NL
Honda logo
Officiële handleiding

Honda ESE 604

80 pagina's·1.6 MB·Generator·PDF·ENJA
Honda ESE 604
Inhoudsopgave 32 secties GB..............................13 · E.................................25 · P.................................31 · NL...............................37 · … TonenVerbergen
Page 1 of the Honda ESE 604 user manual — E
Pagina 1 · klik om te vergroten
Pagina 1

GB 13

E.................................25

P.................................31

NL...............................37

DK...............................43

N..................................49

S..................................55

G..................................61

SF................................67

RU................................73

I..................................1

F.................................7

D................................19

MANUALE DI USO E MANUTENZIONE

MANUEL D ’ UTILISATION ET D ’ ENTRETIEN

USE AND MAINTENANCE MANUAL

ANLEITUNG FÜR GEBRAUCH UND WARTUNG

MANUAL DE USO Y MANTENIMIENTO

INSTRUÇÕES DE UTILIZAÇAÕ E DE MANUTENÇAÕ

ADVIÉZEN VOOR GEBRIUK EN ONDERHOUD

BRUGERVEJLEDNING OG VEDLIGEHOLDELSESVEJLEDNING

BRUK-OG VEDLIKEHOLDSANVISNING

BRUKSANVISNING OCH SKÖTSEL

KÄYTTÖ-JA HUOLTO-OHJE

ɂɇɋɌɊɍɄɐɂɘ ɉɈ ɂɋɉɈɅɖɁɈȼȺɇɂɘ ɂ ɌȿɏɇɂɑȿɋɄɈɆɍ ɈȻɋɅɍɀɂȼȺɇɂɘ

GENSET ESE

diesel / silent

C M Y CM MY CY CMY K

C.G.I. MODERNOGRAFICA s.r.l. - codG005420 - Rev. 03

Endress power products Gmbh

Nürtinger Str. 83

Phone0049 (0) 7022 2440 -0
Fax0049 (0) 7022 2440 -10

E

D

P

A

P

E

R

E

R

A

A

T

R

A

T

A

R

Show 6 more labels / short text on this page
Componenti · Tabella Componenti · Lista Targhette · D- 72663 Großbettlingen · % · %
Page 2 of the Honda ESE 604 user manual — GB..............................13
Pagina 2 · klik om te vergroten
Pagina 2
Honda ESE 604 — GB..............................13 diagram (page 2)
Afb. 1
Page 3 of the Honda ESE 604 user manual — KEEP FOR FUTURE REFERENCE
Pagina 3 · klik om te vergroten
Pagina 3

GB

CONTENTS (1.1): Safety instructions pag. 13 Preliminary checks pag. 13 Starting the generator pag. 14 Using the generator pag. 15 Stopping the generator pag. 15 Maintenance pag. 16 Cleaning pag. 16 Transportation pag. 16 Storage pag. 16 Trouble shooting pag. 17

  • INTRODUCTION (2.2): Thank you for purchasing one of our generator sets. We would like to draw your attention to a few points concerning this manual:
  • This manual gives useful indications for the correct use and maintenance of the generator set to which it refers. It is therefore indispensable to pay the fullest attention to all those paragraphs illustrating the simplest and safest way of using the generator set.
  • This manual is to be considered as an integral part of the generator set and must be included at the moment of purchase.
  • This publication may not be reproduced, either totally or in part, without written authorization from the manufacturers.
  • All information shown hereafter is based on the data available at the moment of printing; the manufacturers reserve the right to make modifications to their products at any time, without notificarion and without incurring sanctions. It is therefore advisable to check for any updates.

KEEP FOR FUTURE REFERENCE

USE OF THE MACHINE •THE GENERATOR SET IS DESIGNED TO SUPPLY THREE PHASE AND/OR SINGLE PHASE ELECTRICAL POWER.

Honda ESE 604 — KEEP FOR FUTURE REFERENCE diagram (page 3)
Afb. 2
  • THE MOTOR WELDING SET IS DESIGNED TO SUPPLY THREE PHASE AND/OR SINGLE PHASE ELECTRICAL POWER OR FOR ELECTRIC ARC WELDING WITH COATED ELECTRODES.
  • NO OTHER APPLIANCES OTHER THAN THOSE INDICATED SHOULD BE USED.
  • ISAFETY INSTRUCTIONS (4.2): WARNING: Failing to observe the following instructions may cause injury to persons and animals and/or damages to things. The Manufacturer declines any responsibility for improper use.
  • Do not run the generator set in closed work areas: the engine produces carbon monoxide and other harmful gases detrimental to the health of persons who work with it; make sure that the generator set is well ventilated.
  • Direct combustion exhaust gas outside the machine room or a reasonable distance away from the workplace and personnel. Use piping or other extraction methods.
  • The generator set must only be run on a horizontal surface to guarantee optimum oil and fuel flow to the engine. If it is not possible to run it on a horizontal surface, provide the necessary means to anchor and level the engine for assuring the machine’s stability.
  • In case of use during rain or snow, make sure that the generator set is well and firmly sheltered.
  • Always keep children away from the generator set when in use. Remember that, even after being powered off, the engine will remain at a high temperature for about 1 hour. The areas where the exhaust pipe, the exhaust hoses and the engine are placed are subject to high temperatures and could cause severe burns if touched.
  • Do not carry out maintenance and servicing when the generator set is working: always stop the engine.
  • Refuelling and topping up with oil must be done when the engine is not running; remember that the engine remains hot for about 1 hour after it is turned off.
  • It is essential to be aware of the functions and controls of the generator set: do not allow any unauthorized persons to use the machine.
  • Improper use of the machine should be avoided, such as using the engine to heat the surrounding atmosphere etc.
  • Do not allow any unauthorized persons to use the machine. To make sure the generator set cannot operate, block the system - remove the starter key, close and lock the cowling.
  • The machine does not need to be in a specially lighted area. However provide adequate lighting in compliance with the norms in force.
  • Do not remove the protection devices and do not use the machine without adequate protection (sides and casing) to avoid risks for the user.
  • Should it be necessary to remove the protection devices (for maintenance or servicing), this operation should be done with the generator set switched off and only by specialized personnel.
  • Do not use the machine in an explosive atmosphere.
  • In case of emergency do not use water to extinguish a fire, use only suitable equipment (a powder loaded fire extinguisher, etc.).
  • Whenever it is necessary to work in close proximity to the machine, sound mufflers should be used (head muffs, ear plugs, etc.).
  • The welding electric arc emits ultraviolet radiation which can injury eyes and burn the skin. Wear a welding mask with adiactinic screen and suitable protective clothes.
  • Sparks at hundreds of °C are produced during welding and can be thrown several metres away. Be very careful not to run the machine – even when it is used as a generator set – next to containers of flammable substances and/or in explosive atmospheres. WARNING: Avoid any direct bodily contact with fuel, motor oil or battery acid. In case of contact with the skin wash with water and soap and rinse thoroughly; do not use organic solvents. In case of contact with the eyes, wash with water and soap and rinse thoroughly. In case of inhalation or swallowing, consult a medical practitioner.
  • PRELIMINARY CHECKS (5.2):
  • Make sure these operations are carried out with the generator set placed on a horizontal and stable surface.
  • Oil (provide for filling) is the most important element influencing the efficiency and long life of the engine. In the operation and maintenance manual are shown details of the type of oil to use and the correct oil level for this generator set. WARNING: Running the engine with insufficient oil could cause serious damage.
  • Check the fuel level: use clean fuel free of water. WARNING: Fuel is highly inflammable and explosive under certain conditions. Refuel in a well ventilated area with the engine switched off. Do not smoke and do not approach the equipment with an open flame while refuelling. Do not overfill the tank – i.e do not fill up to the cap-, as engine vibrations could cause fuel spillage. Pay attention not to spill fuel while filling the tank. Make sure that the cap is correctly screwed down after filling. If fuel has been spilt, make sure that the area is completely dry before switching on the engine. Avoid any bodily contact with the fuel and do not inhale the vapour. Keep the fuel out
Page 4 of the Honda ESE 604 user manual — GB
Pagina 4 · klik om te vergroten
Pagina 4
  • of children’s reach. Fuel fumes are highly inflammable.
  • Check the air filter: make sure that it is in good conditions and free from dust and dirt. To reach the filter consult the engine use and maintenance manual. WARNING: do not use the generator without the air filter: the life of the engine and of the generator set will be reduced!
  • Activate the battery (if supplied): fill the compartments to their maximum level with a 30/40% sulphuric acid solution and wait at least two hours before using.
Battery locationsee fig. 1, 2 and 3
Honda ESE 604 — GB diagram (page 4)
Afb. 3
Honda ESE 604 — GB diagram (page 4)
Afb. 4
Honda ESE 604 — GB diagram (page 4)
Afb. 5

Fig.1 (Yanmar L48 e L70) Fig.2 (Honda e Yanmar L100) Fig.3 (Ruggerini)

  • STARTING THE GENERATOR SET (6.4): Before starting the machine it is necessary to:
  • Make sure that no appliance is plugged into the generator.
  • HONDA engine models: activate the choke on the control panel for cold starts.
  • How to start:
  • Electric start generators: turn the key onto “START” position and release it as soon as the engine starts.
  • Recoil start generators YANMAR engine):
1. Set the accelerator control – placed on the engine (see fig. 4) – downwards (max rpm). 2) Lower the valve lifter lever placed on the engine, as shown in figures 5 and 6. 3) Pull the recoil handle gently until resistance is felt, then pull forcefully.
Honda ESE 604 — GB diagram (page 4)
Afb. 6
Honda ESE 604 — GB diagram (page 4)
Afb. 7
Honda ESE 604 — GB diagram (page 4)
Afb. 8

Fig.5 (Yanmar L48 e L70) Fig.6 (Yanmar L100) Fig.4

  • Once the engine is started, take back the lever to its original position.
  • The generator set is now ready for use.

NOTE: If the generator set is used at high altitudes or temperatures, the air-fuel mixture ratio may be too rich. This will cause higher consumption and lower performance. Check the actual power of the generator set by means of the following correction factors: TEMPERATURE: Power drops an average of 2% every 5 degrees centigrade above a temperature of 20 degrees centigrade. ALTITUDE: Power drops an average of 1% every 100 metres a.s.l. Above an altitude of 2000 m, contact the engine’s manufacturer service centre to reset the combustion mixture if necessary.

Page 5 of the Honda ESE 604 user manual — GB
Pagina 5 · klik om te vergroten
Pagina 5
  • USING THE GENERATOR SET (7.2): NOTE: This generator set has been built to current standards and designed to satisfy a wide range of applications. Remember however that every application is subject to strict electrical, accident prevention and sanitary standards. For this reason the generator set should be considered as an integral part of a system that should be designed, tested and approved by qualified technicians and/or companies.
  • In order to avoid electrical accidents, all connections to the distribution panel must be carried out by qualified technicians. Incorrect connections can harm people and damage the generator set.
  • Protection against indirect contacts: all the generator sets, during normal working, follow the law of electrical separation. However, they can be supplied with various protection options (ELCB, isometer) by the manufacturer upon specific request, or they can be protected in the same way during installation by the user. It is therefore important to follow the following instructions: 1) Standard generator set: protected by electrical separators. This equipment has a thermal protection device and/or a magnetothermal device to protect against overload, over-current and short-circuit. In these cases the generator set should under no circumstances be grounded using the terminal “PE” or with any other part of the generator set. 2) Generator set with optional switchboard (or with other devices installed by the user): protected by a circuit breaker which automatically cuts off the power supply. It has thermal circuit breaker and/or magnetothermal switches combined with differential circuit breakers or insulation monitors. In this case the generator must be connected to a ground plate through the terminal “PE”, via an insulated yellow-green conductor with a suitable section. WARNING: in the event of differential circuit breakers installation, it is important for its correct operation that: A) On single-phase generator sets the neutral point that corresponds to the joint of the two main windings is also grounded. B) On three-phase generator sets the neutral point that corresponds to the star point in the case of a star connection is also grounded. In the case of a delta connection it is not possible to install a differential switch.
  • The generator set is preset for grounding the masses; a special screw, marked with the symbol PE, allows all the metal parts of the generator set to be connected to a ground plate.
  • Do not connect to the generator set any appliances with unknown electrical specifications or with specifications different from those of the generator set (i.e. different voltages and/or frequencies).
  • The electrical circuit of the generator set is protected by a switch, which is either magnetothermal, magnetothermal-differential or thermal type. In case of overload and/or a short-circuit the power will be cut immediately. To reset the power, disconnect all appliances, check the cause of the short-circuit and/or overload and reset the switch.
  • If using the generator set as battery charger (where available), place the battery at a distance of 1 m from the generating set, making sure that the filler plugs are removed from the cells. Take care to observe the battery polarities, incorrect connection of positive and negative poles could cause the battery to explode. WARNING: During charging, the battery gives off inflammable vapour. Therefore observe the maximum caution while charging and keep children far away.
  • With a star-delta switch the following options are available: THREE PHASE 4OO V (full design load) SINGLE PHASE 230 V (1/3 of design load) THREE PHASE 230V (full design load) SINGLE PHASE 230 V (2/3 of design load) When set on “O” all power points are disconnected.
  • Before setting the switch to any of the above, make sure that no appliances are connected to the generator set. Be sure to set the switch to the correct current as shown on the tag, in order to avoid damages to the appliances. - When the generator set is in use, do not place any objects on the frame or directly on the engine: any foreign bodies may jeopardize its performance.
  • Do not hinder the normal vibrations that the generator set makes when in use. The silent-blocks are of an adequate size to work properly.

MOTOR WELDING SET SECTION Connect the welding sockets through cables of a suitable cross section -refer to table 1. Choose the right polarity according to the type of electrode to be used -refer to the electrode manufacturer’ s instructions. Open the accelerator handle in order to obtain the right welding current according to the rpm. By turning it clockwise the rpm is increased, thus increasing also the welding current. By turning the accelerator handle anticlockwise the rpm is reduced, thus reducing also the welding current.

DOUBLE POSITIVE TERMINAL When using electrodes of diameter 3.25 mm or lower place the clamp on the positive “Max 140A” terminal. When using electrodes of diameter above 3.25 mm place the clamp on the positive “Max power” terminal. This allows better welding arc quality. When using cellulose electrodes, it is advisable to keep the clamp on the + 140 terminal also for diameters above 3.25 mm.

TABLE 1 Minimum recommended section for welding cables Length Welding current 30 – 100 A 100 – 200 A 200 – 300 A 0 – 15 m 25 mmq 35 mmq 50 mmq 15 – 30 m 25 mmq 50 mmq 70 mmq 30 – 60 m 35 mmq 70 mmq 90 mmq

Page 6 of the Honda ESE 604 user manual — GB
Pagina 6 · klik om te vergroten
Pagina 6

STOPPING THE GENERATOR (8.4): Switch off or disconnect all the accessories powered by the generator: then stop the engine after letting it idle for 2-3 minutes to cool down. To stop the generator do as follows: 1) Honda engine model: turn the key to the “OFF” position 2) Yanmar engine models: Position the accelerator handle on the engine (see fig. 7) back upwards. Wait until the engine is completely off. Turn the key to the “OFF” position. 3) Ruggerini engine models: Pull the knob placed on the control panel (see fig. 8). Wait until the engine is completely off. Turn the key to the “OFF” position.

Honda ESE 604 — GB diagram (page 6)
Afb. 9

Fig.7 Fig.8

MAINTENANCE (9.1): As regards this important paragraph please carefully refer to the operation and maintenance manual published by the manufacturers of the engine: if you spend some time now you will save money later!

  • Routine battery, alternator and frame maintenance operations are reduced to a minimum: keep the battery terminals well greased and top up with distilled water when the cells are uncovered.
  • No special maintenance operations are required for the commutator system – brush holder – brushes – as they are designed to guarantee reliable and long-life performace.

Silencer Silent-Blocks Air filter Mounting of mechanical parts Engine and alternator fans Good working order of the machine Sound absorbing and sound insulating materials (where present)

If a problem arises in one or more of these components, the nearest authorized service centre should be contacted.

NOTE: When disposing of used oil or residual fuel, respect the environment. We suggest collecting waste product in drums for delivery at a later date to a nearby Service Station. Do not deposit oil and residual fuel into the earth or into unsuitable receptacles. NOTE: Bad operation of the generator set due to faults in the engine (oscillation, low number of revs, etc.) is of exclusive competence of the departments of the engine manufacturers’ customer service, both during and after the warranty period. Tampering or intervention carried out by personnel unauthorized by the manufacturers will invalidate the conditions of warranty. Malfunction of the generator set due to faults in the electrical circuits and in the frame is of exclusive competence of the manufacturers’ customer service department. Repairs carried out by unauthorized personnel, substitution of components with unoriginal spare parts and tampering with the generator will invalidate the conditions of warranty. The manufacturers refuse any liability arising out of faults or accidents due to neglect, incapacity or installation by not qualified technicians.

CLEANING (10.1): Turn off the machine and wait until the hot parts have cooled down before proceeding. It is recommended that the machine not be cleaned with jets of water or inflammable products. Use special products or a damp cloth if necessary; in the latter case pay attention to the electrical components. Before turning the machine back on make sure that it is completely dry.

TRANSPORTATION (11.1): • It is a good rule during transportation to firmly fix the generator set so that it cannot turn over; remove all fuel and make that acid or fumes do not leak from the battery (if present). Check the overall weight of the machine to be transported by road. Under no circumstances should the generator set be started while inside a truck.

  • STORAGE (12.1): If you do not intend to use the generator set for more than thirty days, it is advisable to completely drain the fuel tank. For petrol engines it is important to drain also the carburettor float chamber: petrol left in contact with components for a long period will cause them to deteriorate due to the rubber deposits typical to this fuel. WARNING: Petrol is extremely inflammable and explosive under certain conditions. Avoid smoking and sparks in the vicinity.
  • Change the engine oil, if it is exhausted. When the engine is not in use, it could damage the thermal group and the connecting rods.
  • Clean the generator accurately, disconnect the battery cables (if present) and cover it to protect it from dust and damp.
Page 7 of the Honda ESE 604 user manual — THE ENGINE DOES NOT START (15.1):
Pagina 7 · klik om te vergroten
Pagina 7

TROUBLE SHOOTING:

NO VOLTAGE IN A.C. SOCKET (13.1):

Honda ESE 604 — NO VOLTAGE IN A.C. SOCKET (13.1): diagram (page 7)
Afb. 10

IS THE REQUIRED VOLTAGE SELECTED ON THE SWITCH? ⊗ ACTIVER

IS THERE ALWAYS LACK OF VOLTAGE WHEN THE CONDENSER HAS BEEN ENERGIZED AT THE CONNECTORS WITH A 12V BATTERY? ⊗⊗ GENERATOR OK

TROUBLE SHOOTING (MOTOR WELDING SET SECTION) NO VOLTAGE IN A.C. SOCKET AND/OR WELDING SOCKETS (14.2):

Honda ESE 604 — NO VOLTAGE IN A.C. SOCKET (13.1): diagram (page 7)
Afb. 11

THE ENGINE DOES NOT START (15.1):

Honda ESE 604 — THE ENGINE DOES NOT START (15.1): diagram (page 7)
Afb. 12

IS THERE ANY FUEL IN THE TANK? FILL TANK

IS THERE AIR IN THE FEEDING CIRCUIT? ⊗⊗ ELIMINATE

⊗ ONLY WHEN FORESEEN ⊗⊗ ONLY FOR DIESEL ENGINE ⊗⊗⊗ ONLY FOR EXPLOSION ENGINE

Page 8 of the Honda ESE 604 user manual — TROUBLE SHOOTING:
Pagina 8 · klik om te vergroten
Pagina 8
Page 8 of the Honda ESE 604 user manual — TROUBLE SHOOTING:

Vraag stellen over de Honda ESE 604

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Honda ESE 604

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Honda ESE 604 handleiding-pdf

80 pagina's·1.6 MB·Generator·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…