Powerware 9125 Two-in-One UPS 2500/3000 VA User’s Guide ®.
Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with th e limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm ent.
Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standa rds and EU directives: S Harmonized Standards: EN 50091 - 1 - 1 and EN 50091-2;.
Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com i Table of Contents 1 Introduction 1 ......................................................... 2 Safety Warnings 3 ...............................
TABLE OF CONTENTS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com ii 7 UPS Maintenance 51 .................................................... UPS and Battery Care 51 ...........................
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 1 Chapter 1 Introduction The Powerware ® 9125 uninterruptible power system (UPS) protects your.
INTRODUCTION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 2 S Start - on - battery capability for powering up the UPS even if utility power is not available.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 3 Chapter 2 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions t hat you should follow during installation and maintenance of the UPS and batteries.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 4 CAUTION S Batteries can present a risk of electrical s hock or burn from high short-circuit current. Observe proper precautions.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 5 ADVARSEL S Batterier kan udgøre en fare for elektrisk stød eller forbrændinger forårsaget af høj kortslutningsspænding. De korrekt e forholdsregler bør overholdes.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 6 OPGELET S Batterijen kunnen gevaar voor elektrische sc hok of brandwonden veroorzaken als gevolg van un hoge kortsluitstroom. Vol g de desbetreffende aanwijzingen op.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 7 Consignes de sécurité CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES CONSIGNES DE SÉCURITÉ IMPORTANTES DANGER! Cet onduleur contient des TENSIONS MORTE LLES.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 8 Sicherheitswarnungen WICHTIGE SICHERHEITSANWEISUNGEN AUFBEWAREN Dieses Handbuch enthält wichtige Hinweise, welche Sie bei der Installation und Wartung die USV beachten sollten.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 9 VORSICHT! S Batterien können aufgrund des hohen Kurz schlußstroms Elektroschocks oder Verbrennungen verursachen. Die entspre chenden Vorsichtsm aßnahmen sind unbedingt zu beachten.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 10 ATTENZIONE S Le batterie possono presentare rischio di sco ssa elettrica o di ustioni provocate da alta corrente dovuta a corto circuito.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 11 Regulamentos de Segurança INSTRUÇÕES DE SEGURANÇA IMPORTANTES GUARDE ESTAS INSTRUÇÕES ESTE MANUAL CONTÉM INSTRUÇÕES DE SEGURANÇA IMPORTANTES CUIDADO A UPS contém VOLTAGEM MORTAL.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 12 Предупреждения по мерам безопасности ВАЖ.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 13 Advertencias de Seguridad INSTRUCCIONES DE SEGURIDAD IMPORTANTES GUARDE ESTAS INSTRUCCIONES ESTE MANUAL CONTIENE INSTRUCCIONES DE SEGURIDAD IMPORTANTES PELIGRO Este SIE contiene VOLTAJES MORTALES.
SAFETY WARNINGS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 14 Säkerhetsföreskrifter VIKTIGA SÄKERHETSFÖRESKRIFTER SPARA DESSA FÖRESKRIFTER DENNA BRUKSANVISNING INNEHÅLLER VIKTIGA SÄKERHETSFÖRESKRIFTER FARA Denna UPS-enhet innehåller LIVSFARLIG SPÄNNING .
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 15 Chapter 3 Installation This section explains: S Equipment inspection S UPS internal battery .
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 16 Connecting the UPS Internal Battery To ensure proper battery operation before installing the UPS: 1. Verify that the UPS is off and unplugged.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 17 Rack-Mount Setup The UPS can be installed in 19 - inch racks and needs only 2U of valuable rack space. CAUTION The UPS and EBM are heavy (see page 61).
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 18 NOTE The EBMs must be installed below the UPS as shown in Figure 6. 5. Slide the UPS and any optional EBMs into the rack. 6. Secure the cabinets to the rack according to the rail kit instructions.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 19 Figure 7. Installing UPS Pedestals (for One Cabinet) 4. Carefully position the cabinet upright with the air vents at the top (see Figure 8).
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 20 7. Place the EBM cabinet upside down so that the right end of the cabinet is accessible (see Figure 10). Figure 10. Installing EBM Pedestals 8.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 21 NOTE Pedestals are required for installations wi th one or two cabinets. Joining brackets are required for installations with two or more cabinets.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 22 Extended Battery Module Installation CAUTION A small amount of arcing may occur when connec ting an EBM to the UPS. This is normal and will not harm personnel.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 23 4. E/EH UPS models have a battery connector cover that must be removed before installing the EBM(s). Remove the cover from the rear panel as shown in Figure 15.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 24 6. Plug the EBM cable into the UPS battery connector (see Figure 17). 7. Attach the fixed cover plate (supplied in the accessory kit) to the EBM cable as shown in Figure 17.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 25 Plug-Receptacle UPS Installation NOTE Do not make unauthorized changes to the UPS or accessories; otherwise, damage may occur to your equipment and void your warranty.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 26 4. For 208/230V models only. Plug the detachable UPS power cord into the input connector on the UPS rear panel. 5. Plug the UPS power cord into a power outlet.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 27 Hardwired UPS Installation WARNING Only qualified service personnel (such as a licensed electrician) shall pe rform the electrical installation.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 28 To hardwire the UPS: 1. If you are installing power management software, connect your computer to the UPS communication port using the supplied communication cable.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 29 5. Insert each conduit through a wiring access entry and attach the conduit fitting to the panel. Strip 1.5 cm (0.5 I ) of insulation from the end of each incoming wire.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 30 10. Switch the main utility breaker on.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 31 Remote Emergency Power-off Installation The Powerware 9125 includes a REPO port that allows power to be switched off at the UPS output from a customer - supplied switch in a remote location.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 32 3. Connect isolated, normally - closed, dry contacts (rated to handle 60 Vdc maximum, 30 Vac RMS maximum, and 20 mA maximum) across the REPO device to Pin 1 and Pin 2 (see Figure 24).
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 33 UPS Rear Panels This section shows the rear panels of the Powerware 9125 models.
INSTALLATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 34 Communication Port Terminal Block REPO Port Battery Connector Network Transient Protector X-Slot Communication Bay Figure 28.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 35 Chapter 4 Operation This section describes: S Turning the UPS on and off S Starting the UPS .
OPERATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 36 Turning the UPS Off NOTE Pressing the Off button while the UPS is in Battery mode causes the UPS to shut down immediately. To turn off the UPS: 1.
OPERATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 37 Operating Modes Powerware 9125’s front panel indicates the UPS status through the UPS indicators. Figure 30 shows the UPS front panel indicators and controls.
OPERATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 38 Normal Mode During Normal mode, the μ indicator illuminates and the front panel displays the percentage of UPS load capacity being used by the protected equipment (see Figure 31).
OPERATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 39 Battery Mode When the UPS is operating during a power outage, the alarm beeps once per second and the + --- indicator illuminates. The front panel displays the approximate percentage of battery capacity remaining (see Figure 32).
OPERATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 40 Bypass Mode In the event of a UPS overload or internal failure, the UPS transfers your equipment to utility power. Battery mode is not available; however, the utility power continues to be passively filtered by the UPS.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 41 Chapter 5 Configuration When the UPS is in Configuration mode, the bar graph indicators represent the configuration options. Use the control buttons (On button and button) to modify the UPS configuration.
CONFIGURATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 42 1 Press and hold the On and Test/Alarm Reset buttons simultaneously to toggle between Configuration and Operation modes. & 4 Press the Test/Alarm Reset button to select an option.
CONFIGURATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 43 Table 2. Configuration Mode LEDs and Options Configuration Mode LEDs Option LE.
CONFIGURATION EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 44.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 45 Chapter 6 Additional UPS Features This section describes: S X - Slot cards S Network transie.
ADDITIONAL UPS FEATURES EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 46 Multi-Server Card Relay Interface Card USB Card Modbus Card ConnectUPS-X Web/SNMP Card X-Slot Communication Bay (Single-Port Card shown) Figure 34.
ADDITIONAL UPS FEATURES EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 47 Table 3. Communication Port Pin Assignment Pin Number Signal Name Fu.
ADDITIONAL UPS FEATURES EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 48 On-Bypass Relay Jumper (J3) On-Bypass Disabled On-Bypass Enabled AS/400 NORM Figure 37. On-Bypass Relay Jumper 3. To prevent electrostatic discharge (ESD), place one hand on a metal surface such as the UPS rear panel.
ADDITIONAL UPS FEATURES EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 49 Network Transient Protector The network transient protector, shown in Figure 38, is located on the rear panel and has jacks labeled IN and OUT.
ADDITIONAL UPS FEATURES EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 50 Load Segments Load segments are sets of receptacles that can be controlled by power management software, providing an orderly shutdown and startup of your equipment.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 51 Chapter 7 UPS Maintenance This section explains how to: S Care for the UPS and batteries S R.
UPS MAINTENANCE EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 52 When to Replace Batteries When the indicator flashes, the batteries may need replacing. Conduct a self - test by pressing and holding the button for three seconds.
UPS MAINTENANCE EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 53 How to Replace UPS Internal Batteries CAUTION Pull the battery out onto a flat, stable surface. The battery is unsupported when you pull it out of the UPS.
UPS MAINTENANCE EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 54 4. Unscrew and set aside the battery retaining bracket (see Figure 43). Battery Retaining Bracket Figure 43. Removing the Battery Retaining Bracket 5.
UPS MAINTENANCE EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 55 How to Replace Extended Battery Modules CAUTION The Extended Battery Module (EBM) is heavy ( see page 61). A minimum of two people are required to lift the EBM when it is replaced.
UPS MAINTENANCE EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 56 UPS Battery Connector EBM Battery Connectors Joining Brackets EBM Cables Figure 45. EBM Connections (120V UPS Model Shown) Testing New Batteries Press and hold the button for three seconds to initiate a self - test.
UPS MAINTENANCE EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 57 Recycling the Used Battery or UPS Contact your local recycling or hazardous waste center for information on proper disposal of the used battery or UPS.
UPS MAINTENANCE EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 58.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 59 Chapter 8 Specifications This section provides the following specifications: S Model list S Electrical input and output S Weights and dimensions S Environmental and safety S Battery Table 4.
SPECIFICATIONS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 60 Table 5. Power Connections M d l I t C t i Output Connections Model Inpu t Co.
SPECIFICATIONS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 61 Table 7. Weights and Dimensions UPS Extended Battery Module Dimensions (WxDxH) 43.2 × 60.7 × 8.9 cm 17.0 ” × 23.9 ” × 3.
SPECIFICATIONS EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 62 Table 9. Battery UPS Configuration (6) 12V, 9 Ah internal batteries EBM Confi.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 63 Chapter 9 Troubleshooting This section explains: S UPS alarms and conditions S H o wt os i l.
TROUBLESHOOTING EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 64 Table 11. Troubleshooting Guide Alarm or Condition Possible Cause Action The indicator is not on; the UPS does not μ The power cord is not connected correctly.
TROUBLESHOOTING EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 65 Action Possible Cause Alarm or Condition Shutdown - Low Battery Shutdown imminent. Prepare equipment for shutdown. Bypass The UPS is in Bypass mode.
TROUBLESHOOTING EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 66 Service and Support If you have any questions or problems with the UPS, call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a UPS technical representative.
EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 67 Chapter 10 Warranty Two-Year Limited Warranty (US and Canada) Powerware UPS Models: 3105, 3110, 3115, 9104, 9120, 9125, and FERRUPS ® up to 3.
WARRANTY EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 68 WHAT THIS LIMITED WARRANTY DOES NOT COVER: This Warranty does not cover any defects.
WARRANTY EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 69 COSTS NOT RELATED TO WARRANTY: The End-User shall be invoiced for, and shall pay fo.
WARRANTY EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 70 WHAT THIS LIMITED WARRANTY DOES NOT COVER: This Warranty does not cover any defects.
WARRANTY EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 71 OTHER LIMITATIONS: Company’s obligations under this Warranty are expressly conditioned upon receipt by Company of all payments due to it (including interest charges, if any).
WARRANTY EATON Powerware ® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com 72 WHAT THIS GUARANTY DOES NOT COVER: Any reimbursement or repair to End - User’s equipment does not include reimbursement for or restoration of any data l oss.
Een belangrijk punt na aankoop van elk apparaat Powerware 2500 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Powerware 2500 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Powerware 2500 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Powerware 2500 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Powerware 2500 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Powerware 2500 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Powerware 2500 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Powerware 2500 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.