Page 1 of the Topcom 2300 user manual — USER GUIDE HANDLEIDING MODE D’EMPLOI BEDIENUNGSANLEITUNG
Pagina 1 · klik om te vergroten
Pagina 1

BPM Wrist 2300

Topcom 2300 — BPM Wrist 2300 diagram (page 1)
Afb. 1 · BPM Wrist 2300

USER GUIDE HANDLEIDING MODE D’EMPLOI BEDIENUNGSANLEITUNG

ANVÄNDARHANDBOK

BRUGSANVISNING ANVÄNDARHANDBOK

KÄYTTÖOHJE

Page 2 of the Topcom 2300 user manual — BPM Wrist 2300
Pagina 2 · klik om te vergroten
Pagina 2

Exclusively produced for Topcom Europe NV,

Grauwmeer 17, 3001 Heverlee, Belgium

by Rossmax Int’l Ltd. N° 6018 Huyi Rd., Waigang, Jiading District,

This product is in compliance with the essential requirements and other relevant provisions of the

93/42/EEC and 89/336/EEC directive. The Declaration of conformity can be found on: http://www.topcom.net/support/cedeclarations.php

GB The features described in this manual are published with reservation to modifications.

NL De in deze handleiding beschreven mogelijkheden worden gepubliceerd onder voorbehoud van wijzigingen.

F Les possibilités décrites dans ce manuel sont publiées sous réserve de modifications.

D Die in dieser Bedienungsanleitung umschriebenen Möglichkeiten, werden vorbehaltlichÄnderungen publiziert.

S Funktionerna i denna bruksanvisning publiceras med reservation för ändringar.

DK Vi forbeholder os retten til ændringer af de specifikationer, der er beskrevet i denne brugsanvisning.

N Funksjoner beskrevet i denne manualen kan endres uten nærmere informasjon.

SF Tässä ohjekirjassa julkaissut tiedot voivat muuttua ilman ennakkoilmoitusta.

Shanghai China 201806

Page 3 of the Topcom 2300 user manual — BPM Wrist 2300
Pagina 3 · klik om te vergroten
Pagina 3

1 Introduction 4 2 Safety instructions 4 3 Technical specifications 5 4 Helpfull tips 5 5 Disposal of the device (environment) 6 6 Blood pressure 6 6.1 What is Blood Pressure? 6 6.2 Why Measure Your Blood Pressure? 6 6.3 Blood Pressure Standard 7 6.4 Blood Pressure Fluctuation 7 7 Battery installation 8 8 Buttons 8 9 Display 9 10 Applying the cuff 10 11 Measuring posture 11 12 Measurement 11 12.1 Important 11 12.2 Procedure 12 13 Memory 13 14 Warranty 14 14.1 Warranty period 14 14.2 Warranty handling 14 14.3 Warranty exclusions 14

The CE symbol indicates that the unit complies with the essential

requirements of the directive 93/42/EEC and 89/336/EEC.

Page 4 of the Topcom 2300 user manual — 2 SAFETY INSTRUCTIONS
Pagina 4 · klik om te vergroten
Pagina 4

1 INTRODUCTION

Congratulations with your purchase of the Topcom BPM wrist 2300. This fully automatic, wrist mounted blood pressure monitor is both easy to use and ideally suited for daily measurements. The large display includes systolic, diastolic and pulse, all clearly shown at the completion of each reading. In addition, you can store up to 30 measurements per Memory Zone, ideal for users who want to monitor and track their blood pressure on a regular basis. The BPM wrist 2300 is compact and portable, making it ideal for home use and travel.

Please read this manual carefully before use. For specific information on your own blood pressure, contact your physician. Put the user guide away in a safe place for future reference.

2 SAFETY INSTRUCTIONS

1. This product is for household use only. Is is not intended as a substitute for consultation with your doctor. 2. For users diagnosed with common arrhythmia (atrial or ventricular premature beats or atrial fibrillation), diabetes, poor circulation of blood, kidney problems, or for users suffered from stroke, or for unconscious users, the device might not be suitable for use. Consult your doctor in case of any doubt. 3. The unit should not be operated by children so to avoid hazardous situations. 4. The unit contains high-precision assemblies. Therefore, avoid extreme temperatures, humidity, and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it from dust. 5. Leaky batteries can damage the unit. Remove the batteries when the unit is not used for a long time. 6. Do not press the START key when the cuff is not placed around the wrist. 7. Do not disassemble the main unit or cuff. 8. If the unit is stored in a cold place, allow it to acclimate at room temperature before use. 9. Clean the blood pressure monitor body and the cuff carefully with a slightly damp, soft cloth. Do not press. Do not bend the pre-formed cuff inside out. Do not wash the cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner. 10. To ensure accurate measurements, it is recommended that calibration be completed every two years.

Page 5 of the Topcom 2300 user manual — 4 HELPFULL TIPS
Pagina 5 · klik om te vergroten
Pagina 5

3 TECHNICAL SPECIFICATIONS

Power source Measurement method Measurement zone

3V DC: 2 LR03 (AAA)non-rechargeable batteries Oscillometric Pressure: 20~280 mmHg Pulse: 40~180 beats/minute Pressure: ±3 mmHg Pulse: within ±5% of reading Semi-conductor Pump driven Automatic Pressure release valve 30 memories for each zone 30 seconds after last key operation : 10°C~40°C(50°F~104°F) 40~85% RH max. -5°C~60°C (23°F~140°F) 10~95% RH max. 115g (without batteries) 13.5~19.5cm(5.3”~7.7”) Over 18 years old 81(L) x 78(W) x 78(H) mm Short time operation 3 minutes. Classification of type BF

Pressure sensor Inflation Deflation Memory capacity Auto-shut-off Operation environment

Weight Wrist circumference Limited patient Dimensions K.B. Classification

*Specifications are subject to change without notice.

4 HELPFULL TIPS

Here are a few helpful tips to help you obtain more accurate readings:

  • Do not measure your blood pressure immediately after consuming a large meal. To obtain more accurate readings, please wait one hour before measuring.
  • Do not smoke or drink alcohol before measuring your blood pressure.
  • You should not do be physically tired or exhausted while taking a measurement.
  • It is important that you relax during measurement. Try to take 15minutes rest before a reading.
  • Do not take measurements if you are under stress or under tension.
  • Take your blood pressure at normal body temperature. If you are feeling cold or hot, wait a while before taking a measurement.
  • If the monitor is stored at very low temperature (near freezing), have it placed at a warm location for at least one hour before using it.
  • Wait about 5 minutes before taking the next pressure measurement.

Accuracy · Storage environment

Page 6 of the Topcom 2300 user manual — 6.2 WHY MEASURE YOUR BLOOD PRESSURE?
Pagina 6 · klik om te vergroten
Pagina 6

5 DISPOSAL OF THE DEVICE

(ENVIRONMENT)

At the end of the product lifecycle, you should not throw this product into the normal household garbage but bring the product to a collection point for the recycling of electrical and electronic equipments. The symbol on the product, user guide and/or box indicate this. Some of the product materials can be re-used if you bring them to a recycling point. By re-using some parts or raw materials from used products you make an important contribution to the protection of the environment. Please contact your local authorities in case you need more information on the collection points in your area.

6 BLOOD PRESSURE

6.1 WHAT IS BLOOD PRESSURE?

Blood pressure is the pressure exerted on the artery tube while blood flows through the arteries. The pressure measured when the heart contracts and sends blood out of the heart is systolic (highest). The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic (lowest) blood pressure.

6.2 WHY MEASURE YOUR BLOOD PRESSURE?

Among the various health problems afflicting modern people, problems associated with high blood pressure are by far the most common. High blood pressure's dangerously strong correlation with cardiovascular diseases and high morbidity has made measuring blood pressures a necessity of identifying those at risk.

Page 7 of the Topcom 2300 user manual — 6.4 BLOOD PRESSURE FLUCTUATION
Pagina 7 · klik om te vergroten
Pagina 7

6.3 BLOOD PRESSURE STANDARD

The World Health Organization (WHO) has developed a Blood pressure standard, according to which areas of low and high-risk blood pressure are identified. This standard, however, is a general guideline as individual's blood pressure varies among different people and different groups...etc.

Hypertension Systolic over 160 Diastolic over 95 95 (mmHg)! Borderline Systolic 140 ~159 Diastolic 90 ~ 94 90 Hypotension Normal Diastolic Systolic Systolic under 139 under 99 Diastolic under 89 100 140 160 Systolic (mmHg) !Hypertension Systolic over 160 Diastolic over 95 Borderline Systolic 140 ~159 Diastolic 90 ~ 94 Hypotension Normal Systolic Systolic under 139 under 99 Diastolic under 89 Borderline Systolic 140 ~159 Diastolic 90 ~ 94 Hypotension Normal Systolic Systolic under 139 under 99 Diastolic under 89 Hypotension Systolic under 99Normal Systolic under 139 Diastolic under 89

It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk.

6.4 BLOOD PRESSURE FLUCTUATION

Blood pressure fluctuates all the time! You should not be worried if you encountered two or three measurements at high levels. Blood pressure changes over the month and even throughout the day depending on circumstances (state of mind, temperature, ...)

Ex. Fluctuation within the day for a Male, 35 years old.

18u 24u 12u 6u

200 mmHg · Systolic · Diastolic

Page 8 of the Topcom 2300 user manual — 8 BUTTONS
Pagina 8 · klik om te vergroten
Pagina 8

7 BATTERY INSTALLATION

  • Open the battery compartiment by sliding the cover away
  • Insert 2 AAA batteries (LR03). Follow the polarity as indicated in the battery compartiment.

Do not shortcircuit and dispose of in fire. Remove the battery if this device is not going to be used for a long period.

8 BUTTONS

1. Wrist Cuff
2. Recall key for memory 1
3. On/Start Key 1
4. On/Start Key 2
5. Recall Key for memory 2
6. Battery cover
7. LCD Display
Page 9 of the Topcom 2300 user manual — 9 DISPLAY
Pagina 9 · klik om te vergroten
Pagina 9

9 DISPLAY

1. Systolic pressure
2. Diastolic pressure
3. Pulse rate
4. Sequence
5. Battery Low indicator
6. Stored in Memory Zone 2
7. Stored in Memory Zone 1
Page 10 of the Topcom 2300 user manual — 10 APPLYING THE CUFF
Pagina 10 · klik om te vergroten
Pagina 10

10 APPLYING THE CUFF

Topcom 2300 — 10 APPLYING THE CUFF diagram (page 10)
Afb. 2
1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor.Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements.Apply cuff to left wrist with palm facing up.
2. Make sure the edge of the cuff is about 1 cm from the palm.In order to insure accurate-measurements.
3. Fasten the velcro strap securely around your wrist so there is no extra space between the cuff and the wrist. If the cuff is not wrapped tight enough,the measurement values will be false.
4. If your physician has diagnosed you with poor circulation on your leftarm, place the cuff around your right wrist.
Page 11 of the Topcom 2300 user manual — 12.1 IMPORTANT
Pagina 11 · klik om te vergroten
Pagina 11

11 MEASURING POSTURE

1. Relax your entire body,especially the area between your elbow and fingers. Place your elbow on a table so that the cuff is at the same level as your heart.

Your heart is located slightly below your arm pit.

2. If the cuff is not at the same level as your heart or if you can not keep your arm completely still throughout the reading, use a soft object such as folded towel to support your arm.

(X)

3. Turn your palm upwards.Sit upright in a chair, and take 5-6 deep breaths. Avoid leaning back while the measurementis being taken.

12 MEASUREMENT

12.1 IMPORTANT

1. This monitor automatically switches off 30 seconds after the last key operation. 2. To interrupt the measurement, simply press any key. The cuff will deflate immediately after a key is pressed. 3. During the measurement, do not talk or move your arm or hand muscles.
Page 12 of the Topcom 2300 user manual — 12.2 PROCEDURE
Pagina 12 · klik om te vergroten
Pagina 12

12.2 PROCEDURE

Topcom 2300 — 12.2 PROCEDURE diagram (page 12)
Afb. 3
1. Press On/Start Key 1 if you want to make use of Memory Zone 1, or

Press On/Start Key 2 if you want to make use of Memory Zone 2.

All digits will light up for 2 seconds.

2. After all symbols appear, the display will show a blinking"0" with the designated Memory Zone. At this time,the monitor is "Ready to Measure".
3. The monitor automatically inflates the cuff to approximately 180 mmHg, measurement will begin.
Topcom 2300 — 12.2 PROCEDURE diagram (page 12)
Afb. 4

This monitor will re-inflate automatically to approximately 220mmHg if the system detects that your body needs more pressure to measure your blood pressure.

4. When the measurement is completed, systolic, diastolicand pulse will be shown simultaneously and be saved automatically in the memory system according to the designated Memory Zone. Up to 30 measurements can be saved per Memory Zone.

When a mistake was detected during measurement the Error mark appears on the display

Page 13 of the Topcom 2300 user manual — 13 MEMORY
Pagina 13 · klik om te vergroten
Pagina 13

13 MEMORY

  • Press M1 to recall values from Memory Zone 1.
  • Press M2 to recall values from Memory Zone 2.
Topcom 2300 — 13 MEMORY diagram (page 13)
Afb. 5

All stored measurements will be assigned distinct numbers, identifying the sequence in which the values are stored. The last measurement will be shown first. Every new press of the Recall Key calls for one prior value stored.

Topcom 2300 — 13 MEMORY diagram (page 13)
Afb. 6

When the batteries are installed, the data in the memories will not be lost even when the Blood Pressure Monitor is switched off. Remove the batteries for more than 10 seconds to erase the mem- ories.

Page 14 of the Topcom 2300 user manual — 14.3 WARRANTY EXCLUSIONS
Pagina 14 · klik om te vergroten
Pagina 14

14 WARRANTY

14.1 WARRANTY PERIOD

The Topcom units have a 24-month warranty period. The warranty period starts on the day the new unit is purchased. The warranty on batteries is limited to 6 months after purchase. Consumables or defects causing a negligible effect on operation or value of the equipment are not covered. The warranty has to be proven by presentation of the original purchase receipt, on which the date of purchase and the unit-model are indicated.

14.2 WARRANTY HANDLING

A faulty unit needs to be returned to a Topcom service centre including a valid purchase note. If the unit develops a fault during the warranty period, Topcom or its officially appointed service centre will repair any defects caused by material or manufacturing faults free of charge. Topcom will at its discretion fulfil its warranty obligations by either repairing or exchanging the faulty units or parts of the faulty units. In case of replacement, colour and model can be different from the original purchased unit. The initial purchase date shall determine the start of the warranty period. The warranty period is not extended if the unit is exchanged or repaired by Topcom or its appointed service centres.

14.3 WARRANTY EXCLUSIONS

Damage or defects caused by incorrect treatment or operation and damage resulting from use of non-original parts or accessories not recommended by Topcom are not covered by the warranty. The warranty does not cover damage caused by outside factors, such as lightning, water and fire, nor any damage caused during transportation. No warranty can be claimed if the serial number on the units has been changed, removed or rendered illegible.

Vraag stellen over de Topcom 2300

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Topcom 2300

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Topcom 2300 handleiding-pdf

100 pagina's·1.3 MB·Bloeddrukmeter·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…