Gebruiksaanwijzing /service van het product 10 HP van de fabrikant Oneida Air Systems
Ga naar pagina of 24
10 HP NYB Pulley/Belt Drive Cyclonic Dust Collectors Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .
Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection.
O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely: A.) Seal ductwork with silicone sealant or duct tape.
II. 10hp Pulley Drive Configurations 1. No Filter - V ent Outside - Caution: If exhaust air is vented outside you must provide make up / return air . Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances.
III. General Specifications & Fan Per formance Cur ves 4 10hp Fan Cur ves O.A.S. 2007 c 10 HP Industrial Systems Owner s Manual Full welded exterior Main body , cone and inlet: 16 ga. galv . Flanged 12 dia. Inlet; Flanged 13 dia. Outlet 80 high 14 rolled steel flange discharge 36 dia.
IV . Dimensions 5 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual T op V iew Dimensions - Largest Configuration 1 1/2 Flange w/ Bolt Holes 34 10hp - 229 14 10hp - 83 30 42 17 80 Approx. 18 36 14 39 36 8 39 32.
IV . Dimensions 6 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual - External Cartridge Filters 17 80 Approx. 18 36 10 14 14 39 10hp - 3 filters -Single Row - 66 36 29 1/8 8 39 62 12 55 Gal.
7 O.A.S. 2007 c 10HP Pulley Drive Owner s Manual C-3500 Cyclone Stand - Anchor Feet Securely to Floor to Prevent Tipping (4) 3/8-16 x 1 bolts for Cyclone mount (20) 3/8-16 x 1 bolts for Cross.
V . Configuration Examples Sleeve Kit - Sleeve-Kit 14 for C-2500 cyclone requires 16 - 18 for a single drum and 24 for 2x drums. Additional feet of flex can be purchased to make the sleeve kit longer if needed. Drum - S tandard 55 gal. steel drums are usually 35 - 36 high Oneida Air sells 55 gal.
VI. General Assembly Instructions 9 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 1. Determine mounting height for the cyclone. - Height depends on size of Dust Bin and length of Flex Hose to Dust Bin connection. 2. Mount Angle Iron Brackets to wall using included hardware.
VI. General Assembly Instructions 10 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 7. Set up Fan/Blower (Cont.) All moving part s must have guards to protect personnel. Safety requirement s vary , so the number and type of guards needed to meet company , local and OSHA standards must be determined and specified by the user .
5 gallon buckets 12 high (Not supplied with system). Can be purchased, Part No. SDS050000 or recycled joint compound bucket s or food storage containers can be used.
XII. Fan / Blower Wiring Diagram Wiring should always be done by a licensed electrician! 10 HP Pulley Drive Owner s Manual O.A.S. 2007 c Before Operation - Before making electrical power connections, check for proper grounding of motor and application.
IX . Fan / Blower - Maintenance The Fan / Blower has a TEFC - tot ally enclosed fan cooled motor that can be placed outside. The fan housing is adjustable by 22 1/2 degree increment s - outlet can be oriented by adjusting bolt hole locations between the scroll and the bracket assembly .
14 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Maintenance of Fan / Blower (Cont.) 2.) Cleanliness - Keep both the interior and exterior of the motor free from dirt, water , oil and grease. 3.) Safety - Motors should be installed, protected and fused in accordance with latest issue of National Electrical Code, NEMA S tandard Publication No.
X . Accessories O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Dust Bin Options - (Must Order Custom Cyclone Mounting S tand.) 2. Hoppers - Large capacity hoppers from .
XII. Troubleshooting Motor Overheating The motor s internal circuit breaker will trip if the motor is overheating. Air leaks between the collector and dust bin - The lid of the dust bin and the cyclone must be in place and sealed when operating the dust collector .
XII. Fire Hazards - Read Before Installing and Operating 17 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector .
XIII. T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt.
The External Filter can be cleaned using the following methods: W ait a few minutes for internal dust to settle then unclip and carefully empty dust bin. XIV . Directions for Cleaning External Filter Keep nozzle at least 6 from filter and keep your pressure down.
O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 20 XV . Filter Efficiency Gauge Mounting Instructions Can be attached up to 8 away . OR Air Flow to Filter Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream.
O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 21 P le as e se e comp l ete m an ufa ct u rer i ns t ruc t i o ns for mo re i nfo r m at i on. T h is supplement i s des i gn ed to aid Oneida A ir Systems cu stomers with frequentl y as k e d ques t ions.
O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 22 Open ac ces s cover on the over load, th en s e t t h eo v e r l o a da m p e r a g ed i a lt om a t c ht h eF L A amperage of your motor . Th e FLA v alue can be fo und o n y our mot or name pla te.
O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 23 L3 L2 L1 A1 21 13 T3 T2 T1 A2 22 14 M T3 T2 T1 96 L3 L2 L1 95 98 97 OL / SC T3 T2 T1 7 4 1 8 5 2 9 6 3 White Yel lo w Bro wn Pl ug - I n C onn ector Res et I nstall th is Ju mper fo r Sing le O Usi ng the Sa me Gaug e Wir e S i ze d & Co nnec te d t o L 1 & L2.
Een belangrijk punt na aankoop van elk apparaat Oneida Air Systems 10 HP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Oneida Air Systems 10 HP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Oneida Air Systems 10 HP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Oneida Air Systems 10 HP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Oneida Air Systems 10 HP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Oneida Air Systems 10 HP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Oneida Air Systems 10 HP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Oneida Air Systems 10 HP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.