 11 45= OAI Key 12 46= OAI Key 13 47= OAI Key 14 52= Speaker 59= Release

Page 44 of the NEC ND-70895 (E) user manual — COMMANDS AMNO
Pagina 44 · klik om te vergroten
Pagina 44

COMMANDS AMNO

AMNO: Assignment of Monitored Number

12. Functions

This command is used to assign/delete Monitored Numbers.

13. Precaution

Monitored Number (MON) is a number of maximum 5 digits consisting of 0 ~ 9, “*” and “#”. Note that, in the case of a hotel system, UCD Pilot Number (STN) is a number of maximum 6 digits, respectively. As NMI value, use a different value for each MON to be assigned.

14. Parameters

TN : Tenant Number MNO : Monitored Number (Max. 5 digits) NMI : Monitored Number Index (1 ~ 4095) UCD : Going by UCD when monitor status is not requested from AP 0: Not going by UCD 1: Going by UCD STN : UCD Pilot Number (Max. 5 digits) Note

[In the case of Hotel System]

A/GDesignation of Administration/Guest Room A: For Administration G: For Guest Room
15. Related Commands
List UpLMNO
Page 45 of the NEC ND-70895 (E) user manual — GOING BY UCD WHEN
Pagina 45 · klik om te vergroten
Pagina 45

COMMANDS

AMNO

Monitored Number Assignment Table

GOING BY UCD WHEN

DESIGNATION OF ADMINISTRATION/

MONITORED

MONITOR STATUS IS NOT REQUESTED FROM

UCD PILOT

MONITORED NUMBER INDEX

TENANT NUMBER

NUMBER

NUMBER

GUEST ROOM (A: FOR ADMINI

(MNO) MAX. 5 DIGITS

(STN) MAX. 5 DIGIT

(NMI) 1 ~ 4095

(TN)

AP (UCD)

G: FOR GUEST

(Note 1)

(Note 1)

ROOM) (Note 2)

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Going by UCD when monitored status is not requested from AP :0/1 = Not Going By UCD/Going By UCD.

0/1

Page 46 of the NEC ND-70895 (E) user manual — COMMANDS AOAC
Pagina 46 · klik om te vergroten
Pagina 46

COMMANDS AOAC

AOAC: Assignment of OAI Access Code

16. Functions

This command is used to assign/delete the Facility Kind and the Operation Code on a basis of each service access code of the OAI System.

17. Precaution

(a) When setting a minus value (less than 0) to the parameter “OP-CODE”, add “-” (minus symbol) ahead to the value. If the set value is a positive value, it is automatically interpreted to be a positive value even if “+” (plus symbol) is not added ahead of the value.

(b) For assigning OAI access codes, it is necessary to assign the necessary number of digits of OAI access codes by AOKC command in advance to assigning the codes.

18. Parameters

OAI-ACC : OAI Access Codes (000 ~ ###) (Max. 3 digits) F-KIND : Facility Kind (1 ~ 15)

1. Terminal Mode Set Facility (MSF) 2: Terminal Multiple Information Transfer Facility (TMF) 3: Not used 15: OP-CODE : Operation Codes (128~ 255)

When F-KIND = 1, 128 ~ 191 When F-KIND = 2, 192 ~ 255

19. Related Command
List UpLOAC
Page 47 of the NEC ND-70895 (E) user manual — OAI ACCESS CODE
Pagina 47 · klik om te vergroten
Pagina 47

COMMANDS

AOAC

OAI Access Code Data Assignment Table

OAI ACCESS CODE

FACILITY KIND

OPERATION CODE

(MAX 3 DIGITS)

(1/2) (F-KIND)

128 ~ 255 (OP-CODE)

(OAI-ACC)

Page 48 of the NEC ND-70895 (E) user manual — 128 (0080)H: MSF
Pagina 48 · klik om te vergroten
Pagina 48

COMMANDS AOKC

AOKC: Assignment of OAI Key Code

20. Functions

This command is used to assign/delete the Facility Kind and the Operation Code on a basis of each function key on the Dterm.

21. Precaution

(a) The OAI code for which F-KIND = 3 (Open Application Interface) can be assigned is only one per system.

(b) When deleting the Open Application Interface (OAI) key code for which F-KIND = 3 is assigned, it is necessary, in advance to the intended deletion, to delete all the OAI access code data assigned by AOAC.

(c) When OAI key data has been assigned/deleted on basis of a function key by this command, operation of the OAI key is ignored only once immediately after that assignment/deletion or immediately after a system initialization.

22. Parameters

KEY-CODE: OAI Key Codes (1 ~ 31) Note 1 F-KIND : Facility Kind (1 ~ 15)

1. Terminal Mode Set Facility (MSF) 2: Terminal Multiple Information Transfer Facility (TMF) 3: Open Application Interface (OAI) 4: Key Code Transfer Facility (KTF) 5. Not used 15: C-TONE : Chime control on normal end of MSF, TMF, and OAI
0. To be controlled 1: Not to be controlled (No Tone) NND : Necessary Number of Digits (1 ~ 3) Note 2 OP-CODE : Operation Codes Note 3 (128 ~ 255) Operation Codes

128 (0080)H: MSF

OAI (Terminal Mode Set Facility) 191 (00BF)H: MSF 192 (00C0)H: TMF

OAI (Terminal Multiple Information Transfer Facility) 255 (00FF)H: TMF

Page 49 of the NEC ND-70895 (E) user manual — PARAMETER KEY CODE AKYD COMMAND PARAMETER FKY
Pagina 49 · klik om te vergroten
Pagina 49

COMMANDS

AOKC

below.

PARAMETER KEY CODE AKYD COMMAND PARAMETER FKY

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ~ 31

34 35 36 37 38 39 40 41 42 43 44 45 46 47 Not used

follows:

F-KIND = 1OP-CODE = 128 ~ 191 F-KIND = 2: OP-CODE = 192 ~ 255
23. Related Commands
List UpLOKC
Page 50 of the NEC ND-70895 (E) user manual — (0/1) (C-TONE)
Pagina 50 · klik om te vergroten
Pagina 50

COMMANDS AOKC

OAI Key Code Data Assignment Table

NECESSARY NUMBER OF DIGITS

OPERATION CODE

CHIME CONTROL ON NOR-

OAI KEY CODE

FACILITY KIND

MAL END OF MSF, TMF

(1 ~ 31) (KEY-CODE)

(1 ~ 15) (F-KIND)

(1 ~ 3) (NND) (Note 1)

(128 ~ 255) (OP-CODE) (Note 2)

(0/1) (C-TONE)

hand by Assignment of OAI Access Code Data (AOAC) command.

Page 51 of the NEC ND-70895 (E) user manual — 192 (00C0): TMF
Pagina 51 · klik om te vergroten
Pagina 51

COMMANDS

AOKC

Table of Operation Codes

OPERATION CODE REMARKS

128 (0080): MSF

OAI

191 (00BF): MSF

(Terminal Mode Set Facility)

192 (00C0): TMF

OAI

255 (00FF): TMF

(Terminal Multiple Information Transfer Facility)

Page 52 of the NEC ND-70895 (E) user manual — TENANT NUMBER
Pagina 52 · klik om te vergroten
Pagina 52

COMMANDS ASPA

ASPA: Assignment of Specific Access Code

24. Functions

This command is used to assign/delete/display each data which respectively determines what kind of service should be executed and/or which route should be used, etc. when a special access code, C.O. line access code or Tie-Line access code has been dialed.

25. Precaution

(a) For the details of special access code data, refer to the description of ASPA command in the Feature Programming Manual and Office Data Specification for the NEAX2400 IMX. Explanations here will be limited only to the items pertaining to the OAI System.

(b) For assigning OAI Dial Number Batch Transfer (SRV = SSCA, SIDA = 69), be sure to set the number of digits (max. 3 digits) of the OAI access code to Necessary Number of Digits (NND).

26. Parameters
SIDAService Feature Index A (69) 69: OAI Dial Number Batch Transfer (TMF)

Specific Access Code Data Assign Table

The Office Data Sheets of this ASPA command are attached only to the pages pertaining to the data to be assigned in the OAI System. Replace these Office Data Sheets with those for ASPA command of the NEAX2400 IMX.

Table 4-2 Supplementary Service Codes

TENANT NUMBER

ACCESS

CONNECTION STATUS INDEX

KIND OF SERVICE

CODE (ACC)

(SRV) SERVICE FEATURE INDEX A

(TN)

(CI)

REMARKS

(SIDA)

1 ~ 31 1 ~ 3 DIGITS N/H/B SSCA

SSCA 69 OAI Dial Number Batch Trans- fer (TMF) H Hooking

N Normal

Page 53 of the NEC ND-70895 (E) user manual — COMMANDS
Pagina 53 · klik om te vergroten
Pagina 53

COMMANDS

ASYD

ASYD: Assignment of System Data

27. Functions

This command is used to assign System Data 1, 2, and 3.

28. Precaution

For the details of the system data, refer to the description of ASYD command in the Office Data Specification for the NEAX2400 IMX.

Page 54 of the NEC ND-70895 (E) user manual — (MTC)
Pagina 54 · klik om te vergroten
Pagina 54

COMMANDS ASYD

System Data Assign Table (1)

The Office Data Sheets of this ASYD command are provided only for the data to be assigned in the OAI System. Use these Office Data Sheets together with those for ASYD command of the NEAX2400 IMX.

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA INDEX (INDEX)

DATA (DATA) 00– FF (Hex)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

Call Event Transfer Facility (ETF) Call Base Table Save and ETF Ser- vice is provided

0/1Unrequired/Required (3 hours)

0 b6 Fixed to 0

0 b7 Not used

b0 Miscellaneous Timer Counter

Message sending Guard Timer for Message Center Interface.

(MTC)

(00 ~ 1F Hex)

Guard Time after sending data to Message Center:

Time Value Setting is (MTC) × 128 msec.

(When this data is 00 Hex, Timer value is 0 msec.)

Be sure to set “1” when using SSFR (FN = 5, SRID = 0)

MCI Message Waiting Lamp Function

0/1Not provided/Provided

0 b6 Not used 0 b7

Show 12 more labels / short text on this page
0 b0 · 0 b1 · 0 b2 · Not used · 0 b3 · 0 b4 · b5 · b1 · b2 · b3 · b4 · b5
Page 55 of the NEC ND-70895 (E) user manual — DATA
Pagina 55 · klik om te vergroten
Pagina 55

COMMANDS

ASYD

System Data Assign Table (1)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

0 b0 Equipped capacity of the Common Memory (CM): 1 ~ 4 Mbyte

Assign “6” Hex. when FLF Fusion service is used. (Available since the PBX software R8)

Not used 0 b5

Traffic Measurement Indication 0/1 = CCS Indication/Erlang Indication

Timer Internal Between Messages (TCFI) Timer

b2 b1 b2 b1 0 0 = 2 seconds 1 1 = Application Dependent 0 1 = 4 seconds (Standard Assignment) 1 0 = 8 seconds

Display for TCFD 0/1 = MSG/Last input 0 = Normal assignment

SCF(FN = 127) Tone Control 0/1 = Invalid/Valid

0 b5 Not used 0 b6

Traffic Measurement for Terminal and Route Traffic (ATRF) 0/1 = Out/In service

Show 12 more labels / short text on this page
0 b1 · 1 b2 · 0 b3 · 0 b4 · 0 b6 · 0 b7 · b0 · b1 · b2 · 0 b3 · 0 b4 · b7
Page 56 of the NEC ND-70895 (E) user manual — TN RT TRK
Pagina 56 · klik om te vergroten
Pagina 56

COMMANDS ASYD

System Data Assign Table (1)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

Called Number Display when forwarding to Attendant Console 0/1 : Out/In service

Flashing display of Line Lockout on Attendant Console BLF 0/1 : In service/Out

Route No. Display on Attendant Console

b3 b2 0 0:

b3 b2 0 1:

TN RT TRK

RT TRK

One digit dialing instead of SHF (DP TEL only) 0/1 : Not required/Required

Priority order for answering via ANSWER key 0 : Priority according to Type of Call 1 : Priority according to the order call termination

Connection of SCF Announcement 1available

Send Warning Tone to interrupted parties when Executive Right of Way service is in operation 0/1 : Required/Not required

Day/Night Mode Change via the ATTCON Handset Jack 0/1: Not required/Required

0 b1 Not used

b2 MW Refresh 0/1 :Not required/Required

b3 Service Module Interface 0/1: Not required/Required

1 b4 Module in which PFT card is mounted PIM (Always assign “11”) 1 b5

0 b6 Not used 0 b7

Show 9 more labels / short text on this page
b0 · b1 · b2 · b3 · 0 b4 · b5 · b6 · b7 · b0
Page 57 of the NEC ND-70895 (E) user manual — DATA
Pagina 57 · klik om te vergroten
Pagina 57

COMMANDS

ASYD

System Data Assign Table (1)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

Calling and Intermediate Station Number indication (Dterm and ATTCON) 0/1: Out/In service (Always assign “1”)

Kind of Service Class indication (Dterm) 0/1: Out/In service (Always assign “1”)

0 b2 Not used

Station Number Display with 8-digit Name Display 0/1: Out/In service

0 b4 Fixed to “0”

Name Display Service 0/1Not to be serviced/To be serviced (FLF: Free Location Facility)

0 b6 Not used 0 b7

Line Preference Service via AKYD 0/1: Out/In service

0 b1 Not used

Split Call Forwarding Service 0/1Out/In service

0 b3 Not used

Zip tone control at the time of SC F:Monitor connection 0/1: Not to be controlled/To be controlled

Name Display Service for Calling Party Only 0/1: Out/In service Note 1

OAI Service 0/1In/Out service Note 2

0 b7 Not used

invalid. Note 2: If, at an office in service with this bit set to “1” (No OAI Service is Provided), the bit value is to be changed

to “0” (OAI Service is Provided).

Show 9 more labels / short text on this page
1 b0 · 1 b1 · b3 · b5 · b0 · b2 · b4 · b5 · b6
Page 58 of the NEC ND-70895 (E) user manual — DATA
Pagina 58 · klik om te vergroten
Pagina 58

COMMANDS ASYD

System Data Assign Table (1)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

0 b0 Not used

Message Reminder Service-Key used for Message Deletion (Dterm) 0/1 = # key/* key

b2 Fixed to “0”

TCF (I) : LCD Display Control 0: Top Line 16-digits display control 1: Second Line 16-digits display control

Not used 0 b5

Show 5 more labels / short text on this page
b1 · b3 · 0 b4 · 0 b6 · 0 b7
Page 59 of the NEC ND-70895 (E) user manual — DATA
Pagina 59 · klik om te vergroten
Pagina 59

COMMANDS

ASYD

System Data Assign Table (1)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

b0 No. 0 CPU Mounted Status of IP00/1:Not mounted/Mounted

b1 No. 1 CPU Mounted Status of IP00/1:Not mounted/Mounted

Show 7 more labels / short text on this page
0 b2 · 0 b3 · 0 b4 · Not used · 0 b5 · 0 b6 · 0 b7
Page 60 of the NEC ND-70895 (E) user manual — 1 ~ F
Pagina 60 · klik om te vergroten
Pagina 60

COMMANDS ASYD

System Data Assign Table (1)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

Data Port Chime Control by SCF 0/1: To be controlled/Not to be controlled

Name Display Service 0/18 digits/16 digits

Call Status Monitor Facility Notification (SMFN) 0/1: Invalid/Valid

SCF Return Error Detail Notification 0/1: Invalid/Valid

Not used 0 b5

b0 Miscellaneous Timer Counter (MTC)

Value for OAI Host Computer Answer Wait Timer (TC) × (MTC) is to be set.

1 ~ F

b4 Timer Class (TC) 0: – 3: 2 sec.6:– 1: 64 msec. 4: 30 sec.7:– 2: – 5: –

When the data is 00 (Hex), the timer value becomes 8 minutes. Note

0 b7 Not used

Show 12 more labels / short text on this page
b0 · b1 · b2 · b3 · 0 b4 · 0 b6 · 0 b7 · b1 · b2 · b3 · b5 · b6
Page 61 of the NEC ND-70895 (E) user manual — DATA
Pagina 61 · klik om te vergroten
Pagina 61

COMMANDS

ASYD

System Data Assign Table (1)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

SCF Call origination from the first party notification 0/1 = Ineffective/Effective

b1 Not used

Access to Announcement trunk is controlled: 0 = by the timer, 1 = by the DAT

Output pattern of INS information by SMFN 0/1: HEX/ASCII

Not used b5

Show 6 more labels / short text on this page
b0 · b2 · b3 · b4 · b6 · b7
Page 62 of the NEC ND-70895 (E) user manual — DATA
Pagina 62 · klik om te vergroten
Pagina 62

COMMANDS ASYD

System Data Assign Table (3)

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00– FF (Hex)

DATA INDEX (INDEX)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

0. 255

DATA

0/1 BIT

b0 Designation of the initial mode of the card reader 000: PB Sender 100 001: LP Command : Not used 010: – 111 011: Data channel

Show 9 more labels / short text on this page
b1 · ~ · b2 · 0 b3 · 0 b4 · 0 b5 · Not used · 0 b6 · 0 b7
Page 63 of the NEC ND-70895 (E) user manual — COMMANDS
Pagina 63 · klik om te vergroten
Pagina 63

COMMANDS

DFLN

DFLN: Display of Location Free Numbering

29. Functions

This command is used to check the assigned data of Location Free Numbering Service. When this command is activated, the assigned data are displayed on a basis of each designated station number.

30. Precaution

The data to be displayed by this command are those assigned from the User Application Processor (UAP) and thus they cannot be assigned by a command.

31. Parameters

[Input Parameters] F : Function Kind (0/1) LSTN : Logical Station Number (ID-No. Max. 5 digits) Note 1 TN : Tenant Number Note 2 PSTN : Physical Station Number (Station Number) Note 2

[Display Parameters] RSCRoute Restriction Class SFC : Service Feature Restriction Class DC : Digit Code
32. Related Commands
Page 64 of the NEC ND-70895 (E) user manual — COMMANDS ASYDN
Pagina 64 · klik om te vergroten
Pagina 64

COMMANDS ASYDN

ASYDN: Assignment of System Data in NDM

33. Function

This command is used to assign system data 1 and 2.

34. Precautions
1. This section only explains about ASYDN command for OAI system. 2. For more details of ASYDN command, see the “Office Data Specification.”
35. Parameters

Refer to the following page.

Page 65 of the NEC ND-70895 (E) user manual — DATA INDEX (INDEX) 0 – 1535
Pagina 65 · klik om te vergroten
Pagina 65

COMMANDS

ASYDN

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA (DATA) 00 – FF (Hex)

DATA INDEX (INDEX) 0 – 1535

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS (MDATA)

DATA

0/1 BIT

b0 Network Data Memory (NDM) usage. Assign data “1 (the memory block is used)” for the corresponding memory block. b1 b2 b3 b4 b5 b6 b7

bit Memory Block b0 Memory Block #0 b1 Memory Block #1 b2 Memory Block #2 b3 Memory Block #3 b4 Memory Block #4

Set up Fusion Point Code (FPC) of Node which basic VNDM is mounted on. (1~253)

864 b3 Multiple IPs 0/1 = Out/In Service Note 1

FLF Fusion Service 0/1 = Invalid/Valid Note 2

ASYDN. Note 2: Available since the Series 7400 (Release 8) software.

Show 17 more labels / short text on this page
b0 · b1 · b2 · b3 · b4 · b5 · b6 · b7 · b0 · b1 · b2 · b3 · b4 · Not used · b5 · b6 · b7
Page 66 of the NEC ND-70895 (E) user manual — COMMANDS ASYDL
Pagina 66 · klik om te vergroten
Pagina 66

COMMANDS ASYDL

ASYDL: Assignment of System Data into Local DM (LDM)

36. Function

This command is used to assign and change system data for OAI activated via FCCS.

37. Precautions

ASYDL command is comprised with System Data-1, INDEX 512-1535. This section only explains about ASYDL command for OAI System.

38. Parameters

Refer to the following pages.

Page 67 of the NEC ND-70895 (E) user manual — DATA INDEX (INDEX) 512-1535
Pagina 67 · klik om te vergroten
Pagina 67

COMMANDS

ASYDL

SYSTEM

BIT CORRESPONDING

SYSTEM

DATA (DATA) 00 – FF (Hex)

DATA INDEX (INDEX) 512-1535

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

DATA

0/1 BIT

b0 Fusion Point Code (FPC) of self node in hexadecimal. FPC 1-253 (01 Hex-FD Hex)

b1 b2 b3 b4 b5 b6 b7

b0 Local Data Memory (LDM) usage. Assign data “1 (the memory block is used)” for the corresponding memory block. b1 b2 b3 b4 b5 b6 b7

bit Memory Block b0 Memory Block #0 b1 Memory Block #1 b2 Memory Block #2

515 IP Address (Hex) for PBX over External LAN Note: This data is valid when the PBX is connected to the external PC LAN. When 172.16.253.0 (default IP address) for the PBX is used, this data setting is not necessary. Example: IP Address : 133.206.8.1

INDEX Set Hex 515 85 516 CE 517 08 518 01

519 Subnet Mask (Hex) for PBX over External LAN Note: This data is valid when the PBX is connected to the external PC LAN. When 172.16.253.0 (default IP address) for the PBX is used, this data setting is not necessary. Example: Subnet Mask : 255.255.0.0

INDEX Set Hex 519 FF 520 FF 521 00 522 00

Page 68 of the NEC ND-70895 (E) user manual — DATA TYPE (SYS)
Pagina 68 · klik om te vergroten
Pagina 68

COMMANDS ASYDL

BIT CORRESPONDING

SYSTEM

SYSTEM

DATA INDEX (INDEX) 512-1535

DATA (DATA) 00 – FF (Hex)

DATA TYPE (SYS)

DATA SYSTEM DATA CONTENTS

DATA

0/1 BIT

Default Gateway Address of External LAN Gateway Address (IP address of Router) of Network connecting PBX. Note: This data is valid when the PBX is connected to the external PC LAN. In the case of no Network Gateway, assignment data is 00 Hex. in Index 523 through 526.

ExampleDefault Gateway Address : 133.206.8.254

INDEX Set Hex 523 85 524 CE 525 08 526 FE

Page 69 of the NEC ND-70895 (E) user manual — CHAPTER 5 OFFICE DATA DESIGN
Pagina 69 · klik om te vergroten
Pagina 69

CHAPTER 5 OFFICE DATA DESIGN

1. General

This chapter explains the procedure for setting the office data required in the NEAX2400 IMX OAI System. As for the office data setting procedure of the NEAX2400 IMX System itself, refer to the System Data Design Manual.

The description of this Chapter consists of the following contents.

  • Procedure for Setting Basic Office Data for OAI System

This section explains the procedure for setting the basic office data of the OAI system.

  • Procedure for Setting Office Data for OAI Services

This section explains the procedure for setting the office data of the main services of the OAI system.

Page 70 of the NEC ND-70895 (E) user manual — 1. ASYD/ASYDL
Pagina 70 · klik om te vergroten
Pagina 70

OFFICE DATA DESIGN Procedure for Setting Basic Office Data for OAI System

2. Procedure for Setting Basic Office Data for OAI System

The procedure for setting the office data for OAI system is explained in the following.

2.1 Data for OAI System

1. ASYD/ASYDL

ASYD-SYS1 INDEX31 - b0 ~ 3 : CM mounting capacity (Normally Assign “04”.) INDEX79 - b6 = 0 (OAI service is in service) INDEX207 - b0 (IP in system 0), b1 (IP in system 1) Assign “1” to the corresponding bit for the IP accommodation. INDEX241 - b2 = 1 (Call Processing Event Notification) INDEX241 - b3 = 1 (Details of SCF Error Notification) ASYDL-SYS1 INDEX513 : 01 Hex (LDM usage) INDEX515~518 : IP address (Hex) for PBX over External LAN INDEX519~522 : Subnet Mask (Hex) for PBX over External LAN INDEX523~526 : Default Gateway Address for External LAN (This data is required when the Host is connected via gateway) INDEX864 - b0 = 1 (Built-in IP is provided) INDEX864 b1 : Output the system message (4-R) when TCP-IP is normally

disconnected. 0/1 = Effective/Ineffective

2. ARNP (Reverse Numbering Plan Data) If necessary, assign the self office code when assigning office information within a message of the facility
Page 71 of the NEC ND-70895 (E) user manual — 2.2 Data for OAI Terminal
Pagina 71 · klik om te vergroten
Pagina 71

OFFICE DATA DESIGN Procedure for Setting Basic Office Data for OAI System

2.2 Data for OAI Terminal

In the case of Dterm

1. ASDT (In the case of Business; Station Data), AASP (In the case of Hotel system; Station Data) Note 1 Assign station data
Voice PortTEC12 Data Port: TEC13 (Normal setting for others)
2. AKYD (D term Key Data) Assign the function key data of D term

Assign FKY34–47 to any positions of FKY 1–16. (Normal setting for others)

3. AOKC (OAI Key Code Data) Assign the OAI key code data

OAI key code 1 ~ 14 respectively corresponds to FKY34 ~ 47 of AKYD

4. AOAC (OAI Access Code Data) If necessary, assign OAI access code data when using “OAI key + Access code” system to activate the application by MSF/TMF

In the case of Single-Line Telephone

1. ASYD (System Data) Assign OAI Host Computer Respond Wait Timer
2. ANPD (Numbering Plan Data) Assign the minimum necessary number of digits for OAI Dial Number Continuous Transfer Code Note 2
3. ASPA (Special Access Code Data) Assign the OAI Dial Number Continuous Transfer Access Code

SSCA: 69 (OAI Dial Number Continuous Transfer) NND : Necessary Number of Digits of OAI access code (Max. 3 digits)

4. AOAC (OAI Access Code Data) Assign OAI access code data
Page 72 of the NEC ND-70895 (E) user manual — 3. Procedure for Setting Office Data for OAI Services
Pagina 72 · klik om te vergroten
Pagina 72

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3. Procedure for Setting Office Data for OAI Services

This section explains the outline, using conditions, and office data setting procedure of the main OAI service functions.

3.1 Switch Control Facility (SCF)

3.1.1 Functional Outline

The SCF is the facility that executes, from the Application Program (AP), such control operations as connections/disconnections between NEAX2400 IMX-accommodate terminal (Dterm) and another, between a Dterm and a C.O. Line Outgoing/Incoming Trunk, etc. The SCF has several functions (FN), and explanations will be given in the following about “Basic Connecting Function (FN = 1) – Make Call (Automatic Answer)” which is one of the several functions.

NEC ND-70895 (E) — 3. Procedure for Setting Office Data for OAI Services diagram (page 72)
Afb. 21 · 3. Procedure for Setting Office Data for OAI Service…
Page 73 of the NEC ND-70895 (E) user manual — 3.1.2 Using Conditions
Pagina 73 · klik om te vergroten
Pagina 73

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.1.2 Using Conditions

1. Normal and abnormal operating sequences pertaining to the basic connection of the SCF are as described below.

Destination Terminal Calling Terminal NEAX2400 Computer (AP)

(a) Upon receiving SCF start request from the AP, the NEAX2400 IMX judges the status (idle, busy, makebusy, etc.) of the designated calling terminal and destination terminal.

(b) If the calling terminal and the destination terminal are idle, the NEAX2400 IMX sends out Return Result to the AP, and places the calling terminal into an outgoing connection status and the destination terminal into ringing status. These are the basic functions.

(c) When the destination terminal designated from the AP is a terminal in the NEAX2400 IMX and automatic answer is designated as the answer type, both the calling and destination terminals can be placed into speech status immediately from the status cited in (b) (After zip tone has been sent to both terminals, the terminals are placed into speech status.). Note that this service function is valid only when the destination terminal is in line selection wait status and also automatic answer is designated as the answer type. In other words, if the destination terminal is in a status other than line selection wait status, the call is to be answered manually. Further, this service function is valid only when the destination terminal is a station (Dterm: Voice) among the SCF Make Call designations. In other words, if the call destination is a trunk, this service function does not work.

Show 5 more labels / short text on this page
[Normal Sequence] · SCF Activated · Terminal Check · Return Result · Connection
Page 74 of the NEC ND-70895 (E) user manual — 3.1.2 Using Conditions
Pagina 74 · klik om te vergroten
Pagina 74

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

Destination Terminal Calling Terminal NEAX2400 Computer (AP)

(a) Upon receiving SCF start request from the AP, the NEAX2400 IMX judges the status (idle, busy, makebusy, etc.) of the designated calling terminal and destination terminal.

(b) If the calling terminal and the destination terminal are in a status other than idle, the NEAX2400 IMX sends out Return Error to the AP.

2. Only digital multifunction telephone (D term Series E) can be designated as a calling terminal.
Show 5 more labels / short text on this page
[Abnormal Sequence] · SCF Activated · Terminal Check · Return Error · <Busy> <Idle>
Page 75 of the NEC ND-70895 (E) user manual — SYS1
Pagina 75 · klik om te vergroten
Pagina 75

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.1.3 Data Programming

1. ASYD (System Data)

SYS1

INDEX 79

b60 (OAI service is available)
2. AKYD (D term Key Data)

Restrict a call origination from the prime line of the terminal of which answer type is designated as automatic answer

S: Outgoing call from a prime line (0/1)

0/1Allowed/Restricted
1. AKYD (D term Key Data)

Cancel restriction on a call origination from the prime line of the terminal of which answer type is designated as automatic answer

S: Outgoing call from a prime line (0/1)

0/1Allowed/Restricted
2. ASYD (System Data)

SYS1

INDEX 79

b61 (OAI service is not available)

Assignment · Deletion

Page 76 of the NEC ND-70895 (E) user manual — 3.2 Call ID Notification (SMFN for ISDN)
Pagina 76 · klik om te vergroten
Pagina 76

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.2 Call ID Notification (SMFN for ISDN)

3.2.1 Functional Outline

This Call ID Notification function is an enhancement of both the Call Termination Notification and the Answer Notification among Call Status Monitor Facility Notification functions of the OAI system, and provides the User’s Application Processor for External Computer (UAP) with the caller’s information when call termination is to be notified about an incoming call from the Integrated Services Digital Network (ISDN) concerned. Likewise, when the called terminal has answered an incoming call, this function also provides the UAP with the ISDN caller’s information.

NEC ND-70895 (E) — 3.2 Call ID Notification (SMFN for ISDN) diagram (page 76)
Afb. 22 · 3.2 Call ID Notification (SMFN for ISDN)

3.2.2 Using Conditions

1. Only when a call has terminated from the ISDN and when the call has been answered, SMFN message is sent out with the caller’s information added. Note, however, that caller’s information may not be added to the message depending on the restrictive conditions pertaining to the caller notification of the ISDN.
2. The number of digits for ISDN caller’s information is maximum 33 for the caller’s number and maximum 20 for call sub-address.
3. The SMFR cannot monitor ISDN terminal, and thus when a call has terminated to an ISDN terminal and the call has been answered, SMFN message is not sent out.
Page 77 of the NEC ND-70895 (E) user manual — SYS1
Pagina 77 · klik om te vergroten
Pagina 77

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

4. When an incoming call terminates from ISDN network, ISDN caller’s number information (subscriber’s number and sub-address) is provided from the central office in the following format.

1≤n ≤54 D C

D C

D C n –1

D C

ISDN Caller’s Number Information

Subscriber number is maximum 33 digits, and the sub-address is maximum 20 digits, and they are separated by the separator “*” (OBH).

3.2.3 Data Programming

1. Assignment

SYS1

INDEX 79

b60 (OAI service is not available) INDEX 241
b21 (OAI Call Status Monitor Facility Notification is not in service)
2. Deletion

SYS1

INDEX 79

b61 (OAI service is not available) INDEX 241
b20 (OAI Call Status Monitor Facility Notification is not in service)

n · ASYD (System Data) · ASYD (System Data)

Page 78 of the NEC ND-70895 (E) user manual — 3.3 MWL Control (SSF) STEP-1
Pagina 78 · klik om te vergroten
Pagina 78

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.3 MWL Control (SSF) STEP-1

3.3.1 Functional Outline

This function allows the Application Program (AP) to provide a single-line telephone equipped with Message Waiting Lamp (MWL) or a Dterm with the following Message Waiting (MW) services by the OAI Service Set Facility (SSF).

1. MW Setting (Turning MW Lamp On)
2. MW Resetting (Flashing MW Lamp)
3. MW CANCEL (Turning MW Lamp Off)
4. LCD Display on each MW type Display contents: Message Waiting (MW) Voice Mail Module (VMM) Text Mail Module (TMM) Facsimile Mail Module (FMM)
NEC ND-70895 (E) — 3.3 MWL Control (SSF) STEP-1 diagram (page 78)
Afb. 23 · 3.3 MWL Control (SSF) STEP-1
Page 79 of the NEC ND-70895 (E) user manual — 3.3.2 Using Conditions
Pagina 79 · klik om te vergroten
Pagina 79

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.3.2 Using Conditions

1. Normal and abnormal operating sequences pertaining to the basic connection of the SSFR are as described below.

Terminal (Dterm) NEAX2400 IMX Computer (AP)

Terminal (Dterm) NEAX2400 IMX Computer (AP)

Show 9 more labels / short text on this page
[Normal Sequence] · SSFR Activated · Received Information Analysis · Service Set/Cancel · Return Result · [Abnormal Sequence] · SSFR Activated · Received Information Analysis · Return Result
Page 80 of the NEC ND-70895 (E) user manual — 3.3.2 Using Conditions
Pagina 80 · klik om te vergroten
Pagina 80

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

2. This service cannot be used simultaneously with other MW control services (VMM/MCI: Message Center Interface/Message Waiting from Station, ATTCON and MAT).
3. The conditions for the telephone that controls MW are as follows.
  • MW can be serviced only on a telephone equipped with MW lamp function.
  • On a single-line telephone and/or D term , MW lamp display position is fixed.
  • On a single-line telephone, MW lamp flashing cannot be controlled (ON/OFF only).
  • MW lamp on/off/flashing, and LCD display can be controlled on a D term . (MW indication is available only on a D term equipped with the indicator.)
  • D term can control only lamp flashing (LCD display cannot be controlled).
4. In the case of MW service by SSFR (Confirm-type Performer facility), the same kinds of display (MW, VMS) as those of MCI (Message Center Interface) are possible.
5. In the case of deletion of all the station data and all the type data, only the same data as those of MCI are deleted. MW service information for stations from the OAI Terminal Control Facility (TCF) are not deleted.
6. In the case of MW service by SSFR, lamp on/flashing/off is immediately indicated at the time of one station control. In the case of deletion of all the station data and all the type data, a delay time of maximum 196 seconds generates until the status of the terminal changes actually.
7. The system configuration for implementing this service is as illustrated below.
NEC ND-70895 (E) — 3.3.2 Using Conditions diagram (page 80)
Afb. 24 · 3.3.2 Using Conditions
Page 81 of the NEC ND-70895 (E) user manual — SYS1
Pagina 81 · klik om te vergroten
Pagina 81

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.3.3 Data Programming

1. ASYD (System Data)

SYS1

INDEX 77

b20 (MW Lamp Refresh Control is in service) INDEX 179
b60 (OAI services are provided)
2. ARPC (Remote Point Code for Centralized Service)

For providing centralized services at the Message Center within a No. 7 CCIS Network, assign the point codes for the remote offices belonging to the main office

CSN: Centralized Service Item No. (1 ~ 7) 1: Message Center CNT: Number of Remote Office Point Codes (1 ~ 32) RPC: Remote Office Point Code (1 ~ 16367)

1. ARPC (Remote Point Code for Centralized Service)

Delete the point codes of the remote offices belonging to the main office

2. ASYD (System Data)

SYS1

INDEX 77

b21 (MW Lamp Refresh Control is not in service) INDEX 179
b61 (OAI services are not provided)

Assignment · Deletion

Page 82 of the NEC ND-70895 (E) user manual — 3.4 TCP/IP Address (Assignment from MAT)
Pagina 82 · klik om te vergroten
Pagina 82

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.4 TCP/IP Address (Assignment from MAT)

3.4.1 Functional Outline

In an OAI system to be connected with the host computer via the Ethernet, this function allows use of TCP/IP port with the self internet address (TCP/IP address) of the NEAX2400 IMX assigned from the MAT.

Also, whether system message “4-R” (IOC card for the host computer is faulty) is to be output or not when the connection with the host computer has been normally disconnected can be selected by switch setting on the Interface Processor (IP).

3.4.2 Using Conditions

1. Due to the hardware limitation, only one physical TCP/IP port can be accommodated per system.
2. Basic Value of TCP/IP Address is “172.16.253.0”.

3. The TCP/IP addresses (A, B, C, D) that cannot be used by this function are as follows. Classes A, B, and C can be used. Note that Host Number = 0 cannot be used. (Conditions [1] ~[3]. Classes D and E cannot be used. (Condition [4]) Class A: [1] 0 A 127 → A, 0, 0, 0 Class B: [2] 128 A 191 → A, B, 0, 0 (0 B 255) Class C: [3] 192 A 223 → A, B, C, 0 (0 B 255, 0 C 255) Class D, E: [4] 244 A → A, B, C, D (0 B 255, 0 C 255, 0 D 255)

4. System message “4-R” output can be stopped by switch setting on the System Data only when TCP connection has been disconnected (Normal) (ERRK=01).
Page 83 of the NEC ND-70895 (E) user manual — SYS1
Pagina 83 · klik om te vergroten
Pagina 83

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.4.3 Data Programming

1. Assignment ASYDL (System Data (LDM)) Assign TCP/IP address

SYS1

INDEX 515 ~ 518

2. Deletion ASYDL (System Data (LDM)) Delete TCP/IP address

SYS1

INDEX 515 ~ 518

Stopping the system message of “4-R”

1. Assignment ASYDL (System Data (LDM))

SYS1

INDEX 864

b1 = 1 (The system message (4-R) is not output when TCP/IP connection is normally

disconnected.)

2. Deletion ASYDL (System Data (LDM))

SYS1

INDEX 864

TCP/IP Address Assignment · b1 = 0

Page 84 of the NEC ND-70895 (E) user manual — 3.5 Name Display
Pagina 84 · klik om te vergroten
Pagina 84

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.5 Name Display

3.5.1 Functional Outline

This service is for displaying information (user’s name, station number, etc.) on the LCD of Dterm.

1. Catch internal call
2. Catch Forwarding Call from Call Forwarding Busy Line, Call Forwarding Absent, Call Forwarding Don’t Answer, Station Hunting, or etc..

3.5.2 Using Conditions

1. Maximum 16 digits of user’s information can be displayed on LCD according to internal numbers.
2. What is available for this service to display, is alphabet, digit, sign or etc..
3. For administrating user’s information clearly, it is not available to use both “Name Display Service” which is assigned by ANDD command and “OAI Service” at same time.
4. It is not available to use both 8-digit Display Service and 16-digit Display Service at same time. For changing from 8-digit Display Service to 16-digit Display Service, can be changed by using “System Data”.
5. There are limitations below for 16-digit Display Service.
  • User’s information can not be displayed on the top line of LCD.
  • User’s information is displayed from the left side of bottom line and if the information is less than 16-digit, the rest of frames will be blank.
  • It is not able to set multi-line on this D term .
6. There is a limitation below for 8-digit Display Service.
  • User’s information is displayed from the middle of top line and if the information is less than 8 digits, the rest of frames will be blank. And the bottom line will display the clock.
7. If the user’s information is not assigned, normally station number will be displayed.
8. There is no guarantee for the user’s information since you change from 16-digit Display Service to 8-digit Display Service.
9. The service will be effective, if either of calling party or called party has D term which has the LCD.
Page 85 of the NEC ND-70895 (E) user manual — INDEX241
Pagina 85 · klik om te vergroten
Pagina 85

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.5.3 Data Programming (Set up from User’s Application)

1. Assignment ASYD SYS1
INDEX3104: mount capacity of Common Memory (CM) 4Mbyte

INDEX78

b0 = 1 (Intermediate Station Number Display is in service) b1 = 1 (Service Assortment Display is in service) b3: Dial Number Display 0/1: Out/In service b5 = 1 (Name Display Service is in service)

INDEX79

b5: Expanded Name Display (displaying 16-digit) 0/1: Out/In service b6 = 0 (OAI Service is in service)

INDEX241

b1Name Display 0/1: 8-digit/16-digit
2. Deletion ASYD SYS1

INDEX78

b0: Intermediate Station Number Display 0/1: Out/In service b1: Service Assortment Display 0/1: Out/In service b3: Dial Number Display 0/1: Out/In service b5 = 0 (Name Display service is Out)

INDEX79

b5: Expanded Name Display (displaying 16-digit) 0/1: Out/In service b6 = 1 (OAI Service is Out)

INDEX241

b1 = 0 (Name Display is displaying 8-digit)

Page 86 of the NEC ND-70895 (E) user manual — 3.6 Inter Node Name Display
Pagina 86 · klik om te vergroten
Pagina 86

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.6 Inter Node Name Display

3.6.1 Functional Outline

Name Display Service is available between the network. Name Display Service means for the facility of displaying letters (alphabet and etc.) on LCD of the Dterm. Catching call from other internal line

3.6.2 Using Conditions

1. When Calling party is calling Called party, the LCD of Calling party will display Called party’s name information by the internal number.
2. If there is no information of Calling party or Called party, only the number of Calling party or Called party’s will be displayed.
3. When there are both 8-digit and 16-digit of Inter Node Name Display Service in same Node, Calling party/Called party’s name will be shown as below.

Inter Node Name Display

Service Calling Party → Called party

Display of Calling party’s name Display of Called party’s name

16-digit → 8-digit 16-digit on Center Line (right side of 8-digit will be blank)

8-digit on Top Line (First 8-digit will be displayed)

8-digit → 16-digit 8-digit on Top Line (First 8-digit will be displayed)

16-digit on Center Line (right side of 8-digit will be blank)

8-digit → 16-digit → 8-digit 8-digit on Top Line 8-digit on Top Line

16-digit → 8-digit → 16-digit 16-digit on Center Line 8-digit on Center Line

4. When Name Display Service is set up for 16-digit, it will be unable to set up multi-line at the D term .
5. When Calling party reaches CCIS call to Called party by using D term Sub-Line, the display of Called party will display the Sub-Line name of Calling party. (Only for 8-digit)
6. The Name Display of Called party indicates prime line only for Both of 8-digit and 16-digit.
7. What is available to display for this service, are alphabet, figure, sign and etc
8. Assign the Name Information Data, based on each D term LEN, by using the Free Location Facility available on the user’s application.
9. The route which is set up Inter Node Display Service and the route which is not set up Inter Node Display Service should be separated from each other.
10. Even Dial Number Display Service is activate, the dial number won’t be displayed between the Inter Node.
Page 87 of the NEC ND-70895 (E) user manual — CCIS
Pagina 87 · klik om te vergroten
Pagina 87

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

11. The objected terminal of Name Display Service is only D term which has LCD.
12. “Office Code” + “Station Number” is normally displayed. However, when use of a logical number is specified, only the logical number without an office code is displayed. (ONE CCIS network is assigned only one logical number.)
13. When a call has been transferred by “Call Forwarding All Outside Line Call” or “Call ForwardingBusy Outside Line Call”, the LCD of Calling Party’s D term will display “Name Information” of Called party, instead of dialed number.
14. When you call to a party by the way of a party which doesn’t have Inter Node Name Display Service in CCIS network, or the other Node of CCIS network, the Name Display Service will not serve.

CCIS

CCIS

CCIS

B Office C Office

D Office (Name Display - System - CCIS is not serviced)

CCIS

CCIS

In the case of (1): Name Display is serviced. In the case of (2): Name Display is not serviced. In the case of (3): Name Display is not serviced.

15. This service can not be used in conjunction with ISDN Information Transfer-CCIS Service.
16. Those below are the Inter Node Services which are able to serve Inter Node Name Display.
  • Voice Call
  • Inter Node Call Forwarding All Call
  • Inter Node Call Forwarding Busy Line
  • Inter Node Call Forwarding No Answer
  • Inter Node Camp On (Only for calling)
  • Message Reminder (Only for outgoing)
17. Those below are the Self Node Services including CCIS Trunk which are able serve Inter Node Name Display.
  • Call Pick Up
  • Ringing for Call Hold
  • Answering for call park
  • Call waiting
  • Catching call from UCD Queuing
18. For the terminal which is able to serve Inter Node Display Service, please see the Item of Name Display Service.
Show 4 more labels / short text on this page
A Office · (1) · (2) · E Office
Page 88 of the NEC ND-70895 (E) user manual — INDEX 241
Pagina 88 · klik om te vergroten
Pagina 88

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.6.3 Data Programming (Set up from User’s Application)

Those below are explanation of the Assignment according to Name Information which is set up from User’s Application.

1. ASYD

SYS1

INDEX 78

b5 = 1 (Name Display Service is in service) b3: Dial Number Display 0/1: Out/In service

INDEX 79

b6 = 0 (OAI Service is in service)

INDEX 241

b1Name Display 0/1: 8-digit/16-digit displaying
2. Route Class Data (ARTD) Change the Route Class Data of CCIS Trunk Busy Line Service (BT): 1 (Active) Number Display Designation (DPLY): 1(Called Party Number Display) ISDN Output Information (CI): 0 (Existing) Inter Node Display Service (IND): 1 (In service)
1. Route Class Data (ARTD) Delete the Route Class Data of CCIS Trunk Busy Line Service (BT): 0/1 (Out/In Service) Number Display Designation (DPLY): 0/1(-/Called Party Number Display) ISDN Output Information (CI): 0 ~ 15 Inter Node Display Service (IND): 0 (Out)

2. ASYD

SYS1

INDEX 78

b5Name Display Service 0/1: Out/In service b3: Dial Number Display 0/1: Out/In service

INDEX 79

b6 = 1 (OAI Service is not in service)

INDEX 241

b1 = 0 (Name Display 8-digit)

Assignment · Deletion

Page 89 of the NEC ND-70895 (E) user manual — 3.7 OAI Fusion
Pagina 89 · klik om te vergroten
Pagina 89

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.7 OAI Fusion

Main advantages of OAI Fusion fall down into the following. OAI Fusion systems can be divided into the following two types:

  • OAI Terminal Anywhere
  • Multiple IPs

3.7.1 OAI Terminal Anywhere

3.7.1.1 Functional Outline

In this configuration (OAI Terminal Anywhere), the OAI terminal can be installed in any Fusion node whether the node has the IP or not (those OAI terminals in multiple nodes are controlled by one IP). In other words, the facilities in multiple nodes (any Fusion node whether the node has the IP or not) are controlled by one IP. (“Facility” which can be used through the Fusion Network varies in “the OAI application”.)

NEC ND-70895 (E) — 3.7 OAI Fusion diagram (page 89)
Afb. 25 · 3.7 OAI Fusion

3.7.1.2 Using Conditions

(a) The Node that accommodates the IP is one node only in a Fusion network.

(b) Telephone Number (max. 5 digits) is used for the station number type to activated OAI system through Fusion network.

(c) Logical Route is used for the route type to activate OAI system through Fusion network.

Page 90 of the NEC ND-70895 (E) user manual — ASYDL/ASYDN
Pagina 90 · klik om te vergroten
Pagina 90

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

(d) The node that accommodates the IP must be initialized when all the other nodes are in on-line mode.

(e) The User’s Application (UAP) must be booted up after the confirmation of the establishment of the Fusion link.

(f) When you add a node/nodes to the network, you have to initialize the node that accommodates the IP.

3.7.1.3 Data Programming

1. Assignment of System Data

(Data for OAI Fusion)

ASYDL/ASYDN

  • The data below must be set to all nodes in the network

(a) ASYDL-SYS1 INDEX512 b0~7: Assign the self-Fusion Point Code (self-FPC) at each node.

(1~253) INDEX865 b0~7: FPC of the node providing IP Note: Assign 0 for the node that providing IP in the self-node only.

(b) ASYDN-SYS1INDEX514NDM usage INDEX533 : FPC number of the node that has the standard VNDM
2. Data programming procedures other than STEP 1 are the same as that of the non-Fusion system. Therefore, only notification or condition of the data programming is shown below in this section.

(a) ASYD/ASYDL • The data below are set to the node that accommodates IP ASYD - SYS1, INDEX207, b0:1=IP0 is used SYS1, INDEX207, b1:0/1=IP1 is not used/used ASYDL - SYS1, INDEX864, b0:1=Built-in IP is used

  • The others are set to all nodes in the Fusion network.
  • (b) Following are the notification Fusion data programming with commands below. For the following commands, assign data by the corresponding commands written in NDM.
  • AMNON (AMNON is used in place of AMNO)
  • ACNON (ACNON is used in place of ACNO)
  • AADTN (AADTN is used in place of AADT)

(c) The AKYD, AOKC command data are set to all nodes in Fusion network to be provided OAI system. (For these commands, assign data by the corresponding commands written in DM)

(1-253)

Page 91 of the NEC ND-70895 (E) user manual — 3.7.2 Multiple IPs
Pagina 91 · klik om te vergroten
Pagina 91

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.7.2 Multiple IPs

3.7.2.1 Functional Outline

In this configuration (Multiple IPs), IP can be accommodated to multiple nodes in a Fusion Network. Since Series 7400 (Release 8) software, establishing the CCIS line is not necessary to use OAI system through the network. (“Facility” which can be used through the Fusion Network varies in “the OAI application”.)

NEC ND-70895 (E) — 3.7.2 Multiple IPs diagram (page 91)
Afb. 26 · 3.7.2 Multiple IPs

This feature is available with Series 7400 (Release 8) software.

3.7.2.2 Using Conditions

(a) Telephone Number (max. 5 digits) is used for the station number type to activated OAI system through Fusion network.

(b) Logical Route is used for the route type to activate OAI system through Fusion network.

(c) Only one IP to be used for “OAI Terminal Anywhere” can be contained in a Fusion Network (Multiple IPs).

(d) IP can be accommodated to multiple nodes in a Fusion Network. However, maximum number of Status Monitoring Requests to a terminal is decided by the system data (max. 8 ports available including UAP). Note that the normal operation is not guaranteed if Status Monitoring is requested to a terminal from more than the number of ports.

Page 92 of the NEC ND-70895 (E) user manual — 3.7.2 Multiple IPs
Pagina 92 · klik om te vergroten
Pagina 92

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

(e) OAI terminals to be controlled from different IPs can not be accommodated in a node.

NEC ND-70895 (E) — 3.7.2 Multiple IPs diagram (page 92)
Afb. 27 · 3.7.2 Multiple IPs

(f) When the IMG-U system is included in a Fusion Network (Multiple IPs), take the following conditions into consideration when programming data.

NEC ND-70895 (E) — 3.7.2 Multiple IPs diagram (page 92)
Afb. 28 · 3.7.2 Multiple IPs

(a) IMG-U system where the OAI terminals are accommodated in multiple Local Nodes. In the IMG-U system, data programming for “OAI terminal Anywhere” must be programmed at the node that has IP (“IP1” in the figure below). In the network, another IP can not be used for “OAI terminal Anywhere” any more.

3.7.2.3 Data Programming

[Notice for Data Programming]

This section shows data programming divided into the types of OAI system (Figure 5-1).

NEC ND-70895 (E) — 3.7.2 Multiple IPs diagram (page 92)
Afb. 29 · 3.7.2 Multiple IPs

The following are the network configuration of OAI system in a Fusion Network.

LEGEND Type IPBX1 - Non - OAI system
Type IIPBX2 - OAI Stand-alone system (OAI system provides OAI function in the self-node only)

Type III : OAI Terminal Anywhere PBX3 - System providing the OAI terminals (Non-IP Node) PBX4 - System providing the OAI terminals (IP-Node)

Figure 5-1 Network Configuration of OAI systems

Page 93 of the NEC ND-70895 (E) user manual — I II III
Pagina 93 · klik om te vergroten
Pagina 93

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

1. The following are the quick reference table of optional software and system data programming for each OAI system configuration. (See Figure 5-1 “Network Configuration of OAI systems” for network configuration of OAI systems.)

Table 5-1 OAI Software and System Data

Type and Node OAI

I II III

PBX1 PBX2 PBX3 PBX4 OAI Software

1 OAI Option Service software (basic) [Series 7400 (Release 8)] 2 ACD Option Service Software for “Agent Anywhere” System Data

3 CM Usage Note 1 (ASYD:SYS1, INDEX31, b0~b3) 0 4 4 4

4 OAI in service/out of service (ASYD:SYS1, INDEX79, b6) 1 0 0 0

5 No.0 CPU Mounted Status of IP00/1: Not mounted/Mounted (ASYD:SYS1, INDEX207, b0) 0 1 0 1

6 No.1 CPU Mounted Status of IP00/1: Not mounted/Mounted (ASYD:SYS1, INDEX207, b1) 0 Note 2 0 Note 2

7 OAI Call Processing Event Notification (ASYD:SYS1, INDEX241, b2) 0 1 1 1

8 SCF Return Error Detail Notification (ASYD:SYS1, INDEX241, b3) 0 1 1 1

9 Built-in IP:Not used/Used (ASYDL:SYS1, INDEX864, b0) 0 1 0 1

10 OAI Terminal Anywhere:Out of service/In service Note 3 (ASYDL:SYS1, INDEX864, b2) 0 0 1 1

11 MULTIPLE IPs:Out of service/In service Note 4 (ASYDL:SYS1, INDEX864, b3) 0 0 1 1

12 FPC Number of the node providing IP (ASYDL:SYS1, INDEX865) 0 0 Note 5 Note 5

13 Number of ports for SMFN (terminal) (ASYDL:SYS1, INDEX864, b4~5) 0 Note 6 Note 6 Note 6

14 FPC Number of Center Node providing VNDM (ASYDN:SYS1, INDEX533) Note 7 Note 7 Note 7 Note 7

: The software is installed to be linked with the standard service software using MSVIP command. Note 1: When CM is used for another function, this setting may be changed.

(Ex. Assign “6” Hex. when FLF Fusion service is used.) Note 2: When the CPU in system 1 is used, assign “1”. Note 3: Assign “1” at the all nodes using “OAI Terminal Anywhere” in the Fusion network that “MULTIPLE IPs” is provided. Note 4: When the all fusion nodes in the network are used for “MULTIPLE IPs”, this data may be assigned using ASYDN. Note 5: This data is required for UAP connection. Note 6: (This data is not necessary for the example above.) Assign this data so that the proper number of ports can be used when

more than three ports of Status Monitoring for terminal (SMFN). The identical data should be assigned at all nodes.

ASYDL SYS1 INDEX864 b4~5:

b5 b4 0 0 =2 ports 0 1 =8 ports Note 7: When the node using “OAI Terminal Anywhere” is included in the Fusion network that “Multiple IPs” is provided, assign

the FPC no. of IP node using “OAI Terminal Anywhere”.

Page 94 of the NEC ND-70895 (E) user manual — I II III
Pagina 94 · klik om te vergroten
Pagina 94

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

2. Some notices for PBX commands data programming are described below. (See Figure 5-1 “Network Configuration of OAI systems” for network configuration of OAI systems.)

I II III

PBX1 PBX2 PBX3 PBX4

Monitor Number Data (AMNO) N/L N

Conversion Number Data (ACNO) N/L N

Announcement/Dictation Data (AADT) N N

OAI Key Code Data (AOKC)

Key Data for Dterm (AKYD)

: Assign data by the corresponding commands written in DM. N : Assign data by the corresponding commands written in NDM. L : Assign data by the corresponding commands written in LDM when the call is not terminated from other nodes.

Type and Node · PBX Command Data

Page 95 of the NEC ND-70895 (E) user manual — 3.7.3 Example of Use of Facility on Fusion Network
Pagina 95 · klik om te vergroten
Pagina 95

OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services

3.7.3 Example of Use of Facility on Fusion Network

As a example of use of facilities through Fusion Network, the explanations will give in the following about Free Location Facility (FLF).

By using Free Location Facility (FLF) through Fusion Network, OAI Logical Number services can be used at any nodes in the Fusion network. This feature is available with the Series 7400 (Release 8) software.

NEC ND-70895 (E) — 3.7.3 Example of Use of Facility on Fusion Network diagram (page 95)
Afb. 30 · 3.7.3 Example of Use of Facility on Fusion Network

OAI Logical Number 5000 is converted from Station Number 200 to Station Number 300

This service enables the Free Location Facility (FLF) beyond the nodes via the Fusion link. For example, if OAI Logical Number 5000 is converted from Station Number 200 at Node A to Station Number 300 at Node B. (Station Number 200 = OAI Logical Number 5000 → Station Number 300 = OAI Logical Number 5000) Information on OAI Logical Number Development is broadcast to all (Fusion network) nodes.

ASYD-SYS1 INDEX 31:06 (Mounting Capacity of Common Memory (CM) 6 Mbytes)

ASYDN-SYS1 INDEX 870, b0=1(FLF Fusion service is available)

ASYDL-SYS1 INDEX 864, b6=1 (FLF Error detailed Information is provided)

Page 96 of the NEC ND-70895 (E) user manual — 3.7.3 Example of Use of Facility on Fusion Network
Pagina 96 · klik om te vergroten
Pagina 96

This page is for your notes.

Page 97 of the NEC ND-70895 (E) user manual — 4. FAULT DIAGNOSIS
Pagina 97 · klik om te vergroten
Pagina 97

CHAPTER 6 MAINTENANCE

This chapter explains maintenance, fault diagnosis out of system messages, fault repair procedure of the NEAX2400 IMX OAI System.

1. General

When a fault has been discovered in the course of maintenance works, the fault is to be diagnosed out of system messages and is to be repaired by the following fault repair procedure (Refer to Figure 6-1).

2. MAINTENANCE

  • Routine Maintenance

System messages indicating OAI fault

3. SYSTEM MESSAGES

  • Message Detail Data

4. FAULT DIAGNOSIS

  • Diagnosis out of System Messages

Figure 6-1 Flow of Maintenance Works

Page 98 of the NEC ND-70895 (E) user manual — SYSTEM MESSAGE FRAME-TOP LAMP
Pagina 98 · klik om te vergroten
Pagina 98

2. Maintenance

2.1 Routine Maintenance

By the routine maintenance on the NEAX2400 IMX OAI System, the following are performed.

1. System messages pertaining to OAI faults

A check is made to see if any system message pertaining to OAI faults is printed out. (Refer to Chapter 6, Section 3.1)

2.1.1 System Messages and Lamp Indications on TOPU

In the OAI system, an alarm lamp on TOPU corresponding to the faulty equipment lights up. The alarm lamps on TOPU corresponding to system messages are shown in Table 6-1.

Table 6-1 Relationship between System Messages and Alarm Lamps on TOPU

SYSTEM MESSAGE FRAME-TOP LAMP

REMARKS No. NAME MJ MN SUP

4-R I/O Card Fault of IP ×

26-V LAN Interface Error Report ×

MAINTENANCE Maintenance

Page 99 of the NEC ND-70895 (E) user manual — 3. System Messages
Pagina 99 · klik om te vergroten
Pagina 99

3. System Messages

3.1 Outline

If any of the NEAX2400 IMX OAI functions becomes faulty, the corresponding system message shown in Table 6-2 is displayed. This section explains the meaning of each system message and message detail data.

Table 6-2 System Messages of OAI System

SYSTEM MESSAGE No. FAULT CONTENTS OF FAULT

4-R TCP/IP Link Failure A fault has occurred to the UAP or to the line connected with the external computer.

26-V LAN Interface Error Report A fault, related to the TCP/IP connection between the PBX and Host, occurred.

MAINTENANCE System Messages

Page 100 of the NEC ND-70895 (E) user manual — (ETHER + TCP/IP)
Pagina 100 · klik om te vergroten
Pagina 100

3.2 Message Detail Data

This paragraph describes the detailed information on the faults indicated by system messages (message detail data).

3.2.1 Message Detail Data of System Message “4-R”

System Message 4-RTCP/IP Link Failure
1. Print-out Format

SYSTEM MESSAGE 4-R TCP/IP Link Failure NEC - ESD DEC 22 21:32

1. xx 2: 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2. Print-out information (typical)

Fault port number: 0-5 Communication Protocol: 03 = ETHER + TCP/IP Error Code (ERRK): Refer to the table below (6-3 ERROR CODE) Fault logical channel number (LCID) : 01~10H (00 means the data is invalid)

Relation between LCID and PBX TCP port number

LCID TCP port number of the PBX

Table 6-3 Error Code

PROTOCOL ERROR CODE CONTENT OF FAULT

01 TCP Connection disconnected (Normal) Note 1

02 Reception of a text that cannot be analyzed Note 2

(ETHER + TCP/IP)

10 (0A) TCP Connection disconnected (On the way) Note 2

11 (0B) Transmission to PZ-PC19 (LANI) is disabled (Permanent) Note 2

12 (0C) Abnormal UAP is detected by Heart Beat function

13 (0D) Not used

14 (0E) TCP/IP Connection Error (B-level Infinite Loop, etc.) Note 2

15 (0F) Not used

message at some offices using SYS1, INDEX864, b1 in ASYDL (Other messages than ERRK = 01 is output when TCP connection disconnected is not output). Note 2: This data is output for Series 7300 Release 6 or earlier. If your system is Series 7300 Release 7 or later, the

message is output by 26-V” instead. (Refer to Section 3.2.2)

Show 4 more labels / short text on this page
MAINTENANCE System Messages · 01 60030 · ~ IP address · 03~09 Not used
Page 101 of the NEC ND-70895 (E) user manual — 3.2.2 Message Detail Data of System Message “26-V”
Pagina 101 · klik om te vergroten
Pagina 101

3.2.2 Message Detail Data of System Message “26-V”

System Message 26-VLAN Interface Error Report (OAI/MIS)
1. Print-out Format

SYSTEM MESSAGE 26-VLAN INTERFACE ERROR REPORT NEC - ESDJULY 25 19:30

TCP/IP PartApplication Part 1: xx 2: xx xx xx 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

2. Print-out information (typical)

~ IP address of the error-detected OAI/MIS terminal ~ Port No. Used socket No. Error Code (TCP/IP part)

Application Type 05 = OAI 07 = MIS (ACD) Faulty Logical Port No. Error Kind (ERRK) 01 = SEND Execution Error 02 = RECEIVE Execution Error 03 = TCP/IP Connection Error 04 = Connection Error (B-level Infinite Loop, etc.) 05 = TCP/IP Port Capacity Over

MAINTENANCE System Messages · -TCP/IP part- · -Application Part-

Page 102 of the NEC ND-70895 (E) user manual — FAULT REPAIR
Pagina 102 · klik om te vergroten
Pagina 102

4. Fault Diagnosis

4.1 General

If a fault occurs to the NEAX2400 IMX OAI System, the corresponding system message is displayed. This section explains the procedures of fault diagnosis by system messages and of fault repairs.

Collection of Fault Information

  • Alarm
  • System Message
  • Fault detected during routine maintenance

Section 4. Item 4.2 Diagnosis from System Messages

FAULT REPAIR

Figure 6-2 Flow of Fault Repair

MAINTENANCE Fault Diagnosis

Page 103 of the NEC ND-70895 (E) user manual — MAINTENANCE
Pagina 103 · klik om te vergroten
Pagina 103

MAINTENANCE

4.2 Diagnosis from System Messages

The flow of works from diagnosis of system message up to discovery of the cause of the fault is shown in Figure 6-3.

Diagnosis from System Message

Identification of Faulty Card, Faulty Equipment

Check the cause of the fault by diagnosing the printed out system messages.

If, during the diagnosis, an alarm such as circuit card initialization, etc., has been indicat- ed, reset (clear) the alarm indication by depressing ALM RST key on the frame-top alarm panel.

If, as a result of the diagnosis, the fault is a temporary one, cancel all alarm indications and release system messages stored in the memory by RALM command and keep watching the system operations thereafter.

Figure 6-3 Flow of Diagnosis out of System Messages

Fault Diagnosis

Page 104 of the NEC ND-70895 (E) user manual — A
Pagina 104 · klik om te vergroten
Pagina 104

4.2.1 TCP/IP Link Failure

For details of System Massage “4-R” and “26-V”, see Section 3.2.1 and 3.2.2 in this Chapter.

START

According to each fault situation, perform the repairing procedure referring to Table 6-4 and Table 6-5.

When Message “4-R” is displayed:

Table 6-4 Repairing Procedure for TCP/IP Link Failure (Message “4-R”)

ERRK Detail information of ERRK Check Item

01 TCP/IP connection is down for the TCP connection disconnection from Host. Re-start the Host

Incorrect text format is received. [1] Check the software operation on the Host side

[2] Check the LAN cable connection

0A TCP/IP connection establishment is not completed for the TCP connection disconnection ordered from Host. Re-start the Host

TCP/IP connection establishment is not completed for the TCP connection disconnection ordered from Host.

[1] Check the TCP/IP transmission capacity on the UAP side is proper or not.

0B

[2] Check the system operation on the UAP side.

0C According to Heart Beat function of Host, abnormal status of the Host system operation is detected. Check system operation of the Host

0E TCP port is released due to the detection of abnormal state in the TCP/IP port (such as B-level Infinite Loop, etc.). Re-check the operation status of Host.

When Message “26-V” is displayed:

Table 6-5 Repairing Procedure for TCP/IP Link Failure (Message “26-V”)

ERRK Detail information of ERRK Check Item

TCP/IP connection is down because the text is not transmit- ted continuously.

[1] Check the TCP/IP Transmission capacity on the UAP side is proper or not.

[2] Check the operation status on the UAP side is normal.

02 Incorrect text format is received. [1] Check the software operation on the Host side.

[2] Check the LAN cable connection status.

03 TCP/IP connection is released due to the TCP port discon- nection order from the Host. Re-start the Host computer.

04 TCP port is released due to the detection of abnormal state in the Host operation. Re-check the operation status of Host.

The number of allowed ports for application use via TCP/IP must be 16 or less. Adjust the total port number within this range.

05 TCP/IP connection cannot be established due to the connec- tion port capacity over.

A

MAINTENANCE Fault Diagnosis · 0D Not used · 0F~FF Not used

Page 105 of the NEC ND-70895 (E) user manual — MAINTENANCE
Pagina 105 · klik om te vergroten
Pagina 105

MAINTENANCE

A

Host is still abnormal status?

Host is out of order. Repair the Host computer.

PZ-PC19 (LANI) card is out of order. For the replacement procedure, See “System Operation and Maintenance Manual”.

Fault Diagnosis · If yes, · If no,

Page 106 of the NEC ND-70895 (E) user manual — 4.2.1 TCP/IP Link Failure
Pagina 106 · klik om te vergroten
Pagina 106

This page is for your notes.

Vraag stellen over de NEC ND-70895 (E)

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de NEC ND-70895 (E)

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

NEC ND-70895 (E) handleiding-pdf

106 pagina's·1.4 MB·Seniorentelefoon·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…