Protect the machine from frost and rain. With temperatures below zero, the valves can freeze to the pump which may cause damage to both motor and pump. Notice: insufficient air supply, too high temperature and fouling of the air filter reduce the efficiency of the compressor considerably. 3.1 ELECTRIC CONNECTION L/LM/KM/BLM At the factory the machine is already fully equipped with cables. The machine now has to be connected to your own electricity supply. Beware that voltage and amperage of your electric circuit meet the needs of the motor. For that check technical details. Use only cables with the right diameter. The factory advises to use cables of at least 2,5 qmm. Before first use first read chapters 3.2 and 4.0. 3.2 AIR CONNECTION The compressor is equiped with an air reduction/filter combination with two closable air connectors (except type L 5-90). Best use for connection of the compressor to an air circuit a flexible hose, to isolate fibrations from the machine. The diameter of the hose must meet the diameter of the air connection on the compressor. For quickly attaching and unattaching of hoses and pneumatic tools it is well advised to use quick-couplings. 4.0 FIRST USE 1 Check if the instructions mentioned above have been executed. 2 Check the oil level of the compressor. Possibly oil has been lost during transport. The oil level has to be between the upper side of the oil level glass (12) and the red dot. If necessary, fill with AIRPRESS compressor oil. 3 V-belt models: check the tension on the V-belt. At the right tension the V-belt can easily be turned by hand approximately 45 degrees. If necessary improve tension (see chapter 6.0 point 5). 5.0 L, LM AND KM COMPRESSORS 5.1 FUNCTIONING When the pressure switch (2) is turned on at an air pressure of 0 bar/psi, the motor (8) will start. The motor is directly connected to an one, two or three cylinder pump (11). When a specific pressure has been achieved, the pressure switch automatically stops the motor and relieves the internal air circuit from pressure. When air is being used, pressure will drop. When low enough, the pressure switch will start the compressor again automatically. With the reduction valve (5) you can reduce a too high air tank pressure to a desired working pressure. The step less adjustable pressure can be read from a

pressure gauge (4). The reduction/filter combination also cleans air from oil and water drops. L and LM types: In the connection box (9) at the motor, a thermal protection has been attached. This device turns off the compressor automatically, to protect the motor from overheating. By pressing the red reset button (10) at the bottom of the box after a little time, the compressor is ready to function again (type LM 100-400 has the thermal protection device on top of the motor). KM types: The 400 volts electric motor of your compressor is protected against overheating by a combined switch + reset button (2). This device turns off the motor automatically if the motor should get overloaded or if one phase should fall out. By pressing the black reset button after a short time, the compressor will function again. If repeating thermal failure should occur, see chapter 7.0 Possibilities of failure. 5.2 OPERATING Check if the pressure switch has been set off. Then connect the machine to your electric circuit. Set the pressure switch to on. If the pressure in the air tank is below the pressure to start the machine, the compressor automatically will start until the pressure to stop the machine has been reached. If the pressure is high enough, the compressor will not start but will remain stand-by until pressure drops below the point to start the machine. To accomplish a continuous working pressure, the machine is equipped with a reduction valve. With this device, you can reduce the air tank pressure to any desired working pressure. Therefore, pull the button out of the interlocking and turn left for a lower pressure and right for a higher pressure. Of course, the working pressure can never be higher than the air tank pressure. Turning off your compressor, you should always first turn the pressure switch off before you pull out the plug. This way the pressure switch relieves the air from the internal air circuit, so that the compressor can run freely when it is to be turned on again. This protects the motor from damage.


Model L 5-90 LM 15-350 LM 25-220 LM 50-220 BLM 15-220 BLM 15-350 BLM 20-350
Motor (HP/kW) 1,0/0,75 2,5/1,8 1,5/1,1 1,5/1,1 1,5/1,1 2,5/1,8 2,5/1,8
Air tank (ltr.) 5 15 25 50 15 15 20
Stages 1 Working pressure (bar) 14 8 Max. pressure (bar) 16 10
Weight (kg) 15 40 55 65 52 52 50
Voltage 230 230 LM 230 LM 230

Model LM 50-350 KM 50-350 LM 100-220 LM 100-350 KM 100-350 LM 100-400
Air tank (ltr.) 50 50 100
Stages 1 Working pressure (bar) 8 Max. pressure (bar) 10
Modelchanges reserved. All compressors are provided with Euro-norm (CE-choise).

6.0 BM 50-400 and DM 50-330 The BM 50-400 and the DM 50-330 can deliver compressed air wherever it is needed, thanks to their reliable fuel engine. Placing instructions are similar to the normal electric models. However, you should realise that the fuel engine produces poisoness smoke. So let it run only outdoors or in a heavy ventilated room. Further details you will find in the safety instructions that go with the engine. 6.1 FUNCTIONING The fuel engine drives the pump by a V-belt. In peristaltic moves, the cylinders press air through a cooler into the air tank. A non-return valve with a clearance valve (20) is mounted on the air tank. As long as the air tank pressure is below the pressure to turn off the machine (10 bar), the pump presses the air into the air tank through the non-return valve. When the right pressure has been reached, the clearance valve will open. When pressure drops again, the clearance valve will close and air will be pressed into the tank again. 6.2 OPERATING Notice: before starting, first read the instruction manual of the fuel engine. Starting procedures are as follows: - make sure that the air tank is empty - open the fuel cock - open gas handle for one-third - with cold engine: choke closed - with hot engine: choke half opened - pull starting wire gentle until some tension can be felt - then pull wire firmly (not entirely to the end) - let the engine run freely until it’s warm (several minutes) - shift gas handle further open The pump is now running and building up pressure in the tank. If the right pressure has been reached, the clearance valve will open and air will run away. At this point the gas handle can be shifted back. It is well advised not to let the engine run faster than strictly needed for delivery of air. In that way, you prevent the machine from long periods of running freely unnecessary and you save fuel. To stop the compressor, you only need to close the fuel cock or press the stop button. You will find more details in the instruction manual of the fuel engine.

6.3 TECHNICAL DETAILS Model BM 50-400 DM 50-330 Motor (HP) 5,5 5 Fuel petrol diesel Air tank (ltr) 50 50 Number of cylinders 3 2 Number of stages 1 1 Working pressure (bar/psi) 8 8 Max. pressure (bar/psi) 10 10 Suction capacity (ltr/min.) 400 330 Weight (kg) 70 70 7.0 MAINTENANCE Before carrying out any maintenance jobs it is obligatory to stop the machine and disconnect it from the power mains by pulling out the plug. 1 After the first 50 operating hours and then every 250 operating hours the oil should be refreshed. Therefore, turn out the oil refill cap (7). Then turn out the oil drain plug (13) and collect the old oil. If no oil runs out, turn in the oil drain plug (13) and fill with fresh oil through the oil refill cap (7). The right oil level is between the top of the oil level glass (12) and the red dot on the glass. Always respect the regulations in force for disposing of old oil and other polluting materials! 2 Regularly drain condensation water. The drain tap is situated at the bottom of the tank. Draining with pressure in the tank is the easiest way. Condensate must be disposed of in conformity with the local regulations in force (not in the sewer!). As an alternative you can place an oil/water separator. 3 The oil level should also be checked regularly. The oil level must be between the top of the oil glass and the red dot on it. If necessary refill with AIRPRESS compressor oil (11). Checking daily can prevent a lot of troubles! Use oil of the same type as that already in the machine; do not mix different types of oil! 4 The air filter element should be cleaned or changed regularly. This change depends on the amount of fouling and should be done more often in dusty situations and less often in a clean situation. For cleaning the filter element, take out the filter container with the filter. Then clean the filter by blowing off the dust.

5 The V-belt should be checked after every 1000 hours. At the right tension, the V-belt can easily be turned 45 degrees by hand. If tension is too high, strong corrosion will occur or eventually the spindle of motor or pump may break. At too little tension, the efficiency of the compressor decreases considerably. Tightening the V-belt goes as follows: Dismount the belt protector (3). Unscrew the fastening bolts on the motor sledge. Remove the V-belt. Place the motor at the wright distance from the pump. Make sure that the pulley of the motor runs in the same line parallel with the flywheel on the pump (see drawing). Tighten the fastening bolts and replace Motor Pump the V-belt. Worn V-belts should pulley pulley be replaced by new ones with the same size. 6 Before maintenance of the fuel engine, first read the instruction manual of the fuel engine. Note: Regular maintenance of your compressor will increase durability and reliability.

1 air filter 8 safety valve 2 motor 9 pressure switch 3 and 5 cylinder 10 pressure gauge 6 after cooler 11 air tank 7 non return valve 7.2 MAINTENANCE TABLE works daily weekly every every
250 hours 1000 hours draining condensation water ▀
check oil level ▀
clean air filter ▀
refresh oil (first time after 50 hrs) ▀
check V-belt ▀

8.0 POSSIBILIBIES OF FAILURE 1 When pushing the pressure switch the compressor does not run: * blown fuse - renew the fuse * tank at pressure * loose wire - repair * motor broken - repair/renew * thermal failure - reset thermal relay (see point 2) * defective pressure switch - repair/renew ° defective condensator - renew 2 Repeating thermal failure: * pressure switch does not releave - repair/renew valve air circuit * too low voltage - remove extension cable or use heavier § phase out of order - renew fuse * overloading - reduce loading 3 Compressor keeps blowing off air: * defective non-return valve - repair/renew 4 Too little air production: * dirty air filter - clean/renew filter * defective valves - renew # V-belt too loose - tighten V-belt 5 Leaking safety valve: * pressure too high - set pressure switch * defective safety valve - renew * general failures ° failures only with L and LM types (230 volt) § failures only with KM types (400 volt) # failures only with LM 100-400, BM 50-400 and DM 50-330 Problem shooting for the engines of the BM 50-400 and the DM 50-330 is to be found in the instruction manual of the fuel engine.